Specification: Part Number 1061713 Usage: Flaxi Loop master node to connect a Flexi Loop cascade to Flexi Classic. System diagnostics during operation and during commisioning without busmaster. IO-Link: -
Specification: Part Number 1067650 Usage: Flaxi Loop master node to connect a Flexi Loop cascade to Flexi Classic. System diagnostics during operation and during commisioning without busmaster. IO-Link: +
Specification: Part Number 1061715 IO-Link: - Usage: The power supply module is used to connect a power supply with 24 V DC, for the electrical isolation and for overcurrent shutdown.
Specification: Part Number 2074733 Usage: The Flexi Loop Y-adapter (EMMS) splits the 8-pin connection of the FLN-EMSS1100108 in two 5-pin connections: One for dual-channel equivalent electro-mechanical safety switches and one for non-safe I/O signals. IO-Link: -
Specification: Part Number 2074734 Usage: The Flexi Loop Y-adapter (OSSD) splits the 8-pin connection of the FLN-OSSD1100108 in two 5-pin connections: One for safety sensors with dual-channel OSSD outputs and one for non-safe I/O signals. IO-Link: -
Specification: Part Number 1061711 TM (mission time): 20 a (EN ISO 13849) Power supply output for external devices: - Performance level: PL e (EN ISO 13849-1) Connection type Flexi Loop output: Female connector M12, 5-pin Enclosure rating: IP 65, IP 67 (EN 60529) Safety device connection: Dual-channel equivalent electro-mechanical safety switch (EMSS) Type of supply voltage: SELV Shock resistance (single shock)
Specification: Part Number 1061712 Power consumption: 55 mA Type of supply voltage: SELV PFHd: 0.76 1E-09 (EN ISO 13849) Safety device connection: Dual-channel equivalent electro-mechanical safety switch (EMSS) Short-circuit: Monitoring via Flexi Loop node Electromagnetic compatibility (EMC): Class A (EN 61000-6-2, EN 55011) Discrepancy errors: Monitoring via Flexi Loop node Shock resistance (single shock): 3
Specification: Part Number 1061709 Power consumption: 45 mA Electromagnetic compatibility (EMC): Class A (EN 61000-6-2, EN 55011) Connection type safety device: Female connector M12, 5-pin Storage temperature: -25 °C ... +70 °C Flexi Loop output: To connect a Flexi Loop successor module, or to terminate a Flexi Loop string with the Flexi Loop termination element. Performance level: PL e (EN ISO 13849-1) IO-Link:
Specification: Part Number 1061710 Flexi Loop output: To connect a Flexi Loop successor module, or to terminate a Flexi Loop string with the Flexi Loop termination element. Enclosure rating: IP 65, IP 67 (EN 60529) Cross-circuit: Monitoring via OSSD device IO-Link: - Connection type safety device: Female connector M12, 8-pin Flexi Loop input: To connect a Flexi Loop predecessor module, or to connect a Flexi Loop strin
Specification: Part Number 1061716 Usage: The terminator is used to terminate the safe sensor cascade on the last Flexi Loop node. IO-Link: -
Specification: Part Number 1044076 Enclosure rating terminals: IP 20 (EN 60529) Fieldbus, industrial network: CANopen Internal power consumption: ≤ 1.6 W Climate conditions according to: EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity) Voltage supply: Via FLEXBUS+ Protection class housing: IP 40 (EN 60529) Weight: 150 g (± 10 %) Ambient operating temperature: -25 °C ... +55 °C Sto
Specification: Part Number 1044072 Fieldbus, industrial network: EtherNet/IP Protection class housing: IP 40 (EN 60529) Storage temperature: -25 °C ... +70 °C Integrated Ethernet switch: 3-port layer-2 managed switch with Auto-MDI-X for automatic detection of crossed Ethernet cable Ambient operating temperature: -25 °C ... +55 °C Internal power consumption: ≤ 2.4 W Connection type: 2 x female connector, RJ
Specification: Part Number 1051432 Type of fieldbus integration: Integrated device Weight: 150 g (± 10 %) Voltage supply: Via FLEXBUS+ Data transmission rate: ≥10 Mbit/s (10Base-T) ≥100 Mbit/s (100Base-TX) (autosensing) Protection class housing: IP 40 (EN 60529) Protection class: III (EN 61140) Climate conditions according to: EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity) Vibration
Specification: Part Number 1044073 Weight: 125 g (± 10 %) Storage temperature: -25 °C ... +70 °C Electromagnetic compatibility (EMC): Class A (EN 61000-6-2, EN 55011) Vibration resistance: 5 g, 10 Hz ... 500 Hz (EN 60068-2-6) Integrated Ethernet switch: 3-port layer-2 managed switch with Auto-MDI-X for automatic detection of crossed Ethernet cable Type of fieldbus integration: Integrated device Internal power co
Specification: Part Number 1044074 Weight: 125 g (± 10 %) Protection class: III (EN 61140) Electromagnetic compatibility (EMC): Class A (EN 61000-6-2, EN 55011) Fieldbus, industrial network: PROFINET Ambient operating temperature: -25 °C ... +55 °C Connection type: 2 x female connector, RJ-45 Enclosure rating terminals: IP 20 (EN 60529) Protection class housing: IP 40 (EN 60529) Data transmission rate:
Specification: Part Number 1044075 Protection class: III (EN 61140) Climate conditions according to: EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity) Protection class housing: IP 40 (EN 60529) Ambient operating temperature: -25 °C ... +55 °C Voltage supply: Via FLEXBUS+ Data transmission rate: ≤ 12 MBaud ≤12,000 kbit/s Enclosure rating terminals: IP 20 (EN 60529) Connection type: 1
Specification: Part Number 1061778 Internal power consumption: ≤ 1.5 W Storage temperature: -25 °C ... +70 °C Air humidity: 10 % ... 95 %, non-condensing Electromagnetic compatibility (EMC): Class A (EN 61000-6-2, EN 55011) Dimensions (W x H x D): 22.5 mm x 96.5 mm x 120.6 mm Number of test signal outputs: 0 Ambient operating temperature: -25 °C ... +55 °C Number of non-safe inputs: 6-8 (I1 - I6, IY7,
Specification: Part Number 1043783 Number of EFI interfaces: 0 Configuration and diagnostics interface: RS-232 Connection type system plug: Screw-type terminals Climate conditions according to: EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity) System connection: System plug FX3-MPL000001 Flexi Link: - Weight: 111 g (± 5 %) Flexi Line: - Safety integrity level: SIL3 (IEC 61508) SILCL3 (E
Specification: Part Number 1043784 Overvoltage category: II (EN 61131-2) Safe SICK device communication via EFI/SDL: + TM (mission time): 20 a (EN ISO 13849) Automatic Configuration Recovery (ACR): - Connection type system plug: Screw-type terminals Supply voltage Vs: 24 V DC (16.8 V DC ... 30 V DC) Switch-on time: ≤ 18 s Type of voltage supply: PELV or SELV Restart interlock: Manual / automatic (confi
Specification: Part Number 1058999 PFHd: 1.69 1E-09 (EN ISO 13849) Type of voltage supply: PELV or SELV Configuration and diagnostics interface: RS-232 Connection type system plug: Screw-type terminals Storage temperature: -25 °C ... +70 °C Differentiation between man and material (muting): + Weight: 119 g (± 5 %) Protection class housing: IP 40 (EN 60529) Protection class: III (EN 61140) Automatic
Specification: Part Number 1059305 Protection class housing: IP 40 (EN 60529) Flexi Line: + Connection type EFI connection: Spring terminals Internal power consumption: ≤ 2.5 W TM (mission time): 20 a (EN ISO 13849) Configuration and diagnostics interface: RS-232, USB Switch-on time: ≤ 18 s Storage temperature: -25 °C ... +70 °C Supply voltage Vs: 24 V DC (16.8 V DC ... 30 V DC) Climate conditio
Specification: Part Number 1062344 Safe brake control (SBC): + Data interface: Internal bus (FLEXBUS+) Protection class: III (EN 61140) Safe operating stop (SOS): + Storage temperature: -25 °C ... +70 °C Safe stop 1 (SS1): + TM (mission time): 20 a (EN ISO 13849) Safe state in the event of a fault: The safety-related data is logic 0. Connection type: Male connector, Micro D-Sub, 15-pin Safe limited sp
Specification: Part Number 1044124 Dimensions (W x H x D): 22.5 mm x 96.5 mm x 120.6 mm Number of safe outputs: 0 Electromagnetic compatibility (EMC): Class A (EN 61000-6-2, EN 55011) Flexi Loop-compatible: + Weight: 139 g (± 5 %) Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Fast shut-off: - PFHd: 0.4 1E-09 (EN ISO 13849) Number of non-safe outputs: 0 Vibration resistance: 1 g, 5 Hz ...
Specification: Part Number 1061777 Connection type: Spring terminals Number of test signal outputs: 2 (XY1, XY2) Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Enclosure rating terminals: IP 20 (EN 60529) Internal power consumption: ≤ 1.5 W Voltage supply test signal outputs: Via FLEXBUS+ Protection class housing: IP 40 (EN 60529) Number of safe outputs: 0 Ambient operating temperature: -25
Specification: Part Number 1044125 Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Ambient operating temperature: -25 °C ... +55 °C Number of non-safe inputs: 0 Climate conditions according to: EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity) PFHd: 0.9 1E-09 (EN ISO 13849) 4.8 1E-09 (EN ISO 13849) Air humidity: 10 % ... 95 %, non-condensing Protection class housing: IP 40 (EN 6
Specification: Part Number 6034245 Ripple: ≤ 10 % Selectable speed limit: 0.1 Hz ... 9.9 Hz Number of safety inputs: 4 (I1 - I4) Safe speed monitoring (SSM): + Performance level: PL e (EN ISO 13849-1) Number of application diagnostic outputs: 2 (X1, X2) Enclosure rating terminals: IP 20 (EN 60529) TM (mission time): 20 a (EN ISO 13849) Number of safe outputs: 4 (Q1 - Q4) Air humidity: 10 % ... 95 %
Specification: Part Number 6034246 Stop category: 0 (EN 60204) Type of output application diagnostic output: PNP semiconductor, short-circuit protected Number of safety inputs: 4 (I1 - I4) Selectable speed limit: 0.1 Hz ... 9.9 Hz Performance level: PL e (EN ISO 13849-1) Protection class: III (EN 61140) Dimensions (W x H x D): 22.5 mm x 106.5 mm x 121 mm Type of parameterization: Screwdriver Number of appli
Specification: Part Number 6034247 Safe limited speed (SLS): + Number of safety inputs: 4 (I1 - I4) Connection type: Screw-type terminals Number of safe outputs: 4 (Q1 - Q4) Output voltage: 18.4 V DC ... 30 V DC Power consumption: ≤ 3 W Performance level: PL e (EN ISO 13849-1) Ambient operating temperature: -25 °C ... +55 °C Climate conditions according to: EN 61131-2 Type of parameterization: Scr
Specification: Part Number 6034248 Number of application diagnostic outputs: 2 (X1, X2) Connection type: Spring terminals Selectable speed limit: 0.5 Hz ... 99 Hz Ambient operating temperature: -25 °C ... +55 °C Safe speed monitoring (SSM): + Protection class: III (EN 61140) Safe limited speed (SLS): + Air humidity: 10 % ... 95 %, non-condensing Ripple: ≤ 10 % Number of safe outputs: 4 (Q1 - Q4)
Specification: Part Number 6044982 PFHd: 41 1E-09 (EN ISO 13849) Contact configuration (safety contacts): 3 contacts NO, 1 contact NC Maximum switching frequency: 1,200 /h Voltage threshold Uan: 20 mV ... 400 mV, adjustable Measurement inputs: L1/L2/L3 Response time: 100 ms Stop category: 1 (EN 60204-1) Mounting: 35 mm mounting rail according to EN 60715 Dimensions (W x H x D): 45 mm x 112 mm x 121 mm