SICK - DFS60

Image
Part Number
Description
Specification: Part Number 1053003 Initialization time: 40 ms Storage temperature range: -40 °C ... +100 °C, without package Permissible shaft loading radial/axial: 40 N (axial), 80 N (radial) Error limits: ± 0.3 ° Shaft diameter: 10 mm x 19 mm Load current max.: 30 mA Operating voltage range: 10 V ... 32 V Reference signal, position: 90 °, electronically, gated with A and B Power consumption: 0.5 W (
Specification: Part Number 1037760 Mechanical interface: Solid shaft, Face mount flange Maximum output frequency: 300 kHz Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side Permissible shaft loading radial/axial: 40 N (axial), 80 N (radial) Initialization time: 40 ms Operating voltag
Specification: Part Number 1037724 Operating voltage range: 10 V ... 32 V Maximum operating speed: 10,000 /min Measuring step: 90 ° / electronically/number of lines Power consumption: 0.5 W (without load) Max. angular acceleration: 500,000 rad/s² Moment of inertia of the rotor: 6.2 gcm² Bearing lifetime: 3.6 x 10^10 revolutions Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m
Specification: Part Number 1037057 Shaft diameter: 10 mm x 19 mm Start up torque: 0.5 Ncm (+20 °C) Initialization time: 40 ms Bearing lifetime: 3.6 x 10^10 revolutions Storage temperature range: -40 °C ... +100 °C, without package Maximum operating speed: 10,000 /min Mechanical interface: Solid shaft, Face mount flange Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 605
Specification: Part Number 1059000 MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1)
Specification: Part Number 1038230 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Operating torque: 0.3 Ncm (+20 °C) Mass: 0.3 kg MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Working temperature range: 0 °C ... +85 °C Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Beari
Specification: Part Number 1050345 Connection type: Cable, 8-wire, universal, 5 m Pulses per revolution: 2,048 Permissible shaft loading radial/axial: 40 N (axial), 80 N (radial) Start up torque: 0.5 Ncm (+20 °C) Max. angular acceleration: 500,000 rad/s² Moment of inertia of the rotor: 6.2 gcm² Error limits: ± 0.3 ° Reference signal, number: 1 Power consumption: 0.5 W (without load) MTTFd: mean ti
Specification: Part Number 1056467 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Pulses per revolution: 360 Initialization time: 30 ms Operating voltage range: 10 V ... 32 V Resistance to shocks: 50 g (according to EN 60068-2-27) Start up torque: 0.5 Ncm (+20 °C) Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, radial Maximum operating speed: 10
Specification: Part Number 1062158 Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, radial Reference signal, number: 1 Moment of inertia of the rotor: 6.2 gcm² Mass: 0.3 kg Operating voltage range: 10 V ... 32 V Power consumption: 0.7 W (without load) Error limits: ± 0.3 ° Max. angular acceleration: 500,000 rad/s² Pulses per revolution: 1,250 Enclosure rating: IP 65
Specification: Part Number 1053202 Resistance to shocks: 50 g (according to EN 60068-2-27) Mass: 0.2 kg Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Shaft material: Metal Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Shaft diameter: 8 mm Maximum operating speed: 9,000
Specification: Part Number 1052613 Measuring step: 90 ° / electronically/number of lines EMC: (according to EN 61000-6-2 and EN 61000-6-3) Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Max. angular acceleration: 500,000 rad/s² Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Operating voltage range: 10 V ... 32 V Storage temperature range: -
Specification: Part Number 1056925 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Initialization time: 40 ms Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Measuring step deviation: ± 0.2 ° Mass: 0.2 kg Resistance to shocks: 50 g (according to EN 60068-2-27) Maximum operating speed: 9,000 /min Maximum output frequency: 300 kHz MTTFd: mean time to dangerous
Specification: Part Number 1037338 Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Maximum operating speed: 9,000 /min Working temperature range: 0 °C ... +85 °C Measuring step deviation: ± 0.2 ° Max. angular acceleration: 500,000 rad/s² Operating voltage range: 10 V ... 32 V Maximum output frequency: 300 kHz Start up torque: 0.8 Ncm (+20 °C) Load current max.: 30 mA Pulses per re
Specification: Part Number 1053303 Reference signal, position: 90 °, electronically, gated with A and B Shaft material: Metal Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Mass: 0.2 kg Operating voltage range: 10 V ... 32 V Start up torque: 0.8 Ncm (+20 °C) Mechanical interface: Through hollow shaft
Specification: Part Number 1050729 Operating torque: 0.6 Ncm (+20 °C) Connection type: Cable, 8-wire, universal, 1.5 m Load current max.: 30 mA Bearing lifetime: 3.6 x 10^10 revolutions Shaft diameter: 10 mm Reference signal, number: 1 Moment of inertia of the rotor: 40 gcm² Resistance to shocks: 50 g (according to EN 60068-2-27) Measuring step: 90 ° / electronically/number of lines Measuring step d
Specification: Part Number 1058598 Reference signal, position: 90 °, electronically, gated with A and B Pulses per revolution: 1,024 Moment of inertia of the rotor: 40 gcm² Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 1.5 m Connection type: Cable, 8-wire, universal, 1.5 m MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Measuring step deviation: ± 0.2 ° Error l
Specification: Part Number 1036546 Load current max.: 30 mA MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Power consumption: 0.5 W (without load) Connection type: Cable, 8-wire, universal, 5 m Reference signal, number: 1 Max. angular acceleration: 500,000 rad/s² Resistance to shocks: 50 g (according to EN 60068-2-27) Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal
Specification: Part Number 1037537 Shaft material: Metal Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Start up torque: 0.8 Ncm (+20 °C) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Maximum operating speed: 9,000 /min Measuring step: 90 ° / electronically/number of lines Operating voltage range: 4.5 V ... 5.5 V Operating torque: 0.6 Ncm (+20 °C) Reference signal, nu
Specification: Part Number 1037769 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Maximum output frequency: 300 kHz Working temperature range: 0 °C ... +85 °C Shaft material: Metal Resistance to shocks: 50 g (according to EN 60068-2-27) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Maximum operating speed: 9,000 /min Permissible movement axial static/dynamic:
Specification: Part Number 1038106 Mechanical interface: Through hollow shaft Electrical interface: 10 V ... 32 V, HTL/Push pull, Connector M23, 12-pin, radial Shaft diameter: 12 mm EMC: (according to EN 61000-6-2 and EN 61000-6-3) Pulses per revolution: 100 Start up torque: 0.8 Ncm (+20 °C) Reference signal, number: 1 Maximum operating speed: 9,000 /min Moment of inertia of the rotor: 40 gcm² Storage
Specification: Part Number 1053141 Moment of inertia of the rotor: 40 gcm² Power consumption: 0.5 W (without load) Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Working temperature range: 0 °C ... +85 °C Mechanical interface: Through hollow shaft Measuring step deviation: ± 0.2 ° Start up torque: 0.8 Ncm (+20 °C) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Refere
Specification: Part Number 1037117 Error limits: ± 0.3 ° Power consumption: 0.5 W (without load) Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Operating torque: 0.6 Ncm (+20 °C) Shaft material: Metal Resistance to shocks: 50 g (according to EN 60068-2-27) Max. angular acceleration: 500,000 rad/s² Load current m
Specification: Part Number 1052408 Pulses per revolution: 1,024 Initialization time: 40 ms MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Shaft diameter: 12 mm Error limits: ± 0.3 ° Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Measuring step deviation: ± 0.2 ° Mechanical interface: Through hollow shaft Load current max.: 30 mA Maximum output frequency: 300 kHz
Specification: Part Number 1052217 Error limits: ± 0.3 ° Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side Connection type: Male connector M12, 8-pin, radial Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Reference signal, position: 90 °, electronically, gated with
Specification: Part Number 1052427 Shaft diameter: 12 mm Moment of inertia of the rotor: 40 gcm² Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 1.5 m Maximum operating speed: 9,000 /min Initialization time: 40 ms Operating torque: 0.6 Ncm (+20 °C) Resistance to shocks: 50 g (according to EN 60068-2-27) Power consumption: 0.5 W (without load) Mass: 0.2 kg Shaft material:
Specification: Part Number 1038000 Resistance to shocks: 50 g (according to EN 60068-2-27) Reference signal, number: 1 Storage temperature range: -40 °C ... +100 °C, without package Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 1.5 m Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Measuring st
Specification: Part Number 1037419 Measuring step: 90 ° / electronically/number of lines Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Reference signal, position: 90 °, electronically, gated with A and B Reference signal, number: 1 Bearing li
Specification: Part Number 1050305 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Reference signal, position: 90 °, electronically, gated with A and B Start up torque: 0.8 Ncm (+20 °C) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Bearing lifetime: 3.6 x 10^10 revolutions Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Working temperature
Specification: Part Number 1038001 Mechanical interface: Through hollow shaft Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Moment of inertia of the rotor: 40 gcm² EMC: (according to EN 61000-6-2 and EN 61000-6-3) Power consumption: 0.5 W (without load) Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Reference signal, number: 1 Working te
Specification: Part Number 1052611 EMC: (according to EN 61000-6-2 and EN 61000-6-3) Initialization time: 40 ms Error limits: ± 0.3 ° Storage temperature range: -40 °C ... +100 °C, without package Connection type: Cable, 8-wire, universal, 3 m Power consumption: 0.5 W (without load) Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 3 m Measuring step: 90 ° / electronically/numb
Menu
Mail Us
enquiry@onstocktrading.com