Specification: Part Number 1207298 Safe state in the event of a fault: At least one OSSD is in the OFF state. Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) External device monitoring (delivery status): Deactivated Storage temperature: -25 °C ... +70 °C Housing cross-section (incl. system connection): 15 mm x 32 mm Air humidity: 15 % ... 95 %, non-condensing Ripple: ≤ 10 % Performance level: PL e (EN ISO 13849) Resolution: 24 mm Restart interlock: + Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Housing material: Aluminum alloy ALMGSI 0.5 Connection type extension connection: Female connector M12, 5-pin Weight: 400 g Configuration method: Hard wired Cascaded: + Typical range: 0 m ... 5 m External device monitoring (EDM): + Automatic beam coding: + Permitted cable length: ≤ 20 m Protective field height: 1,140 mm Enclosure rating: IP 65 (EN 60529) Ambient operating temperature: -20 °C ... +55 °C Type: Type 4 (IEC 61496) Safe SICK device communication via EFI/SDL: - Power consumption: ≤ 3 A Category: Category 4 (EN ISO 13849) Connection type: Male connector M12, 5-pin Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Conductor cross-section: 0.34 mm² PFHd: Cascaded systems: 1.3 1E-08 (EN ISO 13849) Switching current: 300 mA Cable length: 700 mm Synchronization: Optical, without separate synchronization Restart interlock (delivery status): Deactivated Switching voltage LOW: 2 V DC Beam coding: + Shock resistance: 10 g, 16 ms (EN 60068-2-27) Display elements: LEDs TM (mission time): 20 a (EN ISO 13849) Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Protection class: III (EN 61140) Scanning range: 0 m ... 4 m Response time: ≤ 13 ms