Schneider Electric

Image
Part Number
Description
MAIN CHARACTERISTICS range of product DOMAE range DOMAE product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB poles description 4P neutral position LEFT network type AC earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE AC rated conditional short-circuit current 3 KA 25 A standards IEC 61008 COMPLEMETARY CHARACTERISTICS device location in system OUTGOER network f
MAIN CHARACTERISTICS range of product DOMAE range DOMAE product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB poles description 4P neutral position LEFT network type AC earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE AC rated conditional short-circuit current 3 KA 40 A standards IEC 61008 COMPLEMETARY CHARACTERISTICS device location in system OUTGOER network f
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 30 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE AC rated breaking and making capacity IM 1250 A 400 V
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 100 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE AC rated breaking and making capacity IM 1250 A 400 V
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 300 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE AC rated breaking and making capacity IM 1250 A 400 V
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 500 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE AC rated breaking and making capacity IM 1250 A 400 V
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 30 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE A SI rated breaking and making capacity IM 1250 A 400
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 300 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE A SI rated breaking and making capacity IM 1250 A 400
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 30 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE A rated breaking and making capacity IM 1250 A 400 V C
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 300 MA earth-leakage protection time delay SELECTIVE earth-leakage protection class TYPE A rated breaking and making capacity IM 1250 A 400 V CONF
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 300 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE A rated breaking and making capacity IM 1250 A 400 V
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 4P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 500 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE A rated breaking and making capacity IM 1250 A 400 V
MAIN CHARACTERISTICS range of product ID RCCB product or component type SCREW SHIELD accessory / separate part category INSULATION ACCESSORY quantity per set SET OF 10 colour GREY COMPLEMETARY CHARACTERISTICS poles description 2P
MAIN CHARACTERISTICS range of product ID RCCB product or component type SCREW SHIELD accessory / separate part category INSULATION ACCESSORY quantity per set SET OF 10 colour GREY COMPLEMETARY CHARACTERISTICS poles description 4P
MAIN CHARACTERISTICS range of product MULTI 9 range of product ID RCCB product or component type OC CONTACT device short name OFSP signal contacts composition 1 C O [Ie] rated operational current 3 A at 380...415 V AC - 50/60 Hz COMPLEMETARY CHARACTERISTICS mounting mode FIXED mounting support DIN RAIL connections - terminals TUNNEL TYPE TERMINAL 2 CABLES 1...1.5 MM FLEXIBLE tightening torque 0.8 N.M product compatibility I
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 2P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 30 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE AC rated breaking and making capacity IM 1250 A 230 V
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 2P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 300 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE AC rated breaking and making capacity IM 1250 A 230 V
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 2P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 30 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE A rated breaking and making capacity IM 1250 A 230 V C
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 2P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 300 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE A rated breaking and making capacity IM 1250 A 230 V
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 2P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 30 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE A SI rated breaking and making capacity IM 1250 A 230
MAIN CHARACTERISTICS range of product ID RCCB range ACTI 9 product name ACTI 9 RCCB ID product or component type RESIDUAL CRRT CCT BRKER RCCB device short name RCCB ID poles description 2P neutral position LEFT [In] rated current 125 A network type AC earth-leakage sensitivity 300 MA earth-leakage protection time delay INSTANTANEOUS earth-leakage protection class TYPE A SI rated breaking and making capacity IM 1250 A 230
MAIN CHARACTERISTICS range of product MODICON MOMENTUM AUTO PLATFORM product or component type ANALOGUE INPUT BASE analogue input number 8 analogue input type DIFFERENTIAL analogue input range +- 20 MA 14 BITS + SIGN 250 KOHM COMPLEMETARY CHARACTERISTICS data format FULL 16 BITS SIGNED absolute accuracy error +- 0.13 FULL SCALE 25 C 1...5 V conversion time = 80 DB BETWEEN CHANNELS TO GROUND external power requirement < 382 M
MAIN CHARACTERISTICS range of product MODICON MOMENTUM AUTO PLATFORM product or component type ANALOGUE INPUT BASE analogue input number 16 analogue input type SINGLE-ENDED analogue input range 4..20 MA 12 BITS < 0.25 OHM type of filter LOW PASS INPUT FILTER 10 KHZ COMPLEMETARY CHARACTERISTICS data format FULL 16 BITS SIGNED absolute accuracy error +- 0.15 OF FULL SCALE 25 C +- 10 V temperature drift 30 OFSDC +- 10 V 60 DC f
MAIN CHARACTERISTICS range of product MODICON MOMENTUM AUTO PLATFORM product or component type ANALOGUE INPUT BASE analogue input number 4 analogue input type DIFFERENTIAL analogue input range +- 100 MV 15 BITS + SIGN > 10000 KOHM thermocouple type THERMOCOUPLE B COMPLEMETARY CHARACTERISTICS data format FULL 16 BITS SIGNED absolute accuracy error +- 21 V 25 DC +- 25 MV temperature probe type NI 100 0.125 MA +- 25 MV update tim
MAIN CHARACTERISTICS range of product MODICON MOMENTUM AUTO PLATFORM product or component type ANALOGUE OUTPUT BASE COMPLEMETARY CHARACTERISTICS analogue output number 4 data format FULL 16 BITS SIGNED analogue output range +- 10 V 12 BITS + SIGN >= 1 KOHM load capacitance < 1 F absolute accuracy error +- 0.2 OF FULL SCALE +- 10 V 25 C temperature drift 10 OFSDC +- 10 V 60 DC update time 2 MS full scale 10 V +- 10 V fail s
MAIN CHARACTERISTICS range of product MODICON MOMENTUM AUTO PLATFORM product or component type ANALOGUE OUTPUT BASE COMPLEMETARY CHARACTERISTICS analogue output number 4 data format FULL 16 BITS SIGNED analogue output range +- 10 V 12 BITS + SIGN >= 1 KOHM load capacitance < 1 F absolute accuracy error +- 0.2 OF FULL SCALE +- 10 V 25 C temperature drift 10 OFSDC +- 10 V 60 DC update time 2 MS full scale 10 V +- 10 V fail s
MAIN CHARACTERISTICS range of product MODICON MOMENTUM AUTO PLATFORM product or component type DISCRETE INPUTS BASE DC group of channels 1 GROUP OF 16 INPUTS discrete input number 16 IEC 1131-2 TYPE 1 discrete input voltage 24 V DC protective treatment TC COMPLEMETARY CHARACTERISTICS discrete input logic POSITIVE input voltage limits 24 V voltage range - 3..30 V voltage state 0 guaranteed -3...5 V voltage state 1 guaranteed
MAIN CHARACTERISTICS range of product MODICON MOMENTUM AUTO PLATFORM product or component type DISCRETE INPUTS BASE DC group of channels 2 GROUPS OF 16 INPUTS discrete input number 32 IEC 1131-2 TYPE 1 discrete input voltage 24 V DC protective treatment TC COMPLEMETARY CHARACTERISTICS discrete input logic POSITIVE input voltage limits 24 V voltage range - 3..30 V voltage state 0 guaranteed -3...5 V voltage state 1 guaranteed
MAIN CHARACTERISTICS range of product MODICON MOMENTUM AUTO PLATFORM product or component type DISCRETE INPUTS BASE AC group of channels 2 GROUPS OF 8 INPUTS discrete input number 16 IEC 1131-2 TYPE 2 discrete input voltage 120 V AC protective treatment TC COMPLEMETARY CHARACTERISTICS discrete input logic POSITIVE input voltage limits 85..132 V network frequency 47..63 HZ voltage range 0..132 V voltage state 0 guaranteed =
MAIN CHARACTERISTICS range of product MODICON MOMENTUM AUTO PLATFORM product or component type DISCRETE INPUTS BASE AC group of channels 2 GROUPS OF 8 INPUTS discrete input number 16 IEC 1131-2 TYPE 2 discrete input voltage 230 V AC protective treatment TC COMPLEMETARY CHARACTERISTICS discrete input logic POSITIVE input voltage limits 164..253 V network frequency 47..63 HZ voltage range 163..253 V voltage state 0 guaranteed
Menu
Mail Us
enquiry@onstocktrading.com