SIEMENS - 3RV19 Circuit Breaker MCCB 3RV

Image
Part Number
Description
MOLDED CASE CIRC.BREAKER 3RV1 FOR MOTOR PROTECTION STANDARD SWITCHING CAPACITY RATED CURRENT IN=100A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 6-13XLN OVERLOAD PROTECTION UEL 0.4-1XLN, CLASS 10A-30 ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL.PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR MOTOR PROTECTION STANDARD SWITCHING CAPACITY RATED CURRENT IN=160A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 6-13XLN OVERLOAD PROTECTION UEL 0.4-1XLN, CLASS 10A-30 ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR MOTOR PROTECTION STANDARD SWITCHING CAPACITY RATED CURRENT IN=200A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 6-13XLN OVERLOAD PROTECTION UEL 0.4-1XLN, CLASS 10A-30 ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR MOTOR PROTECTION STANDARD SWITCHING CAPACITY RATED CURRENT IN=400A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 6-13XLN OVERLOAD PROTECTION UEL 0.4-1XLN, CLASS 10A-30 ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR MOTOR PROTECTION STANDARD SWITCHING CAPACITY RATED CURRENT IN=630A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 6-13XLN OVERLOAD PROTECTION UEL 0.4-1XLN, CLASS 10A-30 ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=1A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION NON-ADJUSTABLE 13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=1.6A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION NON-ADJUSTABLE 13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=2A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION NON-ADJUSTABLE 13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIER
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=3.2A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION NON-ADJUSTABLE 13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=4A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION NON-ADJUSTABLE 13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=5A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION NON-ADJUSTABLE 13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=6.5A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION NON-ADJUSTABLE 13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=8.5A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION NON-ADJUSTABLE 13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=12.5A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION NON-ADJUSTABLE 13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=20A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 6-13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=32A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 6-13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=100A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=160A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=250A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION INCREASED SWITCHING CAPACITY RATED CURRENT IN=100A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =200KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION INCREASED SWITCHING CAPACITY RATED CURRENT IN=160A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =200KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION INCREASED SWITCHING CAPACITY RATED CURRENT IN=250A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =200KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=400A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=630A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =120KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION INCREASED SWITCHING CAPACITY RATED CURRENT IN=400A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =200KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=630A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =100KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=800A ELECTRONIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 1-10XLN ICU =100KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS
ROTARY LEVER OPER.MECHANISM WITH LOCK/DOOR INTERLOCKING FOR FRAME SIZE 3RV13 5
ROTARY LEVER OPERAT.MECHANISM WITH LOCK/DOOR INTERLOCKING FOR FRAME SIZE 3RV1. 6, 7
MOTORIZED OPERATING MECHANISM WITH SPRING ENERGY STORE 220 V...250 V AC/DC FOR FRAME SIZE 3RV1. 6, 7