SICK - Distance sensors

Image
Part Number
Description
Specification: Part Number 1028246 Typ. light spot size (distance): 130 mm (at 70 m) 270 mm (at 150 m) 360 mm (at 220 m) Connection type: Male connector, 1 x M12, 4-pin, 1 x M12, 8-pin Light source : Laser, red Effect of air pressure: 0.3 ppm/hPa Protection class : II Power consumption: At 24 V DC < 1,000 mA Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 Output current
Specification: Part Number 1025244 Power consumption: At 24 V DC < 250 mA Output current IA : &le; 100 mA Electromagnetic compatibility (EMC): EN 61000-6-2, EN 55011 Repeatability : 2 mm Typ. light spot size (distance): 130 mm (at 70 m) 270 mm (at 150 m) 360 mm (at 220 m) Resolution: 0.05 mm ... 5 mm Effect of air pressure: 0.3 ppm/hPa Measuring range : 0.15 m ... 300 m, on reflective tape "Diamond Grade"
Specification: Part Number 1025245 Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 Resolution: 0.05 mm ... 5 mm Data interface: PROFIBUS DP Effect of air temperature: 1 ppm/K Max. movement speed: 10 m/s Indication: Display Light source : Laser, red Multifunctional input (MF) : 1 x MF Ripple : < 5 Vpp Enclosure rating: IP 65 Temperature drift: Typ. 0.1 mm/K
Specification: Part Number 1025252 Protection class : II Resolution: 0.05 mm ... 5 mm Effect of air temperature: 1 ppm/K Light source : Laser, red Max. movement speed: 10 m/s Ambient temperature: Operation: -10 ... 55 °C Operation with cooling case: -10 ... 75 °C Storage: -25 ... 75 °C Laser class: 2 (EN 60825-1 / CDRH) Initialization time : 1.5 s Data interface: RS-422 Supply voltage Vs: DC 18 V ..
Specification: Part Number 1026002 Accuracy: ± 5 mm Typ. light spot size (distance): 130 mm (at 70 m) 270 mm (at 150 m) 360 mm (at 220 m) Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 Repeatability : 2 mm Measuring range : 0.15 m ... 300 m, on reflective tape "Diamond Grade" Initialization time : 1.5 s Ambient temperature: Operation: -10 ... 55 °C Operation with coolin
Specification: Part Number 1026003 Data interface: DeviceNet Measuring range : 0.15 m ... 300 m, on reflective tape "Diamond Grade" Light source : Laser, red Initialization time : 1.5 s Weight: Ca. 1,650 g Typ. light spot size (distance): 130 mm (at 70 m) 270 mm (at 150 m) 360 mm (at 220 m) Supply voltage Vs: DC 18 V ... 30 V, limit values Power consumption: At 24 V DC < 250 mA Ripple : < 5 Vpp Electr
Specification: Part Number 1025246 Laser class: 2 (EN 60825-1 / CDRH) Connection type: Male connector, M16, 8-pin Measuring range : 0.15 m ... 300 m, on reflective tape "Diamond Grade" Ambient temperature: Operation with heating: -40 ... 55 °C Operation with cooling case: -40 ... 75 °C Storage: -25 ... 75 °C Temperature drift: Typ. 0.1 mm/K Repeatability : 2 mm Data interface: SSI Typ. light spot size (dist
Specification: Part Number 1025247 Temperature drift: Typ. 0.1 mm/K Output current IA : &le; 100 mA Ripple : < 5 Vpp Connection type: Male connector, 2 x M12, 5-pin, B-coded, 1 x M16, 8-pin, B-coded Protection class : II Indication: Display Ambient temperature: Operation with heating: -40 ... 55 °C Operation with cooling case: -40 ... 75 °C Storage: -25 ... 75 °C Mechanical load: Noise: EN 600 68-2-64 Shoc
Specification: Part Number 1025253 Data interface: RS-422 Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 Connection type: Male connector, M16, 8-pin Resolution: 0.05 mm ... 5 mm Temperature drift: Typ. 0.1 mm/K Switching output : Push-pull: PNP/NPN (100 mA) Protection class : II Max. movement speed: 10 m/s Effect of air temperature: 1 ppm/K Ambient temperature:
Specification: Part Number 1027607 Initialization time: 6 s Cycle time: 5,120 per sec. Power consumption : &le; 6 W Supply voltage Vs: DC 18 V ... 30 V, limit values Weight: Ca. 1,200 g Switching output : Q1, Q2 Typ. light spot size (distance): 20 mm (+ 5 x distance in m) Data interface : RS-422 RS-232 Light source: Laser, infrared Response time : 1 ms ... 600 ms Enclosure rating: IP 65 Outpu
Specification: Part Number 1027608 Data interface: PROFIBUS DP Resolution: &le; 1 mm Accuracy : ± 10 mm Weight: Ca. 1,200 g Electromagnetic compatibility (EMC): EN 55011:1998 Kl. B, Gr.1 / EN 6100-6-2:1999 Mechanical load: Shock: IEC 60068-2-27, -2-29 Sine: IEC 60068-2-6 Cycle time: 5,120 per sec. Protection class : III Output current IA: 100 mA Enclosure rating: IP 65 Laser class: 1 (EN 6082
Specification: Part Number 1027603 Resolution: &le; 1 mm Measuring range: 0.5 m ... 155 m, 90 % remision 0.5 m ... 40 m, 6 % remission 0.5 m ... 65 m, 18 % remission Aperture delay time: 1 s Output current IA: 100 mA Power consumption : &le; 6 W Protection class : III Accuracy : ± 10 mm Analog output: 4 mA ... 20 mA, scalable Electromagnetic compatibility (EMC): EN 55011:1998 Kl. B, Gr.1 / EN 61000-6-2
Specification: Part Number 1027605 Enclosure rating: IP 65 Aperture delay time: 1 s Cycle time: 1,024 per sec. Output current IA: 100 mA Power consumption : &le; 6 W Repeatability : 10 mm, 7 mm Note: Mechanical aperture Light source: Laser, infrared Special characteristic: Mechanical aperture Switching output : Q1, Q2 Measuring range : 0.5 m ... 20 m Interface for parametrization: RS-232 An
Specification: Part Number 1027604 Ripple : < 5 Vpp Supply voltage Vs: DC 18 V ... 30 V, limit values Typ. light spot size (distance): 20 mm (+ 5 x distance in m) Output current IA: 100 mA Electromagnetic compatibility (EMC): EN 55011:1998 Kl. B, Gr.1 / EN 61000-6-2 Initialization time: 6 s Weight: Ca. 1,200 g Ambient temperature: Operation with cooling case: -10 ... +75 °C Operation: -10 ... +55 °C Storage
Specification: Part Number 1027606 Power consumption : &le; 6 W Protection class : III Note: Mechanical aperture Cycle time: 1,024 per sec. Average depth: 1/16/64/256/1,024 Laser class: 1 (EN 60825-1:Nov.2001, IEC 60825-1:ÄM2:2001) Output current IA: 100 mA Weight: Ca. 1,200 g Repeatability : 10 mm, 7 mm Response time : 1 ms ... 4,000 ms Switching output : Q1, Q2 Initialization time: 6 s
Specification: Part Number 1028540 Average depth: 1/16/64/256/1,024 Initialization time: 6 s Weight: Ca. 1,200 g Protection class : III Data interface : RS-422 RS-232 Repeatability : 10 mm, 7 mm Enclosure rating: IP 65 Ripple : < 5 Vpp Power consumption : &le; 6 W Temperature drift : Typ. 0.3 mm/K Typ. 0.6 mm/K Electromagnetic compatibility (EMC): EN 55011:1998 Kl. B, Gr.1 / EN 61000-6-2
Specification: Part Number 1057659 Response time : 2.5 ms / 6.5 ms / 12.5 ms / 24.5 ms / 96.5 ms Data interface: IO-Link Laser service life (MTTF at 25 °C): 100,000 h Additional function: Set speed: Super Fast ... Super Slow IO-Link Reset to factory default Switching mode: Distance to reflective tape (DtR) / switching window (Wnd) / object between sensor and background (ObSB) Multifunctional input: laser off / external
Specification: Part Number 1057660 Typ. ambient light safety: 40 klx Power consumption : &le; 1.7 W Response time : 2.5 ms / 6.5 ms / 12.5 ms / 24.5 ms / 96.5 ms Accuracy : Typ. ± 15 mm Connection type: Male connector, M12, 5-pin Enclosure rating: IP 65, IP 67 Initialization time: &le; 500 ms Ambient temperature : Operation: -30 ... +55 °C, Storage: -40 ... +75 °C Measuring range : 200 mm ... 35,000 m
Specification: Part Number 1057655 Weight: 65 g Connection type: Male connector, M12, 5-pin Data interface: IO-Link Response time : 2.5 ms / 6.5 ms / 12.5 ms / 24.5 ms / 96.5 ms Switching output : 2 x push-pull: PNP/NPN (100 mA), IO-Link Typ. light spot size (distance): 15 mm x 15 mm (at 2 m) Vibration resistance: EN 60068-2-6 / EN 60068-2-64 Laser service life (MTTF at 25 °C): 100,000 h Enclosure r
Specification: Part Number 1057654 Output time : 2 ms / 4 ms / 8 ms / 16 ms / 64 ms Laser service life (MTTF at 25 °C): 100,000 h Multifunctional input (MF) : 1 x Ripple : &le; 5 Vpp Resolution: 0.1 mm Switching output : 2 x push-pull: PNP/NPN (100 mA), IO-Link Hysteresis : 0 mm ... 11,950 mm Indication: LEDs Ambient temperature : Operation: -30 ... +55 °C, Storage: -40 ... +75 °C Data interface:
Specification: Part Number 1057656 Typ. ambient light safety: 40 klx Switching frequency : 333 Hz / 100 Hz / 50 Hz / 25 Hz / 6 Hz Warm-up time: &le; 20 min Protection class: III Data interface: IO-Link Housing material: Plastic (ABS and PC) acrylic glass (PMMA) Ambient temperature : Operation: -30 ... +55 °C, Storage: -40 ... +75 °C Repeatability : 0.5 mm ... 5 mm Initialization time: &le; 500 ms
Specification: Part Number 1047404 Vibration resistance: EN 60068-2-6 / EN 60068-2-64 Warm-up time: &le; 15 min Enclosure rating: IP 65 Housing material: Die-cast zinc housing (ZNAL4CU1) acrylic glass (PMMA) Weight: 200 g Repeatability : 5 mm / 2.5 mm Typ. ambient light safety: 40 klx Response time : 10 ms / 50 ms Switching frequency : 50 Hz / 10 Hz Resolution : 1 mm Additional function: Switch-o
Specification: Part Number 1047406 Shock resistance: EN 60068-2-27 Response time : 20 ms / 100 ms Ripple : &le; 5 Vpp Additional function: Switch-off display Unique measurement value Set switching mode: Distance to object (DtO) / switching window (Wnd) / Object Between Sensor and Background (ObSB) Set moving average: fast/slow Set hysteresis Crosstalk safety Lock user interface Reset to factory default Teach-in, scaling and i
Specification: Part Number 1047402 Measuring range: 200 mm ... 10,000 mm, 90 % remision 200 mm ... 4,000 mm, 6 % remission 200 mm ... 6,000 mm, 18 % remission Protection class: III Ambient temperature: Operation: -30 ... +65 °C, Storage: -40 ... +75 °C Switching frequency : 50 Hz / 10 Hz Switching output : 2 x PNP (100 mA) Accuracy : ± 10 mm Typ. ambient light safety: 40 klx Warm-up time: &le; 15 min A
Specification: Part Number 1047405 Max. rel. humidity (not condensing): &le; 95 % Typ. light spot size (distance): 15 mm x 15 mm (10 m) Accuracy : ± 10 mm Warm-up time: &le; 15 min Laser service life (MTTF at 25 °C): 100,000 h Shock resistance: EN 60068-2-27 Switching frequency : 25 Hz / 5 Hz Connection type: Male connector, M12, 5-pin Hysteresis: 1 mm ... 9,999 mm Ripple : &le; 5 Vpp Supply volt
Specification: Part Number 1040481 Response time: 150 ms Enclosure rating: IP 65 Hysteresis: ± 6 % Measuring range : 0.2 m ... 7 m, 6 % ... 90 % remission Typ. light spot size (distance): 10 mm (at 7 m) 100 mm (at 70 m) 45 mm (at 30 m) Weight: 1,000 g Resolution: &le; 1 mm Connection type: Male connector, M12, 5-pin Laser class: 2 (EN 60825/21 CFR 1.040) Initialization time: 500 ms Accuracy: ± 3
Specification: Part Number 1040483 Hysteresis: ± 6 % Electromagnetic compatibility (EMC): EN 61000-6-2, EN 55011 / EN 60947-5-7: 2003-9 Enclosure rating: IP 65 Light source : Laser, red Power consumption: Typ. 3 W Initialization time: 500 ms Resolution: &le; 1 mm Measuring range: 0.2 m ... 30 m, 90 % remision 0.2 m ... 70 m, 90 % remision Temperature drift: Typ. 0.05 mm/K Typ. light spot size (distance
Specification: Part Number 1026519 Accuracy: ± 3 mm Connection type: Male connector, M12, 5-pin Switching output : PNP ( < 100 mA) Hysteresis: ± 6 % Temperature drift: Typ. 0.05 mm/K Response time: 250 ms Electromagnetic compatibility (EMC): EN 61000-6-2, EN 55011 / EN 60947-5-7: 2003-9 Ambient temperature: Operation: -10 ... +50 °C Operation with cooling case: -10 ... +75 °C Storage: -25 ... +75 °C Su
Specification: Part Number 1026520 Laser class: 2 (EN 60825/21 CFR 1.040) Protection class : II Multifunctional input (MF) : < 2 V Initialization time: 500 ms Switching output : PNP ( < 100 mA) Connection type: Male connector, M12, 5-pin Weight: 1,000 g Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 Accuracy: ± 3 mm Measuring range: 0.2 m ... 18 m, 90 % remision 0.2
Specification: Part Number 1040477 Light source : Laser, red Resolution: &le; 1 mm Measuring range : 0.2 m ... 7 m, 6 % ... 90 % remission Protection class : II Ambient temperature: Operation: -10 ... +50 °C Operation with cooling case: -10 ... +75 °C Storage: -25 ... +75 °C Hysteresis: ± 6 % Typ. light spot size (distance): 10 mm (at 7 m) 100 mm (at 70 m) 45 mm (at 30 m) Switching output : PNP ( < 100 mA)
Menu
Mail Us
enquiry@onstocktrading.com