CIRCUIT-BREAKER VL 1250L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT LCD ETU40, LI/LS/LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED
CIRCUIT-BREAKER VL 1250L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT LCD ETU42, LSIG 3PHASES/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT
CIRCUIT-BREAKER VL 1250L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT LCD ETU42, LSIG 3PHASES/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE
CIRCUIT-BREAKER VL 1250L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT
CIRCUIT-BREAKER VL 1250L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE
CIRCUIT-BREAKER VL 1250L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT LCD ETU42, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/3 WIRES IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU42, LSIG IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED WITH EARTH FAULT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR/GENERATOR PROT. LCD ETU40M, LI IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/3 WIRES IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU42, LSIG IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED WITH EARTH FAULT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR/GENERATOR PROT. LCD ETU40M, LI IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/3 WIRES IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU42, LSIG IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED WITH EARTH FAULT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR/GENERATOR PROT. LCD ETU40M, LI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT