LFP0500-G1BMB

Specification: Part Number 1071118 Protection class: III Interference resistance: EN 61000-6-2:2005 Inactive area at process connector: 25 mm Wetted parts: 316L (Ra &le; 0,8 µm), PEEK 3-A: - Repeatability: &le; 2 mm EHEDG approval: + Measurement: Switch, Continuous Power consumption: &le; 75 mA at 24 V DC without output load Lower signal level: 3.8 mA ... 4 mA GOST approval: + Housing material: 303 Max.probe load: 6 Nm Hysteresis: Min. 2 mm, free adjustable Supply voltage: 12 V DC ... 30 V DC MTTF: 194.3 a (EN ISO 13849-1) Connection type: Round connector M12 x 1, 5-pin Accuracy of sensor element: ± 5 mm Medium: Fluids Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Housing design: With PMMA viewing window UL approval: + Ambient temperature operation: -20 °C ... +60 °C Signal voltage HIGH: Vs - 2 V RoHS certificate: + Upper signal level: 20 mA ... 20.5 mA Response time: < 400 ms Length coaxial cable: 1 m, FEP Temperature drift: < 0.1 mm/K Process pressure: -1 bar ... 16 bar Interference emission: EN 61000-6-4:2007 Inactive area at probe end: 10 mm Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Single- and continuous shock: EN 60068-2-27 EMC: EN 61326-1:2006, 2004/108/EG IO-Link: + Signal voltage LOW: &le; 2 V Capacitive load: 100 nF Process connection: G ¾ A Output current: < 100 mA Dielectricity constant: &ge; 1.8 with coaxial tube, &ge; 5 for mono probe Resolution: < 2 mm Ambient temperature coaxial cable: -20 °C ... +60 °C Conductivity: No limitation Inductive load: < 1 H Process temperature: -20 °C ... +180 °C Ambient storage temperature: -40 °C ... +80 °C Initialization time: &le; 2 s
Part Number LFP0500-G1BMB
Manufacture SICK
  • 1+ million product
    50+ Manufacturers
  • Free Shipping
    For orders from $50
  • Support 24/7
    Call us anytime
  • 100% Safety
    Only secure payments
Menu
Mail Us
enquiry@onstocktrading.com