Specification: Part Number 1034634 Mechanical interface: Solid shaft, Face mount flange Error limits binary number of lines: 0.09 ° Measuring step deviation at binary number of lines: 0.035 ° Operating power consumption (no load): 40 mA Maximum output frequency: 200 kHz Moment of inertia of the rotor: 6 gcm² MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Resistance to shocks: 50 g, 7 ms (EN
Specification: Part Number 1034635 Output current: 30 mA Measuring step deviation at non binary number of lines: 0.07 ° Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Maximum output frequency: 200 kHz EMC: EN 61000-6-2, EN 61000-6-3 Reference signal, position: 90 °, electronically, gated with A and B Air humidity: 90 % Operating power consumption (no load): 40 mA MTTFd: mean time to dan
Specification: Part Number 1034636 Permissible shaft loading radial/axial: 40 N, 20 N Shaft diameter: 8 mm x 13 mm Supply voltage: 4.5 V ... 5.5 V Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Mass: 0.18 kg Measuring step deviation at binary number of lines: 0.035 ° Error limits binary number of lines: 0.09 ° Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, universal, 0.5 m Bearing lifetime: 2
Specification: Part Number 1034637 Mass: 0.18 kg Shaft diameter: 8 mm x 13 mm Operating torque: 0.4 Ncm (+20 °C) Reference signal, number: 1 Permissible shaft loading radial/axial: 40 N, 20 N Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Protection class shaft side: IP 64 Initialization time: 40 s Output current: 30 mA Maximum output frequency: 200 kHz Error limits binary number of lines: 0.09
Specification: Part Number 1034639 Reference signal, position: 90 °, electronically, gated with A and B Output current: 30 mA Start up torque: 0.6 Ncm (+20 °C) Maximum operating speed: 6,000 U/min Measuring step: 90 °, Number of lines Error limits binary number of lines: 0.09 ° Connection type: Cable, universal, 0.5 m Measuring step deviation at non binary number of lines: 0.07 ° Protection class stand
Specification: Part Number 1034640 Operating torque: 0.4 Ncm (+20 °C) Shaft diameter: 8 mm x 13 mm Protection class standard: IEC 60529 Connection type: Cable, universal, 0.5 m Reference signal, position: 90 °, electronically, gated with A and B Error limits binary number of lines: 0.09 ° Measuring step: 90 °, Number of lines Maximum output frequency: 200 kHz Mechanical interface: Solid shaft, Face mou
Specification: Part Number 1034641 Mechanical interface: Solid shaft, Face mount flange Mass: 0.18 kg EMC: EN 61000-6-2, EN 61000-6-3 Error limits binary number of lines: 0.09 ° Moment of inertia of the rotor: 6 gcm² Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, universal, 0.5 m Permissible shaft loading radial/axial: 40 N, 20 N Start up torque: 0.6 Ncm (+20 °C) Operating torque: 0.4 Ncm (+20
Specification: Part Number 1034642 Mass: 0.18 kg Operating torque: 0.4 Ncm (+20 °C) Maximum output frequency: 200 kHz Permissible shaft loading radial/axial: 40 N, 20 N MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Measuring step deviation at binary number of lines: 0.035 ° Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Maximum operating speed: 6,000 U/min Protection class housing side
Specification: Part Number 1034643 Protection class housing side with cable outlet: IP 64 Maximum operating speed: 6,000 U/min Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Air humidity: 90 % Start up torque: 0.6 Ncm (+20 °C) Pulses per revolution: 512 Maximum output frequency: 200 kHz Measuring step deviation at binary number of lines: 0.035 ° Resistance to shocks: 50 g, 7 ms (EN 600
Specification: Part Number 1034644 Pulses per revolution: 720 Maximum operating speed: 6,000 U/min Output current: 30 mA Connection type: Cable, universal, 0.5 m Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, universal, 0.5 m Error limits binary number of lines: 0.09 ° Operating power consumption (no load): 40 mA Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Protection class standard: IEC 605
Specification: Part Number 1034645 Max. angular acceleration: 3,6 x 10^9 rad/s² Bearing lifetime: 2 x 10^9 revolutions Operating power consumption (no load): 40 mA Start up torque: 0.6 Ncm (+20 °C) Error limits non-binary number of lines: 0.13 ° Mass: 0.18 kg Protection class housing side with cable outlet: IP 64 Initialization time: 40 s Protection class shaft side: IP 64 Resistance to vibration:
Specification: Part Number 1034646 Reference signal, number: 1 Error limits non-binary number of lines: 0.13 ° Moment of inertia of the rotor: 6 gcm² Max. angular acceleration: 3,6 x 10^9 rad/s² Protection class standard: IEC 60529 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Measuring step deviation at non binary number of lines: 0.07 ° Electrical interface: 4.5 V ... 5.5 V, TTL/RS422,
Specification: Part Number 1034815 Error limits non-binary number of lines: 0.13 ° Operating torque: 0.4 Ncm (+20 °C) Reference signal, number: 1 Error limits binary number of lines: 0.09 ° Operating power consumption (no load): 40 mA Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Bearing lifetime: 2 x 10^9 revolutions Working temperature range: 0 °C ... +60 °C Measuring step: 90 °
Specification: Part Number 1034816 Reference signal, number: 1 Measuring step: 90 °, Number of lines MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Mechanical interface: Solid shaft, Face mount flange Working temperature range: 0 °C ... +60 °C Shaft diameter: 8 mm x 13 mm Start up torque: 0.6 Ncm (+20 °C) Air humidity: 90 % Error limits non-binary number of lines: 0.13 ° Initializa
Specification: Part Number 1036073 Error limits non-binary number of lines: 0.13 ° Reference signal, number: 1 Operating torque: 0.4 Ncm (+20 °C) Reference signal, position: 90 °, electronically, gated with A and B Start up torque: 0.6 Ncm (+20 °C) Maximum operating speed: 6,000 U/min Moment of inertia of the rotor: 6 gcm² Pulses per revolution: 1,000 MTTFd: mean time to dangerous failure: 600 a (EN I
Specification: Part Number 1035582 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Mass: 0.18 kg EMC: EN 61000-6-2, EN 61000-6-3 Max. angular acceleration: 3,6 x 10^9 rad/s² Operating torque: 0.4 Ncm (+20 °C) Connection type: Cable, universal, 3 m Bearing lifetime: 2 x 10^9 revolutions Shaft diameter: 8 mm x 13 mm MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Referen
Specification: Part Number 1035581 Error limits non-binary number of lines: 0.13 ° Working temperature range: 0 °C ... +60 °C Supply voltage: 4.5 V ... 5.5 V Operating torque: 0.4 Ncm (+20 °C) Pulses per revolution: 2,000 Reference signal, number: 1 Protection class standard: IEC 60529 Moment of inertia of the rotor: 6 gcm² Bearing lifetime: 2 x 10^9 revolutions Maximum output frequency: 200 kHz
Specification: Part Number 1034647 Mechanical interface: Solid shaft, Face mount flange Shaft diameter: 8 mm x 13 mm Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Max. angular acceleration: 3,6 x 10^9 rad/s² Reference signal, number: 1 Measuring step deviation at non binary number of lines: 0.07 ° Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, universal, 0.5 m Permissible shaft loading radial/a
Specification: Part Number 1034648 Moment of inertia of the rotor: 6 gcm² Supply voltage: 10 V ... 30 V Measuring step deviation at non binary number of lines: 0.07 ° Pulses per revolution: 20 Air humidity: 90 % Maximum operating speed: 6,000 U/min Operating power consumption (no load): 40 mA Reference signal, position: 90 °, electronically, gated with A and B Operating torque: 0.4 Ncm (+20 °C) Ini
Specification: Part Number 1034649 Working temperature range: 0 °C ... +60 °C Error limits non-binary number of lines: 0.13 ° Operating power consumption (no load): 40 mA Air humidity: 90 % Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Protection class housing side with cable outlet: IP 64 Measuring step: 90 °, Number of lines Measuring step deviation at binary number of lines: 0.035 °
Specification: Part Number 1034650 Shaft diameter: 8 mm x 13 mm Protection class standard: IEC 60529 Permissible shaft loading radial/axial: 40 N, 20 N Output current: 30 mA Max. angular acceleration: 3,6 x 10^9 rad/s² Measuring step deviation at non binary number of lines: 0.07 ° Moment of inertia of the rotor: 6 gcm² Mechanical interface: Solid shaft, Face mount flange Initialization time: 40 s Sta
Specification: Part Number 1034651 Output current: 30 mA Initialization time: 40 s Error limits non-binary number of lines: 0.13 ° Maximum operating speed: 6,000 U/min Shaft diameter: 8 mm x 13 mm Pulses per revolution: 200 Measuring step: 90 °, Number of lines Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Connection type: Cable, universal, 0.5 m Measuring step deviation at binary number of lines:
Specification: Part Number 1034652 Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, universal, 0.5 m Air humidity: 90 % Measuring step deviation at non binary number of lines: 0.07 ° Supply voltage: 10 V ... 30 V Error limits binary number of lines: 0.09 ° EMC: EN 61000-6-2, EN 61000-6-3 Maximum output frequency: 200 kHz Error limits non-binary number of lines: 0.13 ° Start up torque: 0.6 Ncm
Specification: Part Number 1034653 Pulses per revolution: 256 Storage temperature range: -40 °C ... +70 °C, without package Working temperature range: 0 °C ... +60 °C Initialization time: 40 s Max. angular acceleration: 3,6 x 10^9 rad/s² Measuring step deviation at non binary number of lines: 0.07 ° Bearing lifetime: 2 x 10^9 revolutions Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, univers
Specification: Part Number 1034654 Reference signal, position: 90 °, electronically, gated with A and B Measuring step: 90 °, Number of lines Operating torque: 0.4 Ncm (+20 °C) Protection class housing side with cable outlet: IP 64 Protection class standard: IEC 60529 Connection type: Cable, universal, 0.5 m Reference signal, number: 1 Initialization time: 40 s EMC: EN 61000-6-2, EN 61000-6-3 Storage
Specification: Part Number 1034655 Error limits binary number of lines: 0.09 ° MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Protection class shaft side: IP 64 Measuring step deviation at non binary number of lines: 0.07 ° Air humidity: 90 % Measuring step deviation at binary number of lines: 0.035 ° Shaft diameter: 8 mm x 13 mm Permissible shaft loading radial/axial: 40 N, 20 N Operati
Specification: Part Number 1034656 Measuring step deviation at binary number of lines: 0.035 ° EMC: EN 61000-6-2, EN 61000-6-3 MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Max. angular acceleration: 3,6 x 10^9 rad/s² Pulses per revolution: 512 Maximum operating speed: 6,000 U/min Error limits binary number of lines: 0.09 ° Reference signal, number: 1 Electrical interface: 10 V ... 30 V
Specification: Part Number 1034657 Mass: 0.18 kg Working temperature range: 0 °C ... +60 °C Operating torque: 0.4 Ncm (+20 °C) Measuring step deviation at binary number of lines: 0.035 ° Moment of inertia of the rotor: 6 gcm² Measuring step deviation at non binary number of lines: 0.07 ° Output current: 30 mA Storage temperature range: -40 °C ... +70 °C, without package Reference signal, position:
Specification: Part Number 1034658 Measuring step: 90 °, Number of lines Maximum output frequency: 200 kHz Max. angular acceleration: 3,6 x 10^9 rad/s² Reference signal, position: 90 °, electronically, gated with A and B EMC: EN 61000-6-2, EN 61000-6-3 Permissible shaft loading radial/axial: 40 N, 20 N Start up torque: 0.6 Ncm (+20 °C) Storage temperature range: -40 °C ... +70 °C, without package Conn
Specification: Part Number 1034659 Initialization time: 40 s Error limits non-binary number of lines: 0.13 ° Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Maximum output frequency: 200 kHz Operating power consumption (no load): 40 mA Shaft diameter: 8 mm x 13 mm Permissible shaft loading radial/axial: 40 N, 20 N Mechanical interface: Solid shaft, Face mount flange Operating torque: 0.4