Specification: Part Number 1071106 Inactive area at probe end: 10 mm GOST approval: + CULus certificate: + Maximum level change: 500 mm/s Supply voltage: 12 V DC ... 30 V DC IO-Link: + Inactive area at process connector: 25 mm Repeatability: ≤ 2 mm Process connection: ¾" NPT MTTF: 194.3 a (EN ISO 13849-1) Inductive load: < 1 H Wetted parts: 1.4404, PTFE Initialization time: ≤ 5 s Temperature drift: < 0.1 mm/K Design: Remote amplifier, cable length 3 m Protection class: III Power consumption: ≤ 100 mA at 24 V DC without output load Capacitive load: 100 nF Resolution: < 2 mm Enclosure rating: IP 67: EN 60529 Length coaxial cable: 3.3 m, PVC Measurement: Switch, Continuous Output current: < 100 mA Ambient temperature operation: -20 °C ... +60 °C Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Process pressure: -1 bar ... 10 bar Upper signal level: 20 mA ... 20.5 mA Connection type: Round connector M12 x 1, 5-pin Max.probe load: 6 Nm Response time: < 400 ms Signal voltage LOW: ≤ 2 V RoHS certificate: + Signal voltage HIGH: Vs - 2 V Lower signal level: 3.8 mA ... 4 mA Accuracy of sensor element: ± 5 mm Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Ambient temperature coaxial cable: -20 °C ... +60 °C Hysteresis: Min. 2 mm, free adjustable Probe type: Mono rod probe Conductivity: No limitation EMC: EN 61326-1:2006, 2004/108/EG Ambient storage temperature: -40 °C ... +80 °C Output signal: 1 PNP transistor output (Q1) and 1 PNP / NPN transistor output (Q2) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Process temperature: -20 °C ... +100 °C Housing material: Plastic PBT Medium: Fluids Probe length: 700 mm