Specification: Part Number 1031776 Max. number of revolutions: 1 Measuring step: 360 ° /number of lines Storage temperature range: -40 °C ... 100 °C Operating power consumption (no load): 90 mA Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Electrical interface: Cable, 22-pin, axial, 1.5 m Initialization time: 80 ms Error limits: 0.035 ° (binary number of steps) 0
Specification: Part Number 1031567 Enclosure rating: IP 66, according to IEC 60529 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Measuring step: 360 ° /number of lines Storage temperature range: -40 °C ... 100 °C Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Initialization time: 80 ms Repeat accuracy: 0.005 ° EMC: According to EN
Specification: Part Number 1036299 Storage temperature range: -40 °C ... 100 °C Max. number of steps per revolution: 2,000 Measuring step deviation: 0.005 °, 0.016 ° Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Resistance to shocks: 50 g (according to EN 60068-2-27) Initialization time: 80 ms Measuring step: 360 ° /number of lines Working temperature range: -20
Specification: Part Number 1031764 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Operating power consumption (no load): 90 mA Measuring step deviation: 0.005 °, 0.016 ° Resistance to shocks: 50 g (according to EN 60068-2-27) EMC: According to EN 61000-6-2 and EN 61000-6-3 Electrical interface: Cable, 22-pin, axial, 3 m Working temperature range: -20 °C ... 85 °C O
Specification: Part Number 1032609 Working temperature range: -20 °C ... 85 °C EMC: According to EN 61000-6-2 and EN 61000-6-3 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Initialization time: 80 ms Enclosure rating: IP 66, according to IEC 60529 Operating voltage range: 10 V DC ... 32 V DC Resistance to shocks: 50 g (according to EN 60068-2-27) Resolution power: 32,767 x
Specification: Part Number 1035827 Measuring step deviation: 0.005 °, 0.016 ° Working temperature range: -20 °C ... 85 °C Repeat accuracy: 0.005 ° EMC: According to EN 61000-6-2 and EN 61000-6-3 Operating voltage range: 10 V DC ... 32 V DC Electrical interface: Cable, 22-pin, axial, 5 m Measuring step: 360 ° /number of lines Max. number of steps per revolution: 360 Resolution power: 360 x 1 Permi
Specification: Part Number 1032874 Resistance to shocks: 50 g (according to EN 60068-2-27) Initialization time: 80 ms Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Operating voltage range: 10 V DC ... 32 V DC Storage temperature range: -40 °C ... 100 °C Enclosure rating: IP 66, according to I
Specification: Part Number 1031584 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Measuring step: 360 ° /number of lines Resistance to shocks: 50 g (according to EN 60068-2-27) Storage temperature range: -40 °C ... 100 °C Electrical interface: Cable, 22-pin, axial, 5 m Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) EMC: According to EN 610
Specification: Part Number 1034567 Operating voltage range: 10 V DC ... 32 V DC Working temperature range: -20 °C ... 85 °C Measuring step deviation: 0.005 °, 0.016 ° Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Max. number of revolutions: 1 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Enclosure rating: IP 66, according to IEC
Specification: Part Number 1031765 Max. number of revolutions: 1 Electrical interface: Cable, 22-pin, axial, 5 m Operating power consumption (no load): 90 mA Measuring step deviation: 0.005 °, 0.016 ° Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Operating voltage range: 10 V DC ... 32 V DC Enclosure rating: IP 66, according to IEC 60529 Initialization time: 80 ms
Specification: Part Number 1031641 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Measuring step: 360 ° /number of lines Enclosure rating: IP 66, according to IEC 60529 Electrical interface: Cable, 22-pin, axial, 5 m Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Initialization time: 80 ms Working temperature range: -20 °C ... 85 °C
Specification: Part Number 1035840 Mass: 0.3 kg Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Enclosure rating: IP 65 (according to IEC 60529), with mating connector fitted Start up torque: 0.6 Ncm Mechanical interface: Blind hollow shaft Operating power consumption (no load): 90 mA Bearing lifetime: 3.6 x 10^9 revolutions Resistance to vibration: 20 g, 10 Hz ... 2,00
Specification: Part Number 1032803 Measuring step deviation: 0.005 °, 0.016 ° Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Max. number of revolutions: 1 Operating torque: 0.4 Ncm Operation of zero-set: ≥ 100 ms Maximum operating speed: 3,000 /min Resistance to shocks: 50 g (according to EN 60068-2-27) Repeat accuracy: 0.005 ° Shaft diameter: 6 mm 8 mm 10 mm 1
Specification: Part Number 1209935 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Maximum operating speed: 3,000 /min Working temperature range: -20 °C ... 85 °C EMC: (according to EN 61000-6-2 and EN 61000-6-3) Initialization time: 80 ms Operation of zero-set: ≥ 100 ms Electrical interface: Connector M23, 21-pin, radial Mechanical interface: Blind hollow shaft
Specification: Part Number 1209326 Max. number of steps per revolution: 3,600 Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Repeat accuracy: 0.005 ° Operating torque: 0.4 Ncm Operating power consumption (no load): 90 mA Electrical interface: Connector M23, 21-pin, radial Measuring step deviation: 0.005 °, 0.016 ° Permissible movement radial static/dynamic: ± 0.3 mm,
Specification: Part Number 1034441 Measuring step deviation: 0.005 °, 0.016 ° Operating voltage range: 10 V DC ... 32 V DC Storage temperature range: -40 °C ... 100 °C Mechanical interface: Blind hollow shaft Measuring step: 360 ° /number of lines Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Maximum operating speed: 3,000 /min Bearing lifetime: 3.6 x 10^9 revolu
Specification: Part Number 1031608 EMC: (according to EN 61000-6-2 and EN 61000-6-3) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Working temperature range: -20 °C ... 85 °C Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Storage temperature range: -40 °C ... 100 °C Initialization time: 80 ms Enclosure rating: IP 65 (according to IEC 60529), with m
Specification: Part Number 1031612 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Mass: 0.3 kg Repeat accuracy: 0.005 ° Max. angular acceleration: 500,000 rad/s² Max. number of steps per revolution: 5,760 Max. number of revolutions: 1 Measuring step deviation: 0.005 °, 0.016 ° Resistance to shocks:
Specification: Part Number 1031645 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Working temperature range: -20 °C ... 85 °C Max. number of steps per revolution: 32,768 Electrical interface: Connector M23, 21-pin, radial Enclosure rating: IP 6
Specification: Part Number 1035856 Bearing lifetime: 3.6 x 10^9 revolutions Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Storage temperature range: -40 °C ... 100 °C Mass: 0.3 kg Initialization time: 80 ms Measuring step: 360 ° /number of lines EMC: (according to EN 61000-6-2 and EN 61000-6-3) Shaft diameter: 6 mm 8 mm 1
Specification: Part Number 1037342 Operating voltage range: 10 V DC ... 32 V DC Resolution power: 1,024 x 1 Start up torque: 0.6 Ncm Electrical interface: Connector M23, 21-pin, axial Maximum operating speed: 3,000 /min Shaft diameter: 6 mm 8 mm 10 mm 12 mm 14 mm 15 mm 1/4 " 3/8 " 1/2 " Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Working temperature range: -20 °C ...
Specification: Part Number 1035037 Operating torque: 0.4 Ncm Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Mass: 0.3 kg Shaft diameter: 6 mm 8 mm 10 mm 12 mm 14 mm 15 mm 1/4 " 3/8 " 1/2 " Start up torque: 0.6 Ncm Enclosure rating: IP 65 (according to IEC 60529), with mating connector fitted Operating power consumption (no load):
Specification: Part Number 1031785 Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Measuring step deviation: 0.005 °, 0.016 ° Start up torque: 0.6 Ncm Maximum operating speed: 3,000 /min Operation of zero-set: ≥ 100 ms Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Initialization time:
Specification: Part Number 1031792 Max. number of revolutions: 1 Initialization time: 80 ms Start up torque: 0.6 Ncm Electrical interface: Connector M23, 21-pin, axial EMC: (according to EN 61000-6-2 and EN 61000-6-3) Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Operating voltage range: 10 V DC ... 32 V DC Mechanical interface: Blind hollow shaft Measuring step:
Specification: Part Number 1031559 Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Max. number of steps per revolution: 360 Storage temperature range: -40 °C ... 100 °C Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Max. angular acceleration: 500,000 rad/s² Max. number of revolutions: 1 Working temperature range: -20 °C ... 85 °C Shaft diameter: 6 mm 8 mm 10 mm 12 mm 14 m
Specification: Part Number 1032996 Measuring step deviation: 0.005 °, 0.016 ° Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Start up torque: 0.6 Ncm Operating voltage range: 10 V DC ... 32 V DC Resolution power: 512 x 1 Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm EMC: (according to EN 61000-6-2 and EN 61000-6-3) Electrical interface: Cable, 22-pin
Specification: Part Number 1031576 Resistance to shocks: 50 g (according to EN 60068-2-27) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Start up torque: 0.6 Ncm Electrical interface: Cable, 22-pin, radial, 1.5 m Storage temperature range: -40 °C ... 100 °C Enclosure rating: IP 66 (according to IEC 60529) Maximum operating speed: 3,000 /mi
Specification: Part Number 1034750 Operating power consumption (no load): 90 mA Storage temperature range: -40 °C ... 100 °C Repeat accuracy: 0.005 ° Mechanical interface: Blind hollow shaft Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Operating torque: 0.4 Ncm Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Start up torque: 0.6 Ncm
Specification: Part Number 1035625 Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Enclosure rating: IP 66 (according to IEC 60529) Start up torque: 0.6 Ncm Max. number of steps per revolution: 1,924 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Mechanical interface: Blind hollow shaft MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1
Specification: Part Number 1031593 Operating torque: 0.4 Ncm Electrical interface: Cable, 22-pin, radial, 1.5 m Measuring step: 360 ° /number of lines Measuring step deviation: 0.005 °, 0.016 ° Enclosure rating: IP 66 (according to IEC 60529) Repeat accuracy: 0.005 ° Operating voltage range: 10 V DC ... 32 V DC Operation of zero-set: ≥ 100 ms Resistance to shocks: 50 g (according to EN 60068-2-27)