SIEMENS - 3VL

Image
Part Number
Description
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR PROTECTION ETU30M, LI IR= 40...100A, OVERLOAD PROTECTION, TC= 10A ... 30, TIME LAG CLASS II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU10, LI IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU10, LI IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU20, LSI IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N UNPROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU20, LSI IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU22, LSIG IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION ETU12, LIG IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU40, LI/LS/LSI IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/3 WIRES IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION LCD ETU42, LSIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 4-POLE, SYSTEM PROTECTION LCD ETU42, LSIG IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED WITH EARTH FAULT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR/GENERATOR PROT. LCD ETU40M, LI IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
OVERCURRENT RELEASE VL 160 3-POLE, SYSTEM PROTECTION THERMO-MAGNETIC, LI IR= 80...100 A, OVERLOAD PROTECTION
OVERCURRENT RELEASE VL 160 3 POLE, STARTER COMBINATION II= 750...1200 A, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREW
OVERCURRENT RELEASE VL 160 4-POLE, SYSTEM PROTECTION THERMO-MAGNETC, LI IR= 80...100 A, OVERLOAD PROTECTION,
WYZW. NADPR. VL 160, 4 P, DO OCHRONY SYST., TERMO-MAGN., FUNKCJE LI IR=80...100A, OCHRONA ZWARC.II= 500...1000A, OCHR. 'N', ZACISKI RAMOWE/PRZYŁ. ŚRUB. W ZAKRESIE ZAMÓWIENIA WYŁĄCZNIKA
ACCESSORY FOR VL160, CURRENT TRANSFORMER FOR OVERLOAD PROTECTION OF THE N-CONDUCTOR AND FOR EARTH-FAULT PROTECTION IN=100A
OVERCURRENT RELEASE VL 160 3-POLE, SYSTEM PROTECTION THERMO-MAGNETC, LI IR= 100...125 A, OVERLOAD PROTECTION
OVERCURRENT RELEASE VL 160 4-POLE, SYSTEM PROTECTION THERMO-MAGNETC, LI IR=100...125 A, OVERLOAD PROT., II= 625...1250 A,
OVERCURRENT RELEASE VL 160 4-POLE, SYSTEM PROTECTION THERMO-MAGNETC, LI IR= 100...125 A, OVERLOAD PROTECTION,
OVERCURRENT RELEASE VL 160 4-POLE, SYSTEM PROTECTION THERMO-MAGNETC, LI IR=100...125A, OVERLOAD PROT., II= 625...1250 A,
ACCESSORY FOR VL160 CIRCULAR COND. TERMINAL COMPRISES 3 CIRC. CONDUCTOR TERMINALS AND TERMINAL COVER 3-POLE
ACCESSORY FOR VL160, CIRCULAR COND. TERMINAL COMPRISES 3 CIRC. CONDUCTOR TERMINALS AND TERMINAL COVER 3-POLE
ACCESSORY FOR VL160, CIRCULAR COND. TERMINAL COMPRISES 4 CIRC. CONDUCTOR TERMINALS AND TERMINAL COVER 4-POLE
ACCESSORY FOR VL160X,VL160, CONNECTION BARS ON FRONT CONSISTS OF 3 CONNEC FOR SWITCH CONNECTION M6, 3-POLE
ACCESSORY FOR VL160X,VL160, CONNECTION BARS ON FRONT CONSISTS OF 4 CONNEC FOR SWITCH CONNECTION M6, 4-POLE
ACCESSORY FOR VL160X,VL160, CONNECTION BARS ON FRONT INCREASED POLE SPACING CONSISTS OF 3 CONNEC SWITCH CONNECTION M6 3-POLE
ACCESSORY FOR VL160X,VL160, CONNECTION BARS ON FRONT INCREASED POLE SPACING CONSISTS OF 4 CONNEC, SWITCH CONNECTION M6, 4-POLE
ACCESSORY FOR VL160, SCREW TERMINAL METRIC THREAD M6 COMPRISING 3 TERMINALS