SIEMENS - 3VT1 (to 160 A) to 25 kA

Image
Part Number
Description
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION OVERCURRENT RELEASE TM, LI IN= 16A RATED CURRENT IR= 12.5... 16A OVERLOAD PROT. II= 160... 240A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITH TERMINALS F.FRONT CONNECT.
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 16A RATED CURRENT IR= 12.5... 16A OVERLOAD PROT. II= 160... 240A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, MOTOR PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 16A RATED CURRENT IR= 12.5... 16A OVERLOAD PROT. II= 160A, SHORT-CIRC. PROT. W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 16A RATED CURRENT IR= 12.5... 16A OVERLOAD PROT. II= 160... 240A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/O PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LIN IN= 16A RATED CURRENT IR= 12.5... 16A OVERLOAD PROT. II= 160... 240A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 20A RATED CURRENT IR= 16... 20A OVERLOAD PROT. II= 200... 300A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, MOTOR PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 20A RATED CURRENT IR= 16... 20A OVERLOAD PROT. II= 200A, SHORT-CIRC. PROT. W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 20A RATED CURRENT IR= 16... 20A OVERLOAD PROT. II= 200... 300A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/O PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LIN IN= 20A RATED CURRENT IR= 16... 20A OVERLOAD PROT. II= 200... 300A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 32A RATED CURRENT II= 160... 320A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 32A RATED CURRENT IR= 25... 32A OVERLOAD PROT. II= 160... 320A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, MOTOR PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 32A RATED CURRENT IR= 25... 32A OVERLOAD PROT. II= 320A, SHORT-CIRC. PROT. W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 32A RATED CURRENT II= 160... 320A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/O PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 32A RATED CURRENT IR= 25... 32A OVERLOAD PROT. II= 160... 320A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/O PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 32A RATED CURRENT II= 160... 320A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LIN IN= 32A RATED CURRENT IR= 25... 32A OVERLOAD PROT. II= 160... 320A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 40A RATED CURRENT IR= 40A OVERLOAD PROTECTION II= 160A, SHORT-CIRC. PROT. W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 40A RATED CURRENT II= 200... 400A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 40A RATED CURRENT IR= 32... 40A OVERLOAD PROT. II= 200... 400A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, MOTOR PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 40A RATED CURRENT IR= 32... 40A OVERLOAD PROT. II= 400A, SHORT-CIRC. PROT. W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 40A RATED CURRENT IR= 40A OVERLOAD PROTECTION II= 160A, SHORT-CIRC. PROT. N CONDUCTOR W/O PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 40A RATED CURRENT II= 200... 400A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/O PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 40A RATED CURRENT IR= 32... 40A OVERLOAD PROT. II= 200... 400A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/O PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 40A RATED CURRENT II= 200... 400A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LIN IN= 40A RATED CURRENT IR= 40A OVERLOAD PROTECTION II= 160A, SHORT-CIRC. PROT. N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LIN IN= 40A RATED CURRENT IR= 32... 40A OVERLOAD PROT. II= 200... 400A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 50A RATED CURRENT IR= 50A OVERLOAD PROTECTION II= 200A, SHORT-CIRC. PROT. W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 50A RATED CURRENT II= 250... 500A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 50A RATED CURRENT IR= 40... 50A OVERLOAD PROT. II= 250... 500A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, MOTOR PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 50A RATED CURRENT IR= 40... 50A OVERLOAD PROT. II= 500A, SHORT-CIRC. PROT. W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Menu
Mail Us
enquiry@onstocktrading.com