SIEMENS - 3VL

Image
Part Number
Description
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR/GENERATOR PROT. ETU10M, LI IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR PROTECTION ETU30M, LI IR= 64...160A, OVERLOAD PROTECTION, TC= 10A ... 30, TIME LAG CLASS II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU10, LI IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU10, LI IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU20, LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N UNPROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU20, LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU22, LSIG IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU12, LIG IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/3 WIRES IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU42, LSIG IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED WITH EARTH FAULT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR/GENERATOR PROT. LCD ETU40M, LI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
OVERCURRENT RELEASE VL 160 3-POLE, SYSTEM PROTECTION THERMO-MAGNETIC, LI IR= 125...160 A, OVERLOAD PROTECTION
OVERCURRENT RELEASE VL 160 3-POLE, STARTER COMBINATION II= 1250...2500 A, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREW
OVERCURRENT RELEASE VL 160 4-POLE, SYSTEM PROTECTION THERMO-MAGNETIC, LI IR= 125...160A, OVERLOAD PROTECTION,
WYZW. NADPR. VL 160, 4 P, DO OCHRONY SYST., TERMO-MAGN., FUNKCJE LI IR=125...160A, OCHRONA ZWARC.II= 800...1600 A, OCHR.'N'(100%),ZACISKI RAMOWE/PRZYŁ. ŚRUB. W ZAKRESIE ZAMÓWIENIA WYŁĄCZNIKA
ACCESSORY FOR VL160, CURRENT TRANSFORMER FOR OVERLOAD PROTECTION OF THE N-CONDUCTOR AND FOR EARTH-FAULT PROTECTION IN=125A/160A
ACCESSORY FOR VL150UL, (DG-FRAME) BOX TERMINALS COMPRISING 3 BOX TERMINALS 3-POLE
ACCESSORY FOR VL150UL (DG-FRAME) LUG CONNECTIONS 1 SET = 3 UNITS CAT NUMBER 3CLD20
ACCESSORY FOR VL160 BOX TERMINALS COMPRISES 3 BOX TERMINALS AND TERMINAL COVER 3-POLE
ACCESSORY FOR VL150UL, (DG-FRAME) ROUND CONDUCTOR TERMINAL FOR CU/AL COMPRISING 3 TERMINALS 3-POLE ONLY FOR 60 - 150 A CAT NUMBER 3TA1DG30
ACCESSORY FOR VL160, CURRENT TRANSFORMER FOR OVERLOAD PROTECTION OF THE N-CONDUCTOR AND FOR EARTH-FAULT PROTECTION IN=63A/80A
ACCESSORY FOR VL150XUL- VL250UL (CG-FRAME - FG-FRAME) KIT F. LEADING AUXILIARY SWITCHES, MAXFLEX 1 CO CONTACTS 1.5 METER CONNECTING CABLE
ACCESSORY FOR VL150XUL- VL250UL (CG-FRAME - FG-FRAME) KIT F. LEADING AUXILIARY SWITCHES, MAXFLEX 2 CO CONTACTS 1.5 METER CONNECTING CABLE
ACCESSORY FOR VL160X, VL160, VL250, KIT F. LEADING AUXILIARY SWITCHES 1 CO CONTACT, FROM OFF TO ON 1.5 METER CONNECTING CABLE
ACCESSORY FOR VL150XUL- VL250UL (CG-FRAME - FG-FRAME) KIT F. LEADING AUXILIARY SWITCHES 1 CO CONTACT, FROM OFF TO ON 1.5 METER CONNECTING CABLE
ACCESSORY FOR VL160X, VL160, VL250, KIT F. LEADING AUXILIARY SWITCHES 2 CO CONTACTS, FROM OFF TO ON 1.5 METER CONNECTING CABLE
ACCESSORY FOR VL150XUL- VL250UL (CG-FRAME - FG-FRAME) KIT F. LEADING AUXILIARY SWITCHES 2 CO CONTACTS, FROM OFF TO ON 1.5 METER CONNECTING CABLE