Specification: Part Number 1207110 Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Housing material: Aluminum alloy ALMGSI 0.5 Scanning range: 0 m ... 4 m PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) Ambient operating temperature: -20 °C ... +55 °C Housing cross-section (incl. system connection): 15 mm x 32 mm Switching current: 300 mA Cable length: 700 mm Power consumption: ≤ 3 A Response time: ≤ 17 ms Connection type: Male connector M12, 5-pin Category: Category 4 (EN ISO 13849) Type: Type 4 (IEC 61496) Conductor cross-section: 0.34 mm² Performance level: PL e (EN ISO 13849) Automatic beam coding: + Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Shock resistance: 10 g, 16 ms (EN 60068-2-27) Configuration method: Hard wired Permitted cable length: ≤ 20 m Storage temperature: -25 °C ... +70 °C Safe SICK device communication via EFI/SDL: - Protective field height: 960 mm Synchronization: Optical, without separate synchronization Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Weight: 340 g Restart interlock (delivery status): Deactivated Enclosure rating: IP 65 (EN 60529) Switching voltage LOW: 2 V DC Cascaded: - External device monitoring (delivery status): Deactivated Air humidity: 15 % ... 95 %, non-condensing TM (mission time): 20 a (EN ISO 13849) Ripple: ≤ 10 % External device monitoring (EDM): + Restart interlock: + Beam coding: + Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Display elements: LEDs Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Protection class: III (EN 61140) Safe state in the event of a fault: At least one OSSD is in the OFF state. Typical range: 0 m ... 5 m Resolution: 14 mm