Specification: Part Number 1207313 Configuration method: Hard wired Cable length: 700 mm Performance level: PL e (EN ISO 13849) Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Connection type: Male connector M12, 5-pin Beam coding: + Restart interlock: + Ambient operating temperature: -20 °C ... +55 °C Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Restart interlock (delivery status): Deactivated Automatic beam coding: + Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Shock resistance: 10 g, 16 ms (EN 60068-2-27) Weight: 320 g Switching voltage LOW: 2 V DC Conductor cross-section: 0.34 mm² Enclosure rating: IP 65 (EN 60529) Cascaded: + Power consumption: ≤ 3 A Synchronization: Optical, without separate synchronization Response time: ≤ 13 ms Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Resolution: 34 mm Type: Type 4 (IEC 61496) Display elements: LEDs Connection type extension connection: Female connector M12, 5-pin Housing cross-section (incl. system connection): 15 mm x 32 mm Safe state in the event of a fault: At least one OSSD is in the OFF state. Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Scanning range: 0 m ... 4 m External device monitoring (EDM): + Switching current: 300 mA External device monitoring (delivery status): Deactivated Protective field height: 900 mm Ripple: ≤ 10 % Air humidity: 15 % ... 95 %, non-condensing Storage temperature: -25 °C ... +70 °C Protection class: III (EN 61140) Permitted cable length: ≤ 20 m PFHd: Cascaded systems: 1.3 1E-08 (EN ISO 13849) Housing material: Aluminum alloy ALMGSI 0.5 Category: Category 4 (EN ISO 13849) Typical range: 0 m ... 5 m Safe SICK device communication via EFI/SDL: - TM (mission time): 20 a (EN ISO 13849)