Specification: Part Number 1065347 Protection class: III Inductive load: < 1 H Connection type: Round connector M12 x 1, 5-pin Output current: < 100 mA Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Response time: < 400 ms IO-Link: + Accuracy of sensor element: ± 5 mm Measurement: Switch, Continuous Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Capacitive load: 100 nF Medium: Fluids Process connection: G ¾ A Max.probe load: 6 Nm GOST approval: + 3-A: - MTTF: 194.3 a (EN ISO 13849-1) Housing material: 303 Process temperature: -20 °C ... +150 °C Initialization time: ≤ 2 s Supply voltage: 12 V DC ... 30 V DC Upper signal level: 20 mA ... 20.5 mA Inactive area at probe end: 10 mm Lower signal level: 3.8 mA ... 4 mA Resolution: < 2 mm Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Hysteresis: Min. 2 mm, free adjustable Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Signal voltage LOW: ≤ 2 V EHEDG approval: + Power consumption: ≤ 75 mA at 24 V DC without output load Inactive area at process connector: 25 mm UL approval: + Probe length: 3,000 mm Interference emission: EN 61000-6-4:2007 Interference resistance: EN 61000-6-2:2005 Conductivity: No limitation Single- and continuous shock: EN 60068-2-27 Housing design: With PMMA viewing window Ambient storage temperature: -40 °C ... +80 °C Ambient temperature operation: -20 °C ... +60 °C Repeatability: ≤ 2 mm Temperature drift: < 0.1 mm/K Signal voltage HIGH: Vs - 2 V EMC: EN 61326-1:2006, 2004/108/EG Process pressure: -1 bar ... 16 bar RoHS certificate: +