Specification: Part Number 1068240 Remark (Ethernet): Optional via external connection module (CDF600-2) Version: Long Range Protocol (Ethernet): PROFINET Dual Port Operating voltage: 10 V DC ... 30 V DC No. of characters per reading interval: 1,500, 500 (for multiplexer function in CAN operation) Protection class: III (VDE 0106/IEC 1010-1) Vibration resistance: EN 60068-2-6 (2008-02) Serial (RS-232): + Sca
Specification: Part Number 1066374 No. of codes per scan: 1 ... 20 (Standard decoder), 1 ... 6 (SMART620) Enclosure rating: IP 69K (DIN 40 050, part 9) Reading distance: 63 mm ... 347 mm Configuration software: SOPAS ET Ambient light safety: 2,000 lx, on bar code Reading pulse: Auto pulse, CAN, Switching inputs, Serial interface Data transmission rate (Serial (RS-232, RS-422/485)): 2,400 Baud ... 115 Baud, AUX: 5
Specification: Part Number 1067571 Operating voltage: 10 V DC ... 30 V DC No. of codes per scan: 1 ... 20 (Standard decoder), 1 ... 6 (SMART620) Permissible relative humidity: 90 %, non-condensing Serial (RS-232, RS-422/485): + Data transmission rate (Serial (RS-232, RS-422/485)): 2,400 Baud ... 115 kBaud, AUX: 57.6 kBaud Version: Long Range Light source: Visible red light (655 nm) Acoustic indicators: Beeper/
Specification: Part Number 1062136 Function (Ethernet): Host, AUX Weight: 1,230 g, without connecting cable Data transmission rate (Ethernet): 10/100 Mbit Shock resistance: EN 60068-2-27 (1993) Function (Serial (RS-232, RS-422/485)): Host, AUX Configuration software: SOPAS ET Scanner design: Line scanner Ethernet: + No. of characters per reading interval: 5,000, 500 (for multiplexer function in CAN operati
Specification: Part Number 1064718 Protection class: III (EN 61140) DeviceNet: + Ambient light safety: 2,000 lx, on bar code Housing: Stainless steel Reading distance: 47 mm ... 798 mm Light source: Visible red light (655 nm) Weight: 1,230 g, without connecting cable Version: Standard Density Reading pulse: Auto pulse, CAN, Switching inputs, Serial interface Data transmission rate (Ethernet): 10/100 M
Specification: Part Number 1042019 Connection type: Ethernet Weight: 270 g, without connecting cable Scanning frequency: 400 Hz ... 1,200 Hz Enclosure rating: IP 65 (EN 60529) Reading pulse: Auto pulse, CAN, Non-powered, "Sensor 1" switching input, Serial interface CAN bus: + Reading field: Side (105 °) Function (Serial (RS-232, RS-422/485)): Host, AUX Memory card: MicroSD memory card (flash card) 512 MB,
Specification: Part Number 1042020 Protection class: III (EN 61140) Remark (PROFIBUS DP): Optional via external connection module (CDF600-2) Function (Serial (RS-232, RS-422/485)): Host, AUX Enclosure rating: IP 65 (EN 60529) Laser class: 2 (EN 60825-1 (A2:2001-03)) DeviceNet: + Configuration software: SOPAS ET Power consumption: 5.5 W Remark (DeviceNet): Optional via external connection module (CDM + CMF)
Specification: Part Number 1042021 Ambient operating temperature: 0 °C ... +40 °C Switching outputs: 2 (via CMC600 in CDB620/CDM420) No. of characters per reading interval: 5,000, 500 (for multiplexer function in CAN operation) Focus: Dynamic focus control Data transmission rate (Ethernet): 10/100 Mbit Raster height, number of lines, at distance: 15 mm, 8, 185 mm Remark (Serial (RS-232, RS-422/485)): AUX (only R
Specification: Part Number 1042896 Protection class: III (EN 61140) Scanning frequency: 25 Hz, at 1.3 megapixels resolution Ambient light safety: 2,000 lx, on bar code Remark (PROFIBUS DP): Optional via external connection module (CDM + CMF) Reading pulse: Non-powered, Switching inputs, Serial interface Dimensions: 112 mm x 80 mm x 39 mm Enclosure rating: IP 30, IP 65 (EN 60529) Electromagnetic compatibility
Specification: Part Number 1042897 Sensor: CMOS matrix sensor Function (Ethernet): Host, AUX, image transmission Dimensions: 112 mm x 80 mm x 39 mm Data transmission rate (CAN bus): 10 kbit/s ... 1 Mbit/s Enclosure rating: IP 30, IP 65 (EN 60529) Permissible relative humidity: ± 90 %, non-condensing DeviceNet: + Laser class: 1 (EN 60825-1) Ethernet: + Weight: 900 g, with connecting cable Reading
Specification: Part Number 1042277 Data transmission rate (Ethernet): 10/100 Mbit Ethernet: + MTBF: 75,000 h Protocol (Ethernet): TCP/IP, FTP (image transmission), PROFINET (optional via external connection module CDM) Data transmission rate (Serial (RS-232)): 300 Baud ... 57,600 Baud, AUX: 9,600 Baud Scanning frequency: 25 Hz, at 1.3 megapixels resolution No. of characters per reading interval: 4,000 2D code t
Specification: Part Number 1042338 Ambient light safety: 2,000 lx, on bar code Switching outputs: 2 (Result 1 NPN, Result 2 PNP) 2D code types: Data Matrix ECC200, GS1 Data-Matrix, QR code Dimensions: 112 mm x 80 mm x 39 mm Sensor resolution: 1,280 px x 1,024 px (1.3 Mpixel Data transmission rate (Serial (RS-232)): 300 Baud ... 57,600 Baud, AUX: 9,600 Baud Function (CAN bus): SICK CAN sensor network (Master/Slave,
Specification: Part Number 1042279 Dimensions: 112 mm x 80 mm x 39 mm Housing: Die-cast zinc Focus: Fixed focus Focus position: 115 mm Power consumption: 13 W Enclosure rating: IP 30, IP 65 (EN 60529) Vibration resistance: EN 60068-2-6 Light source: Visible red light (lighting LEDs, 617 nm, ± 15 nm) Protocol (Ethernet): TCP/IP, FTP (image transmission), PROFINET (optional via external connection module
Specification: Part Number 1042885 Remark (DeviceNet): Optional via external connection module (CDM + CMF) Data transmission rate (CAN bus): 10 kbit/s ... 1 Mbit/s Remark (PROFIBUS DP): Optional via external connection module (CDM + CMF) Shock resistance: EN 60068-2-27 Permissible relative humidity: ± 90 %, non-condensing Electromagnetic compatibility (EMC): EN 61000-6-2 / EN 61000-6-4 Switching outputs: 2 (Resul
Specification: Part Number 1043547 Laser class: 1 (EN 60825-1) Optical indicators: 6 LEDs (status displays) Light source: Visible red light (lighting LEDs, 617 nm, ± 15 nm) Weight: 900 g, with connecting cable MTBF: 75,000 h Version: Long Range Electromagnetic compatibility (EMC): EN 61000-6-2 / EN 61000-6-4 Ambient light safety: 2,000 lx, on bar code Function (Ethernet): Host, AUX, image transmission
Specification: Part Number 1044617 Optical indicators: 6 LEDs (status displays) Permissible relative humidity: ± 90 %, non-condensing Protection class: III (EN 61140) Function (Serial (RS-232)): Host, AUX Housing color: Light blue (RAL 5012) Remark (PROFIBUS DP): Optional via external connection module (CDM + CMF) Function (CAN bus): SICK CAN sensor network (Master/Slave, Multiplexer) 2D code types: Data Matr
Specification: Part Number 1044616 Acoustic indicators: Beeper/buzzer (can be switched off, can be assigned a function to signal a result) Operating voltage: 15 V DC ... 30 V DC Reading distance: 30 mm ... 78 mm Data transmission rate (Serial (RS-232)): 300 Baud ... 57,600 Baud, AUX: 9,600 Baud Data transmission rate (CAN bus): 10 kbit/s ... 1 Mbit/s Reading pulse: Non-powered, Switching inputs, Serial interface
Specification: Part Number 1043740 Bar code types: Interleaved 2 of 5, Codabar, Code 128, Code 39, GS1-128 / EAN 128, Pharmacode, UPC / GTIN / EAN Switching outputs: 2 (Result 1 NPN, Result 2 PNP) Remark (DeviceNet): Optional via external connection module (CDM + CMF) DeviceNet: + Serial (RS-232): + Weight: 900 g, with connecting cable Function (CAN bus): SICK CAN sensor network (Master/Slave, Multiplexer) Ope
Specification: Part Number 1043739 Protection class: III (EN 61140) 2D code types: Data Matrix ECC200, GS1 Data-Matrix, QR code Protocol (Ethernet): TCP/IP, FTP (image transmission), PROFINET (optional via external connection module CDM) Data transmission rate (Serial (RS-232)): 300 Baud ... 57,600 Baud, AUX: 9,600 Baud Version: Mid Range MTBF: 75,000 h Reading field: Side Ambient light safety: 2,000 lx, on ba
Specification: Part Number 1047749 Weight: 900 g, with connecting cable Function (CAN bus): SICK CAN sensor network (Master/Slave, Multiplexer) Function (Ethernet): Host, AUX, image transmission Enclosure rating: IP 30, IP 65 (EN 60529) Housing: Die-cast zinc No. of characters per reading interval: 4,000 Data transmission rate (Ethernet): 10/100 Mbit Electrical connection: 1 x RJ45 female connector on device
Specification: Part Number 1047750 Housing: Die-cast zinc Bar code types: Interleaved 2 of 5, Codabar, Code 128, Code 39, GS1-128 / EAN 128, Pharmacode, UPC / GTIN / EAN Remark (DeviceNet): Optional via external connection module (CDM + CMF) Remark (PROFIBUS DP): Optional via external connection module (CDM + CMF) Version: Extended Long Range Reading field: Side No. of characters per reading interval: 4,000 Di
Specification: Part Number 1051094 Dimensions: 112 mm x 80 mm x 39 mm Housing color: Light blue (RAL 5012) Reading distance: 100 mm ... 230 mm No. of characters per reading interval: 4,000 Sensor: CMOS matrix sensor Light source: Visible red light (lighting LEDs, 617 nm, ± 15 nm) Bar code types: Interleaved 2 of 5, Codabar, Code 128, Code 39, GS1-128 / EAN 128, Pharmacode, UPC / GTIN / EAN Focus position:
Specification: Part Number 1056545 DeviceNet: + Focus position: 175 mm Ambient light safety: 2,000 lx Reading pulse: Non-powered, Switching inputs, Serial interface Remark (PROFIBUS DP): Optional via external connection module (CDM + CMF) Laser class: 1 (EN 60825-1) Sensor: CMOS matrix sensor Function (CAN bus): SICK CAN sensor network (Master/Slave, Multiplexer) Enclosure rating: IP 65 (EN 60529) IP 30
Specification: Part Number 6053054 DeviceNet: + Remark (DeviceNet): Optional via external connection module (CDM + CMF) Configuration software: IDM Setup Tool Scanner design: 2D code hand-held scanner Enclosure rating: IP 65 Vibration: Yes Function (USB): Keyboard wedge, COM-Port emulation Function (Bluetooth): Wireless operating range up to 100 m (free view), batch function for expansion of the wireless radiu