Specification: Part Number 1071090 Inductive load: < 1 H GOST approval: + Probe type: Mono rod probe Ambient temperature operation: -20 °C ... +60 °C Length coaxial cable: PVC Maximum level change: 500 mm/s Supply voltage: 12 V DC ... 30 V DC Ambient storage temperature: -40 °C ... +80 °C Repeatability: ≤ 2 mm Connection type: Round connector M12 x 1, 8-pin IO-Link: + Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Inactive area at probe end: 10 mm Output current: < 100 mA Accuracy of sensor element: ± 5 mm Process connection: G ¾ A Process pressure: -1 bar ... 10 bar Capacitive load: 100 nF Housing material: Plastic PBT Resolution: < 2 mm Probe length: 2,000 mm Temperature drift: < 0.1 mm/K Process temperature: -20 °C ... +100 °C Design: Remote amplifier, cable length 1 m Power consumption: ≤ 100 mA at 24 V DC without output load CULus certificate: + Lower signal level: 3.8 mA ... 4 mA Enclosure rating: IP 67: EN 60529 Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Upper signal level: 20 mA ... 20.5 mA MTTF: 194.3 a (EN ISO 13849-1) Protection class: III Medium: Fluids Measurement: Switch, Continuous Signal voltage HIGH: Vs - 2 V Initialization time: ≤ 5 s Inactive area at process connector: 25 mm Max.probe load: 6 Nm Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Conductivity: No limitation EMC: EN 61326-1:2006, 2004/108/EG Hysteresis: Min. 2 mm, free adjustable Response time: < 400 ms Ambient temperature coaxial cable: -20 °C ... +60 °C Signal voltage LOW: ≤ 2 V Wetted parts: 1.4404, PTFE RoHS certificate: +