Specification: Part Number 1036376 Maximum operating speed: 6,000 U/min Error limits binary number of lines: 0.09 ° Reference signal, number: 1 Bearing lifetime: 2 x 10^9 revolutions Operating torque: 0.4 Ncm (+20 °C) Shaft diameter: 8 mm x 13 mm Output current: 30 mA Start up torque: 0.6 Ncm (+20 °C) Connection type: Cable, universal, 0.5 m Measuring step deviation at binary number of lines: 0.035
Specification: Part Number 1037860 Permissible shaft loading radial/axial: 40 N, 20 N Error limits non-binary number of lines: 0.13 ° Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Air humidity: 90 % Reference signal, position: 90 °, electronically, gated with A and B Measuring step deviation at binary number of lines: 0.035 ° Storage temperature range: -40 °C ... +70 °C, without package
Specification: Part Number 1053470 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Operating torque: 0.4 Ncm (+20 °C) Measuring step deviation at non binary number of lines: 0.07 ° Mechanical interface: Solid shaft, Face mount flange Maximum output frequency: 50 kHz MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Working temperature range: 0 °C ... +60 °C Shaft diameter: 8 mm x 13 mm Sto
Specification: Part Number 1055770 Operating torque: 0.4 Ncm (+20 °C) Output current: 30 mA Electrical interface: 4.5 V ... 5.5 V, Open Collector NPN, Cable with plug M12, 8-pin, cable with connector, universal, 1.5 m Permissible shaft loading radial/axial: 40 N, 20 N Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Working temperature range: 0 °C ... +60 °C Mechanical interface: Solid shaft, Face mount flange
Specification: Part Number 1035691 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Measuring step deviation at non binary number of lines: 0.07 ° Electrical interface: 10 V ... 30 V, Open Collector NPN, Cable, universal, 0.5 m Protection class housing side with cable outlet: IP 64 Error limits binary number of lines: 0.09 ° Protection class standard: IEC 60529 Initialization time: 40 s Max. a
Specification: Part Number 1036294 EMC: EN 61000-6-2, EN 61000-6-3 Error limits non-binary number of lines: 0.13 ° Start up torque: 0.6 Ncm (+20 °C) Working temperature range: 0 °C ... +60 °C Mechanical interface: Solid shaft, Face mount flange Pulses per revolution: 2 Operating power consumption (no load): 40 mA Protection class housing side with cable outlet: IP 64 Bearing lifetime: 2 x 10^9 revolut
Specification: Part Number 1036698 Shaft diameter: 8 mm x 13 mm Output current: 30 mA Bearing lifetime: 2 x 10^9 revolutions Measuring step deviation at non binary number of lines: 0.07 ° MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Pulses per revolution: 12 Measuring step: 90 °, Number of lines Initialization time: 40 s Reference signal, position: 90 °, electronically, gated with A a
Specification: Part Number 1035300 Maximum output frequency: 50 kHz Initialization time: 40 s Shaft diameter: 8 mm x 13 mm Error limits binary number of lines: 0.09 ° Protection class standard: IEC 60529 Supply voltage: 10 V ... 30 V Mechanical interface: Solid shaft, Face mount flange Output current: 30 mA Electrical interface: 10 V ... 30 V, Open Collector NPN, Cable, universal, 0.5 m Max. angular ac
Specification: Part Number 1036154 Initialization time: 40 s Error limits non-binary number of lines: 0.13 ° Electrical interface: 10 V ... 30 V, Open Collector NPN, Cable, universal, 0.5 m Output current: 30 mA Maximum operating speed: 6,000 U/min Connection type: Cable, universal, 0.5 m EMC: EN 61000-6-2, EN 61000-6-3 Storage temperature range: -40 °C ... +70 °C, without package Working temperature ran
Specification: Part Number 1036155 Initialization time: 40 s Permissible shaft loading radial/axial: 40 N, 20 N Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Error limits binary number of lines: 0.09 ° Error limits non-binary number of lines: 0.13 ° Operating torque: 0.4 Ncm (+20 °C) Protection class standard: IEC 60529 Measuring step: 90 °, Number of lines Moment of inertia of the rotor: 6 gcm²
Specification: Part Number 1036684 Error limits non-binary number of lines: 0.13 ° Operating power consumption (no load): 40 mA Protection class housing side with cable outlet: IP 64 Initialization time: 40 s MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Start up torque: 0.6 Ncm (+20 °C) Mechanical interface: Solid shaft, Face mount flange Measuring step: 90 °, Number of lines Protection
Specification: Part Number 1035772 Error limits binary number of lines: 0.09 ° Measuring step deviation at non binary number of lines: 0.07 ° Air humidity: 90 % Electrical interface: 10 V ... 30 V, Open Collector NPN, Cable, universal, 3 m Mass: 0.18 kg Working temperature range: 0 °C ... +60 °C Permissible shaft loading radial/axial: 40 N, 20 N EMC: EN 61000-6-2, EN 61000-6-3 Supply voltage: 10 V ...
Specification: Part Number 1035619 Permissible shaft loading radial/axial: 40 N, 20 N Initialization time: 40 s Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Measuring step: 90 °, Number of lines Error limits binary number of lines: 0.09 ° Air humidity: 90 % Protection class standard: IEC 60529 Working temperature range: 0 °C ... +60 °C EMC: EN 61000-6-2, EN 61000-6-3 Shaft diameter: 8 mm x 13
Specification: Part Number 1036323 Supply voltage: 10 V ... 30 V Protection class housing side with cable outlet: IP 64 Moment of inertia of the rotor: 6 gcm² Air humidity: 90 % Reference signal, position: 90 °, electronically, gated with A and B Protection class standard: IEC 60529 Mass: 0.18 kg Measuring step: 90 °, Number of lines Error limits non-binary number of lines: 0.13 ° Max. angular acce
Specification: Part Number 1036229 Maximum output frequency: 50 kHz Initialization time: 40 s Electrical interface: 10 V ... 30 V, Open Collector NPN, Cable, universal, 5 m Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Shaft diameter: 8 mm x 13 mm Reference signal, number: 1 Start up torque: 0.6 Ncm (+20 °C) Reference signal, position: 90 °, electronically, gated with A and B Measuring
Specification: Part Number 1036685 Protection class shaft side: IP 64 Mass: 0.18 kg Protection class housing side with cable outlet: IP 64 Connection type: Cable, universal, 5 m Protection class standard: IEC 60529 Measuring step deviation at non binary number of lines: 0.07 ° Max. angular acceleration: 3,6 x 10^9 rad/s² Initialization time: 40 s MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849
Specification: Part Number 1061105 Measuring step deviation at binary number of lines: 0.035 ° Reference signal, position: 90 °, electronically, gated with A and B MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Working temperature range: 0 °C ... +60 °C Moment of inertia of the rotor: 6 gcm² Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Pulses per revolution: 500 Connection type: Cable
Specification: Part Number 1035040 Mechanical interface: Measuring drum, knurled surface Storage temperature range: -40 °C ... +70 °C, without package Enclosure rating: IP 65 Connection type: Cable, 1.5 m EMC: EN 61000-6-2, EN 61000-6-3 MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Smallest measuring step: 0.25 mm Reference signal, number: 1 Maximum operating speed: 1,500 U/min Output
Specification: Part Number 1035041 Air humidity: 90 % Supply voltage: 4.5 V ... 5.5 V Connection type: Cable, 1.5 m Smallest measuring step: 0.05 mm Mass: 0.42 kg Working temperature range: -10 °C ... +60 °C Output current: 30 Storage temperature range: -40 °C ... +70 °C, without package Resolution: 0.2 mm Bearing lifetime: 2 x 10^9 revolutions Reference signal, position: 90 °, electronicall
Specification: Part Number 1035042 Pulses per revolution: 2,000 Air humidity: 90 % Initialization time: 40 s Smallest measuring step: 0.025 mm Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, 1.5 m Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Enclosure rating: IP 65 Resolution: 0.1 mm MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Reference signal, position:
Specification: Part Number 1035745 Reference signal, position: 90 °, electronically, gated with A and B MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Connection type: Cable, M12, 8-pin, 1.5 m Initialization time: 40 s Enclosure rating: IP 65 Error limits knurled surface: ± 0.5 mm Resolution: 1 mm Working temperature range: -10 °C ... +60 °C Maximum operating speed: 1,500 U/min Air h
Specification: Part Number 1037527 Error limits knurled surface: ± 0.5 mm Mass: 0.42 kg Air humidity: 90 % Reference signal, position: 90 °, electronically, gated with A and B Pulses per revolution: 2,000 Connection type: Cable, M12, 8-pin, 1.5 m Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, M12, 8-pin, 1.5 m Smallest measuring step: 0.025 mm EMC: EN 61000-6-2, EN 61000-6-3 Reference sign
Specification: Part Number 1035043 Protection class standard: IEC 60529 MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Reference signal, position: 90 °, electronically, gated with A and B Resolution: 10 mm Smallest measuring step: 2.5 mm Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) EMC: EN 61000-6-2, EN 61000-6-3 Enclosure rating: IP 65 Pulses per revolution: 20 Res
Specification: Part Number 1036267 EMC: EN 61000-6-2, EN 61000-6-3 Supply voltage: 4.5 V ... 5.5 V Bearing lifetime: 2 x 10^9 revolutions Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, 1.5 m Protection class standard: IEC 60529 Connection type: Cable, 1.5 m Error limits 'O' ring surface: ± 4 mm Storage temperature range: -40 °C ... +70 °C, without package Mass: 0.42 kg Smallest measuring
Specification: Part Number 1035044 Maximum operating speed: 1,500 U/min Resolution: 1 mm Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) EMC: EN 61000-6-2, EN 61000-6-3 Reference signal, position: 90 °, electronically, gated with A and B Error limits 'O' ring surface: ± 4 mm Mass: 0.42 kg Pulses per revolution: 200 Initialization time: 40 s Smallest measuring step: 0.25 mm Storage temperature
Specification: Part Number 1036587 Mass: 0.42 kg Supply voltage: 4.5 V ... 5.5 V Initialization time: 40 s Reference signal, number: 1 Smallest measuring step: 0.025 mm Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, M12, 8-pin, 1.5 m Connection type: Cable, M12, 8-pin, 1.5 m Maximum operating speed: 1,500 U/min Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Storage temperature range: -40 °
Specification: Part Number 1035767 Mechanical interface: Measuring drum, knurled surface Air humidity: 90 % Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, 1.5 m Supply voltage: 10 V ... 30 V Mass: 0.42 kg Pulses per revolution: 3 Reference signal, position: 90 °, electronically, gated with A and B Working temperature range: -10
Specification: Part Number 1036157 Protection class standard: IEC 60529 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Error limits knurled surface: ± 0.5 mm Smallest measuring step: 12.5 mm Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, 1.5 m Pulses per revolution: 4 Resolution: 50 mm MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Storage temperature range: -40 °C ... +70
Specification: Part Number 1036156 Bearing lifetime: 2 x 10^9 revolutions Supply voltage: 10 V ... 30 V Protection class standard: IEC 60529 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Resolution: 13.34 mm Reference signal, position: 90 °, electronically, gated with A and B Reference signal, number: 1 Pulses per revolution: 15 Enclosure rating: IP 65 Maximum operating speed: 1,500 U/min Init
Specification: Part Number 1035571 Reference signal, position: 90 °, electronically, gated with A and B Resolution: 5 mm Working temperature range: -10 °C ... +60 °C Bearing lifetime: 2 x 10^9 revolutions Storage temperature range: -40 °C ... +70 °C, without package Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) EMC: EN 61000-6-2, EN 61000-