Specification: Part Number 1071110 Initialization time: ≤ 5 s Enclosure rating: IP 67: EN 60529 Connection type: Round connector M12 x 1, 8-pin Process connection: ¾" NPT Inactive area at probe end: 10 mm Repeatability: ≤ 2 mm EMC: EN 61326-1:2006, 2004/108/EG Signal voltage LOW: ≤ 2 V Process pressure: -1 bar ... 10 bar Inactive area at process connector: 25 mm Ambient storage temperature: -40 °C ... +80 °C Wetted parts: 1.4404, PTFE CULus certificate: + Probe type: Mono rod probe Design: Remote amplifier, cable length 1 m Response time: < 400 ms Protection class: III Maximum level change: 500 mm/s Ambient temperature coaxial cable: -20 °C ... +60 °C Temperature drift: < 0.1 mm/K Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Max.probe load: 6 Nm RoHS certificate: + Output current: < 100 mA Hysteresis: Min. 2 mm, free adjustable Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Inductive load: < 1 H Conductivity: No limitation Capacitive load: 100 nF Process temperature: -20 °C ... +100 °C GOST approval: + Housing material: Plastic PBT Measurement: Switch, Continuous Length coaxial cable: 1 m, PVC Signal voltage HIGH: Vs - 2 V Lower signal level: 3.8 mA ... 4 mA MTTF: 194.3 a (EN ISO 13849-1) Upper signal level: 20 mA ... 20.5 mA Power consumption: ≤ 100 mA at 24 V DC without output load Ambient temperature operation: -20 °C ... +60 °C Supply voltage: 12 V DC ... 30 V DC IO-Link: + Resolution: < 2 mm Accuracy of sensor element: ± 5 mm Probe length: 2,000 mm Medium: Fluids