Specification: Part Number 1207255 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Restart interlock: + Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Permitted cable length: ≤ 20 m Housing material: Aluminum alloy ALMGSI 0.5 Configuration method: Hard wired Scanning range: 0 m ... 4 m Conductor cross-section: 0.34 mm² PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) Switching voltage LOW: 2 V DC Ripple: ≤ 10 % Cascaded: - Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Protection class: III (EN 61140) Storage temperature: -25 °C ... +70 °C Response time: ≤ 13 ms Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Weight: 320 g Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Display elements: LEDs External device monitoring (delivery status): Deactivated Performance level: PL e (EN ISO 13849) Resolution: 34 mm Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Cable length: 700 mm TM (mission time): 20 a (EN ISO 13849) Switching current: 300 mA Enclosure rating: IP 65 (EN 60529) Typical range: 0 m ... 5 m Air humidity: 15 % ... 95 %, non-condensing Safe SICK device communication via EFI/SDL: - Ambient operating temperature: -20 °C ... +55 °C Automatic beam coding: + Housing cross-section (incl. system connection): 15 mm x 32 mm Type: Type 4 (IEC 61496) Safe state in the event of a fault: At least one OSSD is in the OFF state. External device monitoring (EDM): + Synchronization: Optical, without separate synchronization Power consumption: ≤ 3 A Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Protective field height: 900 mm Category: Category 4 (EN ISO 13849) Restart interlock (delivery status): Deactivated Beam coding: + Connection type: Male connector M12, 5-pin