MAIN CHARACTERISTICS range EASYPACT product name EASYPACT TVS product or component type DIFF THERMAL OVERLOAD RELAY device short name LRE relay application MOTOR PROTECTION phase failure sensitivity tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 COMPLEMETARY CHARACTERISTICS product compatibility LC1E300..630 network type AC network frequency 50..60 HZ mounting support UNDER CONTACTOR
MAIN CHARACTERISTICS range EASYPACT product name EASYPACT TVS product or component type DIFF THERMAL OVERLOAD RELAY device short name LRE relay application MOTOR PROTECTION phase failure sensitivity tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 COMPLEMETARY CHARACTERISTICS product compatibility LC1E400..630 network type AC network frequency 50..60 HZ mounting support UNDER CONTACTOR
MAIN CHARACTERISTICS range EASYPACT product name EASYPACT TVS product or component type DIFF THERMAL OVERLOAD RELAY device short name LRE relay application MOTOR PROTECTION phase failure sensitivity tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 COMPLEMETARY CHARACTERISTICS product compatibility LC1E500..630 network type AC network frequency 50..60 HZ mounting support UNDER CONTACTOR
MAIN CHARACTERISTICS range of product TESYS FUSE CARRIERS device short name LS1D product or component type ROTARY HANDLE accessory / separate part category CONTROL ACCESSORY handle colour BLACK rotary handle mounting style EXTENDED COMPLEMETARY CHARACTERISTICS mounting location RIGHT HAND SIDE rotary handle mounting location LATERAL compatibility code LS1D
MAIN CHARACTERISTICS product name SPACELYNK product or component type LOGIC CONTROLLER COMPLEMETARY CHARACTERISTICS communication port protocol BACNET [Us] rated supply voltage 24 V DC power consumption in W 2 W LED indicator green LED (CPU load) physical interface 1 x RJ45 port Ethernet 10BASE-T 100BASE-TX integrated connection type 1 x USB 2.0 port control type RESET PUSHBUTTON connections - terminals KNX bus : bus termin
MAIN CHARACTERISTICS range of product LT3 device short name LT3SA product or component type THERMISTOR PROTECTION UNITS [Uc] control circuit voltage 24..48 V DC reset AUTOMATIC RESET COMPLEMETARY CHARACTERISTICS control circuit voltage limits 0.8..1.25 UC contacts type and composition 1 NC + 1 NO DUAL VOLTAGE [Ith] conventional free air thermal current 5 A FOR OUTPUT CONTROL RELAY [Ui] rated insulation voltage 500 V AC OUTPUT C
MAIN CHARACTERISTICS range of product LT3 device short name LT3SE product or component type THERMISTOR PROTECTION UNITS [Uc] control circuit voltage 24 V DC reset AUTOMATIC RESET COMPLEMETARY CHARACTERISTICS control circuit voltage limits 0.8..1.25 UC contacts type and composition 1 NC SINGLE VOLTAGE [Ith] conventional free air thermal current 5 A FOR OUTPUT CONTROL RELAY [Ui] rated insulation voltage 500 V AC OUTPUT CONTROL RE
MAIN CHARACTERISTICS range of product LT3 device short name LT3SE product or component type THERMISTOR PROTECTION UNITS [Uc] control circuit voltage 115 V AC 5060 HZ reset AUTOMATIC RESET COMPLEMETARY CHARACTERISTICS control circuit voltage limits 0.85..1.1 UC contacts type and composition 1 NC SINGLE VOLTAGE [Ith] conventional free air thermal current 5 A FOR OUTPUT CONTROL RELAY [Ui] rated insulation voltage 500 V AC OUTPUT C
MAIN CHARACTERISTICS range of product LT3 device short name LT3SE product or component type THERMISTOR PROTECTION UNITS [Uc] control circuit voltage 230 V AC 5060 HZ reset AUTOMATIC RESET COMPLEMETARY CHARACTERISTICS control circuit voltage limits 0.85..1.1 UC contacts type and composition 1 NC SINGLE VOLTAGE [Ith] conventional free air thermal current 5 A FOR OUTPUT CONTROL RELAY [Ui] rated insulation voltage 500 V AC OUTPUT C
MAIN CHARACTERISTICS range of product LT3 device short name LT3SE product or component type THERMISTOR PROTECTION UNITS [Uc] control circuit voltage 24..48 V AC 5060 HZ reset MANUAL COMPLEMETARY CHARACTERISTICS control circuit voltage limits 0.85..1.1 UC contacts type and composition 1 NC + 1 NO SINGLE VOLTAGE [Ith] conventional free air thermal current 5 A FOR OUTPUT CONTROL RELAY [Ui] rated insulation voltage 500 V AC OUTPUT
MAIN CHARACTERISTICS range of product LT3 device short name LT3SE product or component type THERMISTOR PROTECTION UNITS [Uc] control circuit voltage 24..48 V DC reset MANUAL COMPLEMETARY CHARACTERISTICS control circuit voltage limits 0.8..1.25 UC contacts type and composition 1 NC + 1 NO DUAL VOLTAGE [Ith] conventional free air thermal current 5 A FOR OUTPUT CONTROL RELAY [Ui] rated insulation voltage 500 V AC OUTPUT CONTROL RE
MAIN CHARACTERISTICS range of product LT3 device short name LT3SM product or component type THERMISTOR PROTECTION UNITS [Uc] control circuit voltage 115..230 V AC 5060 HZ reset MANUAL COMPLEMETARY CHARACTERISTICS control circuit voltage limits 0.85..1.1 UC contacts type and composition 1 NC + 1 NO DUAL VOLTAGE [Ith] conventional free air thermal current 5 A FOR OUTPUT CONTROL RELAY [Ui] rated insulation voltage 500 V AC OUTPUT
MAIN CHARACTERISTICS range of product LT3 device short name LT3SM product or component type THERMISTOR PROTECTION UNITS [Uc] control circuit voltage 24..230 V AC 5060 HZ reset MANUAL COMPLEMETARY CHARACTERISTICS control circuit voltage limits 0.85..1.1 UC contacts type and composition 2 CO MULTI VOLTAGE [Ith] conventional free air thermal current 5 A FOR OUTPUT CONTROL RELAY [Ui] rated insulation voltage 500 V AC OUTPUT CONTROL
MAIN CHARACTERISTICS range of product LT3 device short name LT3SM product or component type THERMISTOR PROTECTION UNITS [Uc] control circuit voltage 400 V AC 5060 HZ reset MANUAL COMPLEMETARY CHARACTERISTICS control circuit voltage limits 0.85..1.1 UC contacts type and composition 1 NC + 1 NO SINGLE VOLTAGE [Ith] conventional free air thermal current 5 A FOR OUTPUT CONTROL RELAY [Ui] rated insulation voltage 500 V AC OUTPUT CON
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 24 V AC thermal protection adjustment range 0.5...6 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY CHARAC
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 24 V AC thermal protection adjustment range 0.5...6 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY CHARAC
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 48 V AC thermal protection adjustment range 0.5...6 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY CHARAC
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 48 V AC thermal protection adjustment range 0.5...6 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY CHARAC
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 100..120 V AC thermal protection adjustment range 0.5...6 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 100..120 V AC thermal protection adjustment range 0.5...6 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 200..240 V AC thermal protection adjustment range 0.5...6 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 200..240 V AC thermal protection adjustment range 0.5...6 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 24 V AC thermal protection adjustment range 3...30 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY CHARACT
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 24 V AC thermal protection adjustment range 3...30 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY CHARACT
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 48 V AC thermal protection adjustment range 3...30 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY CHARACT
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 48 V AC thermal protection adjustment range 3...30 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY CHARACT
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 100..120 V AC thermal protection adjustment range 3...30 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY C
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 100..120 V AC thermal protection adjustment range 3...30 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY C
MAIN CHARACTERISTICS range of product TESYS LT ELNC OVER CRRT RELAYS range TESYS product name TESYS LT product or component type ELECTRONIC OVER CURRENT RELAY device short name LT47 device application PROTECTION relay application LCKD ROTOR MECH I>3XISETTING [Us] rated supply voltage 200..240 V AC thermal protection adjustment range 3...30 A [Ui] rated insulation voltage 600 V AC POWER CIRCUIT CONFORMING TO CSA COMPLEMETARY C