SICK - AFS60

Image
Part Number
Description
Specification: Part Number AFS60B-TGPK032768 Moment of inertia of the rotor: 40 gcm² Max. number of revolutions: 1 Measuring step: 0.01 ° Bearing lifetime: 3.0 x 10^9 revolutions Interface signals: Clock +, Clock -, Data +, Data- Resolution power: 32,768 x 1 Reverse polarity protection: 1 Error limits: ± 0.05 ° MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) CW/CCW (counting sequence
Specification: Part Number 1061404 Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Initialization time: 50 ms Code type: Gray Max. angular acceleration: 500,000 rad/s² Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Max. number of steps per revolution: 4,096 SET (electronic a
Specification: Part Number 1052259 Resistance to shocks: 70 g, 6 ms (according to EN 60068-2-27) Mechanical interface: Through hollow shaft Repeat accuracy: 0.002 ° Code sequence: CW/CCW, parameter adjustable Reverse polarity protection: 1 MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Connection type: Con
Specification: Part Number 1051522 Shaft diameter: 15 mm Max. angular acceleration: 500,000 rad/s² Working temperature range: -30 °C ... 100 °C Power consumption: 0.5 W (without load) Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Repeat accuracy: 0.002 ° Mechanical interface: Through hollow shaft Permissi
Specification: Part Number 1052297 Bearing lifetime: 3.0 x 10^9 revolutions Resistance to shocks: 70 g, 6 ms (according to EN 60068-2-27) Reverse polarity protection: 1 EMC: (according to EN 61000-6-2 and EN 61000-6-3) Error limits: ± 0.05 ° Power consumption: 0.5 W (without load) Shaft diameter: 15 mm Measuring step deviation: ± 0.01 ° Electrical interface: SSI/Gray, programmable Resistance to vib
Specification: Part Number 1038046 Shaft diameter: 10 mm EMC: (according to EN 61000-6-2 and EN 61000-6-3) Maximum operating speed: 6,000 /min Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Clock frequency: 1 MHz Max. angular acceleration: 500,000 rad/s² Repeat accuracy: 0.002 °
Specification: Part Number 1037985 Code sequence: CW/CCW, parameter adjustable Connection type: Connector M23, 12-pin, radial Clock frequency: 1 MHz Mass: 0.2 kg Maximum operating speed: 6,000 /min Max. number of revolutions: 1 MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Max. number of steps per revolution: 3,600 EMC: (according to EN 61000-6-2 and EN 61000-6-3) Moment of inertia o
Specification: Part Number 1038047 Measuring step deviation: ± 0.2 ° EMC: (according to EN 61000-6-2 and EN 61000-6-3) Measuring step: 0.09 ° 360 ° / number of steps Moment of inertia of the rotor: 40 gcm² MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Electrical interface: SSI/Gray Shaft diameter: 10 mm Reverse polarity protection: 1 CW/CCW (counting sequence when turning): L-active
Specification: Part Number 1038041 Storage temperature range: -40 °C ... 100 °C, without package Resolution power: 4,096 x 1 Type of mounting shaft: Blind hollow shaft Bearing lifetime: 3.0 x 10^9 revolutions Reverse polarity protection: 1 Max. number of steps per revolution: 4,096 Electrical interface: SSI/Gray Code type: Gray Mechanical interface: Blind hollow shaft Enclosure rating: IP 65 (accordi
Specification: Part Number 1038048 Code sequence: CW/CCW, parameter adjustable MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Operating torque: 0.6 Ncm (20 °C) Code type: Gray Initialization time: 50 ms Electrical interface: SSI/Gray Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side Permissible movement axial static/dynamic: ± 0.5 mm,
Specification: Part Number 1038042 Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Moment of inertia of the rotor: 40 gcm² EMC: (according to EN 61000-6-2 and EN 61000-6-3) Max. number of revolutions: 1 Max. angular acceleration: 500,000 rad/s² Interface signals: Clock +, Clock -, Data +, Data- Measuring step deviation: ± 0.2 ° Connection type: Cable, 8-wire, universal, 1.5 m MTTFd: mean
Specification: Part Number 1037942 Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Electrical interface: SSI/Gray Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Max. number of steps per revolution: 1,024 CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Code type: Gray Enclosure rating: IP 65 (according to IEC 605
Specification: Part Number 1038043 Code type: Gray Repeat accuracy: 0.002 ° Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Clock frequency: 1 MHz Resolution power: 4,096 x 1 Error limits: ± 0.3 ° Storage temperature range: -40 °C ... 100 °C, without package Measuring step deviation: ± 0.2 ° Initialization time: 50 ms Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 m
Specification: Part Number 1038049 Interface signals: Clock +, Clock -, Data +, Data- Repeat accuracy: 0.002 ° Max. number of steps per revolution: 1,024 Code sequence: CW/CCW, parameter adjustable Operating torque: 0.6 Ncm (20 °C) Power consumption: 0.5 W (without load) Max. angular acceleration: 500,000 rad/s² Measuring step deviation: ± 0.2 ° Measuring step: 0.09 ° 360 ° / number of steps Max.
Specification: Part Number 1038050 Moment of inertia of the rotor: 40 gcm² Repeat accuracy: 0.002 ° Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Initialization time: 50 ms Code type: Gray Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Start up torque: 0.8 Ncm (20 °C) Electrical interface: SSI/Gray Max. angular acceleration: 500,000 rad/s²
Specification: Part Number 1052661 MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Operating torque: 0.6 Ncm (20 °C) Initialization time: 50 ms Reverse polarity protection: 1 Repeat accuracy: 0.002 ° Measuring step deviation: ± 0.2 ° Electrical interface: SSI/Gray Max. number of revolutions: 1 Max. angular acceleration: 500,000 rad/s² Error limits: ± 0.3 ° Code sequence: CW/C
Specification: Part Number 1050812 Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side Bearing lifetime: 3.0 x 10^9 revolutions Storage temperature range: -40 °C ... 100 °C, without package Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Moment of inertia of the rotor: 40 gcm² Clock frequency: 1 MHz Operating torque
Specification: Part Number 1053735 Interface signals: Clock +, Clock -, Data +, Data- Max. angular acceleration: 500,000 rad/s² CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Operating voltage range: 4.5 V DC ... 32 V DC Code type: Gray Max. number of steps per revolution: 4,096 MTTFd: mean time to da
Specification: Part Number 1051497 SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Power consumption: 0.5 W (without load) Moment of inertia of the rotor: 40 gcm² Measuring step: 0.09 ° 360 ° / number of steps Electrical interface: SSI/Gray CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Code type: Gray Connection type: Cable, 8
Specification: Part Number 1053557 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Operating voltage range: 4.5 V DC ... 32 V DC Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Max. number of steps per revolution: 4,096 Bearing lifetime: 3.0 x 10^9 revolutions Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Permissible movement axial static/dyn
Specification: Part Number 1037626 Initialization time: 50 ms Code sequence: CW/CCW, parameter adjustable Connection type: Male connector M12, 8-pin, radial Power consumption: 0.5 W (without load) Start up torque: 0.5 Ncm (20 °C) Type of mounting shaft: Solid shaft Maximum operating speed: 9,000 /min Reverse polarity protection: 1 Max. angular acceleration: 500,000 rad/s² Clock frequency: 1 MHz
Specification: Part Number 1037627 Shaft diameter: 6 mm Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Operating voltage range: 4.5 V DC ... 32 V DC MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Resolution power: 4,096 x 1 Moment of inertia of the rotor: 6.2 gcm² Connection type: Cable, 8-wire, univer
Specification: Part Number 1037628 Max. angular acceleration: 500,000 rad/s² Connection type: Cable, 8-wire, universal, 3 m Error limits: ± 0.2 ° Measuring step deviation: ± 0.2 ° Operating torque: 0.3 Ncm (20 °C) Maximum operating speed: 9,000 /min Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side Measuring step: 0.09 ° 360 ° / number of steps
Specification: Part Number 1037629 Type of mounting shaft: Solid shaft Clock frequency: 1 MHz Maximum operating speed: 9,000 /min Code sequence: CW/CCW, parameter adjustable Resolution power: 4,096 x 1 Operating torque: 0.3 Ncm (20 °C) Reverse polarity protection: 1 SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) : Servo flange Start up torque: 0.5 Ncm (20 °C) O
Specification: Part Number 1052119 Resolution power: 256 x 1 Connection type: Male connector M12, 8-pin, radial Max. number of revolutions: 1 Measuring step: 0.09 ° 360 ° / number of steps Shaft diameter: 10 mm Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Error limits: ± 0.2 ° Operating voltage range: 4.5 V DC ... 32 V DC Electrical interface: SSI/Gray Sta
Specification: Part Number 1058649 : Face mount flange Moment of inertia of the rotor: 6.2 gcm² Max. number of revolutions: 1 Mechanical interface: Solid shaft with flat, Face mount flange Type of mounting shaft: Solid shaft with flat Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Storage temperature range: -40 °C ... 100 °C, without package MTTFd: mean time to dangerous failure: 250 a (EN IS
Specification: Part Number 1037633 Mechanical interface: Solid shaft with flat, Face mount flange Resolution power: 4,096 x 1 Error limits: ± 0.2 ° Shaft diameter: 10 mm EMC: (according to EN 61000-6-2 and EN 61000-6-3) Interface signals: Clock +, Clock -, Data +, Data- Initialization time: 50 ms Connection type: Cable, 8-wire, universal, 3 m Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (accordin
Specification: Part Number 1052319 Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side Interface signals: Clock +, Clock -, Data +, Data- Storage temperature range: -40 °C ... 100 °C, without package Code sequence: CW/CCW, parameter adjustable EMC: (according to EN 61000-6-2 and EN 61000-6-3) Measuring step: 0.09 ° 360 ° / number of steps Bearing lifetime:
Specification: Part Number 1038887 Resolution power: 1,024 x 1 Electrical interface: SSI/Gray Initialization time: 50 ms Reverse polarity protection: 1 Max. number of steps per revolution: 1,024 Repeat accuracy: 0.002 ° Clock frequency: 1 MHz MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Maximum operating speed: 9,000 /min Error limits: ± 0.2 ° Operating voltage range: 4.5 V
Specification: Part Number 1038057 Interface signals: Clock +, Clock -, Data +, Data- Shaft diameter: 10 mm MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Start up torque: 0.8 Ncm (20 °C) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Type of mounting shaft: Through hollow shaft Measuring step: 0.09 ° 360 ° / number of steps Max. angular acceleration: 500,000 rad/s² CW/
Menu
Mail Us
enquiry@onstocktrading.com