WYZW. NADPR. VL 160, 4 P, DO OCHRONY SYST., TERMO-MAGN., FUNKCJE LI IR=40...50A, OCHRONA ZWARC.II= 250...500A, OCHR. 'N', ZACISKI RAMOWE/PRZYŁ. ŚRUB. W ZAKRESIE ZAMÓWIENIA WYŁĄCZNIKA
ELECTRONIC TRIP UNIT VL 160 4-POLE, PLANT PROTECTION ETU10, LI IR= 26...63A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION, N-PROTECTED BOX TERMINALS/SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 160 3-POLE, PLANT PROTECTION ETU10, LI IR= 26...63A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 160 3-POLE, PLANT PROTECTION ETU20, LSI IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 160 4-POLE, PLANT PROTECTION ETU20, LSI IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION, N-PROTECTED BOX TERMINALS/SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR PROTECTION ETU30M, LI IR= 26...63A, OVERLOAD PROTECTION, TC= 10A ... 30,TIME LAG CLASS II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION ETU20, LSI IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION ETU12, LIG 3 PHASES/3 WIRES IR= 26...63A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION ETU22, LSIG 3 PHASES/3 WIRES IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION ETU22, LSIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 26...63A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, SYSTEM PROTECTION ETU12, LIG 3 PHASES/3 WIRES IR= 26...63A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 160 3-POLE, MOTOR/GENERATOR PROT. ETU10M, LI IR= 26...63A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT