SIEMENS - 1LA/1LG/1LP/1PP

Image
Part Number
Description
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 8-POLE * SIZE 71 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,12 KW 3 AC 60HZ 460VY * 0,14 KW 220-240/380-420(50);440-480(60) IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 8-POLE * SIZE 71 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,12 KW 3 AC 60HZ 460VY * 0,14 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF130 (A 160)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,75 KW 3 AC 60HZ 460VY * 0,86 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 A11 = MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,75 KW 3 AC 60HZ 460VY * 0,86 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,75 KW 3 AC 60HZ 460VY * 0,86 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,75 KW 3 AC 60HZ 460VY * 0,86 KW IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT100 (C120)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,75 KW 3 AC 60HZ 460VY * 0,86 KW IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT100 (C120) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 80 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,55 KW 3 AC 60HZ 460VY * 0,63 KW 220-240/380-420(50);440-480(60) IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 80 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,55 KW 3 AC 60HZ 460VY * 0,63 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 80 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,55 KW 3 AC 60HZ 460VY * 0,63 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 80 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,55 KW 3 AC 60HZ 460VY * 0,63 KW 220-240/380-420(50);440-480(60) IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT100 (C120)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 80 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,55 KW 3 AC 60HZ 460VY * 0,63 KW 220-240/380-420(50);440-480(60) IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT100 (C120) G26=SPRING PRESSURE BRAKE 1 AC 50HZ 230V INCLUDING MOUNTING COSTS
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 6-POLE * SIZE 80 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,37 KW 3 AC 60HZ 460VY * 0,43 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) M34=VERSION FOR ZONE 21 AND ZONE 22 WITH CONDUCTING DUST (IP65) FOR MAINS OPERATION EX TB IIIC T125 DEGREES DB
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 6-POLE * SIZE 80 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,37 KW 3 AC 60HZ 460VY * 0,43 KW 220-240/380-420(50);440-480(60) IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT100 (C120)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 6-POLE * SIZE 80 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,37 KW 3 AC 60HZ 460VY * 0,43 KW 220-240/380-420(50);440-480(60) IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT100 (C120) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL.
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT100 (C120) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW IMB14, IMV19 IMV18 W/O CANOPY SPECIAL FLANGE: C 160
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW IMB14, IMV19 IMV18 W/O CANOPY SPECIAL FLANGE: C 160 C13=ACC.TO THERM. CL. 155 (F) WITH HIGHER COOLANT TEMPERATURE (55 CEL) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) D31=TO UL WITH RECOGNITION MARK L99=SKELETON CONTAINER PACKING
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW IMB14, IMV19 IMV18 W/O CANOPY SPECIAL FLANGE: C 160 C13=ACC.TO THERM. CL. 155 (F) WITH HIGHER COOLANT TEMPERATURE (55 CEL) D31=TO UL WITH RECOGNITION MARK D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW IMB14, IMV19 IMV18 W/O CANOPY SPECIAL FLANGE: C 160 D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,75 KW 3 AC 60HZ 460VY * 0,86 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 A11 = MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,75 KW 3 AC 60HZ 460VY * 0,86 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,75 KW 3 AC 60HZ 460VY * 0,86 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 80 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,75 KW 3 AC 60HZ 460VY * 0,86 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP Only Ex version! Low-voltage motor, squirrel-cage rotor, IP55 4-pole*Size 80M* temperature class 155(F), IE1 * Aluminum housing 3 AC 50 Hz 230 VD/400 VY * 0.75 kW 3 AC 60 Hz 460 VY * 0.86 kW IM B14, IM V19 IM V18 without canopy Standard flange: FT100 (C120) B16=Motor for switching operation S6 60%
Menu
Mail Us
enquiry@onstocktrading.com