Specification: Part Number 1052070 Repeatability: ≤ 2 mm Protection class: III Hysteresis: Min. 2 mm, free adjustable Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Upper signal level: 20 mA ... 20.5 mA Measurement: Switch, Continuous Inductive load: < 1 H Conductivity: No limitation Medium: Fluids Accuracy of sensor element: ± 5 mm Resolution: < 2 mm Output current: < 100 mA GOST approval: + Housing design: With PMMA viewing window Process pressure: -1 bar ... 16 bar Max.probe load: 6 Nm Temperature drift: < 0.1 mm/K IO-Link: + Lower signal level: 3.8 mA ... 4 mA Capacitive load: 100 nF Probe length: 500 mm UL approval: + Inactive area at probe end: 10 mm Initialization time: ≤ 2 s Ambient storage temperature: -40 °C ... +80 °C Process temperature: -20 °C ... +150 °C RoHS certificate: + Housing material: 303 EMC: EN 61326-1:2006, 2004/108/EG Process connection: G ¾ A Signal voltage HIGH: Vs - 2 V EHEDG approval: + Signal voltage LOW: ≤ 2 V Power consumption: ≤ 75 mA at 24 V DC without output load Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Supply voltage: 12 V DC ... 30 V DC Response time: < 400 ms Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Interference emission: EN 61000-6-4:2007 MTTF: 194.3 a (EN ISO 13849-1) Inactive area at process connector: 25 mm Interference resistance: EN 61000-6-2:2005 Connection type: Round connector M12 x 1, 5-pin Ambient temperature operation: -20 °C ... +60 °C Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Single- and continuous shock: EN 60068-2-27 3-A: -