Specification: Part Number 1065352 RoHS certificate: + Connection type: Round connector M12 x 1, 5-pin UL approval: + Probe length: 3,500 mm Process pressure: -1 bar ... 16 bar Protection class: III Process temperature: -20 °C ... +150 °C MTTF: 194.3 a (EN ISO 13849-1) Capacitive load: 100 nF Signal voltage HIGH: Vs - 2 V Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Signal voltage LOW: ≤ 2 V Accuracy of sensor element: ± 5 mm Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Interference emission: EN 61000-6-4:2007 Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Power consumption: ≤ 75 mA at 24 V DC without output load Hysteresis: Min. 2 mm, free adjustable Single- and continuous shock: EN 60068-2-27 Output current: < 100 mA Inactive area at probe end: 10 mm Inactive area at process connector: 25 mm Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V EMC: EN 61326-1:2006, 2004/108/EG 3-A: - GOST approval: + Initialization time: ≤ 2 s Resolution: < 2 mm EHEDG approval: + Response time: < 400 ms Temperature drift: < 0.1 mm/K Medium: Fluids Measurement: Switch, Continuous Inductive load: < 1 H Ambient storage temperature: -40 °C ... +80 °C Interference resistance: EN 61000-6-2:2005 Lower signal level: 3.8 mA ... 4 mA Conductivity: No limitation Max.probe load: 6 Nm Ambient temperature operation: -20 °C ... +60 °C Housing design: With PMMA viewing window Housing material: 303 Repeatability: ≤ 2 mm IO-Link: + Upper signal level: 20 mA ... 20.5 mA Supply voltage: 12 V DC ... 30 V DC Process connection: G ¾ A