Specification: Part Number 1062272 Medium: Fluids Protection class: III Initialization time: ≤ 5 s Temperature drift: < 0.1 mm/K Inactive area at probe end: 10 mm Conductivity: No limitation Maximum level change: 500 mm/s Process connection: ¾" NPT MTTF: 194.3 a (EN ISO 13849-1) Design: Standard Process temperature: -20 °C ... +100 °C Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Housing material: Plastic PBT Connection type: Round connector M12 x 1, 8-pin Ambient storage temperature: -40 °C ... +80 °C Power consumption: ≤ 100 mA at 24 V DC without output load Hysteresis: Min. 2 mm, free adjustable IO-Link: + Wetted parts: 1.4404, PTFE Lower signal level: 3.8 mA ... 4 mA Upper signal level: 20 mA ... 20.5 mA Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Inductive load: < 1 H RoHS certificate: + Signal voltage HIGH: Vs - 2 V Measurement: Switch, Continuous Accuracy of sensor element: ± 5 mm Inactive area at process connector: 25 mm Probe type: Mono rod probe Output current: < 100 mA Enclosure rating: IP 67: EN 60529 CULus certificate: + Probe length: 1,000 mm Ambient temperature operation: -20 °C ... +60 °C Max.probe load: 6 Nm Supply voltage: 12 V DC ... 30 V DC Signal voltage LOW: ≤ 2 V GOST approval: + Response time: < 400 ms EMC: EN 61326-1:2006, 2004/108/EG Resolution: < 2 mm Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Process pressure: -1 bar ... 10 bar Repeatability: ≤ 2 mm Capacitive load: 100 nF