Specification: Part Number 1071117 Signal voltage HIGH: Vs - 2 V Upper signal level: 20 mA ... 20.5 mA Conductivity: No limitation Housing material: Plastic PBT Inductive load: < 1 H Ambient temperature operation: -20 °C ... +60 °C Maximum level change: 500 mm/s Initialization time: ≤ 5 s CULus certificate: + Accuracy of sensor element: ± 5 mm Hysteresis: Min. 2 mm, free adjustable Inactive area at probe end: 10 mm Medium: Fluids Process connection: ¾" NPT Capacitive load: 100 nF Ambient storage temperature: -40 °C ... +80 °C Process temperature: -20 °C ... +100 °C Probe length: 1,000 mm Output current: < 100 mA MTTF: 194.3 a (EN ISO 13849-1) Protection class: III Power consumption: ≤ 100 mA at 24 V DC without output load Temperature drift: < 0.1 mm/K Response time: < 400 ms Length coaxial cable: 3.3 m, PVC Process pressure: -1 bar ... 10 bar Repeatability: ≤ 2 mm RoHS certificate: + IO-Link: + Enclosure rating: IP 67: EN 60529 Ambient temperature coaxial cable: -20 °C ... +60 °C Connection type: Round connector M12 x 1, 8-pin EMC: EN 61326-1:2006, 2004/108/EG Inactive area at process connector: 25 mm Max.probe load: 6 Nm Wetted parts: 1.4404, PTFE GOST approval: + Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Signal voltage LOW: ≤ 2 V Supply voltage: 12 V DC ... 30 V DC Resolution: < 2 mm Measurement: Switch, Continuous Lower signal level: 3.8 mA ... 4 mA Design: Remote amplifier, cable length 3 m Probe type: Mono rod probe Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe