Specification: Part Number 1207351 Switching current: 300 mA Automatic beam coding: + Ambient operating temperature: -20 °C ... +55 °C Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Enclosure rating: IP 65 (EN 60529) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Typical range: 0 m ... 5 m Resolution: 34 mm Restart interlock: + Safe state in the event of a fault: At least one OSSD is in the OFF state. Beam coding: + Conductor cross-section: 0.34 mm² Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Shock resistance: 10 g, 16 ms (EN 60068-2-27) Display elements: LEDs Weight: 400 g Protection class: III (EN 61140) Housing material: Aluminum alloy ALMGSI 0.5 PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) External device monitoring (delivery status): Deactivated Cable length: 700 mm TM (mission time): 20 a (EN ISO 13849) Safe SICK device communication via EFI/SDL: - Scanning range: 0 m ... 4 m Permitted cable length: ≤ 20 m Ripple: ≤ 10 % Cascaded: - Air humidity: 15 % ... 95 %, non-condensing Category: Category 4 (EN ISO 13849) Protective field height: 1,140 mm Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching voltage LOW: 2 V DC Synchronization: Optical, without separate synchronization Restart interlock (delivery status): Deactivated External device monitoring (EDM): + Power consumption: ≤ 3 A Performance level: PL e (EN ISO 13849) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Configuration method: Hard wired Connection type: Male connector M12, 5-pin Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Housing cross-section (incl. system connection): 15 mm x 32 mm Storage temperature: -25 °C ... +70 °C Response time: ≤ 13 ms Type: Type 4 (IEC 61496)