MAIN CHARACTERISTICS range EASYPACT product or component type CONTACTOR COIL product compatibility LC1E300 device short name LAEX control circuit type AC 60 HZ STANDARD [Uc] control circuit voltage 440 V AC 60 HZ average resistance 6731 OHM AT 20 DC operating time 40..65 MS CLOSING operating rate
MAIN CHARACTERISTICS range EASYPACT product or component type CONTACTOR COIL product compatibility LC1E300 device short name LAEX control circuit type AC 50 HZ STANDARD [Uc] control circuit voltage 240 V AC 50 HZ average resistance 1968 OHM AT 20 DC operating time 40..65 MS CLOSING operating rate
MAIN CHARACTERISTICS range of product TESYS D range TESYS product or component type CAPACITIVE DELAYED OPENING DVC device short name LAZR product compatibility LC1D09..D80 [Us] rated supply voltage AC COMPLEMETARY CHARACTERISTICS [Uc] control circuit voltage 305 V DC time delay range 0.5...10 S height 77 MM width 55 MM depth 114 MM product weight 0.215 KG compatibility code LAZR
MAIN CHARACTERISTICS range of product TESYS D range TESYS product or component type CAPACITIVE DELAYED OPENING DVC device short name LAZR product compatibility LC1D09..D80 [Us] rated supply voltage AC COMPLEMETARY CHARACTERISTICS [Uc] control circuit voltage 543 V DC time delay range 1...13 S height 77 MM width 55 MM depth 114 MM product weight 0.215 KG compatibility code LAZR
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE device application PROTECTION range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-1 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 13...18 A magnetic tripping current 54...108 A trip unit technology THERMAL-MAGNETIC prot
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-1 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 35...50 A magnetic tripping current 150...300 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE t
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 13...18 A magnetic tripping current 108...216 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 18...25 A magnetic tripping current 150...300 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 23...32 A magnetic tripping current 190...380 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 28...40 A magnetic tripping current 240...480 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 35...50 A magnetic tripping current 300...600 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 45...63 A magnetic tripping current 380...760 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 28...40 A magnetic tripping current 600 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE therma
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 35...50 A magnetic tripping current 750 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE therma
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB1LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC thermal protection adjustment range 45...63 A magnetic tripping current 945 A trip unit technology THERMAL-MAGNETIC protection type PHASE IMBALANCE therma
MAIN CHARACTERISTICS range of product INTEGRAL 63 range TESYS device short name LB6LD product or component type PROTECTION MODULE range compatibility TESYS INTEGRAL CONTACTOR BREAKER poles description 3P utilisation category AC-43 [Ue] rated operational voltage 690 V AC magnetic tripping current 300...600 A trip unit technology MAGNETIC protection type PHASE IMBALANCE COMPLEMETARY CHARACTERISTICS motor power kW 11 KW AT 2
MAIN CHARACTERISTICS range of product TESYS B product or component type CONTACTOR device short name LC1BL contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 1P pole contact composition 1 NO [Ie] rated operational current 800 A
MAIN CHARACTERISTICS range of product TESYS B product or component type CONTACTOR device short name LC1BL contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 2P pole contact composition 2 NO [Ie] rated operational current 800 A
MAIN CHARACTERISTICS range of product TESYS B range TESYS product or component type CONTACTOR device short name LC1BL contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 2P pole contact composition 2 NO [Ie] rated operational current 800 A
MAIN CHARACTERISTICS range of product TESYS B range TESYS product or component type CONTACTOR device short name LC1BL contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 3P pole contact composition 3 NO [Ie] rated operational current 800 A
MAIN CHARACTERISTICS range of product TESYS B range TESYS product or component type CONTACTOR device short name LC1BL contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 3P pole contact composition 3 NO [Ie] rated operational current 800 A
MAIN CHARACTERISTICS range of product TESYS B product or component type CONTACTOR device short name LC1BL contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 3P pole contact composition 3 NO [Ie] rated operational current 800 A
MAIN CHARACTERISTICS range of product TESYS B product or component type CONTACTOR device short name LC1BM contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 2P pole contact composition 2 NO [Ie] rated operational current 1250 A
MAIN CHARACTERISTICS range of product TESYS B range TESYS product or component type CONTACTOR device short name LC1BM contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 2P pole contact composition 2 NO [Ie] rated operational current 1250 A
MAIN CHARACTERISTICS range of product TESYS B product or component type CONTACTOR device short name LC1BM contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 2P pole contact composition 2 NO [Ie] rated operational current 1250 A
MAIN CHARACTERISTICS range of product TESYS B range TESYS product or component type CONTACTOR device short name LC1BM contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 3P pole contact composition 3 NO [Ie] rated operational current 1250 A
MAIN CHARACTERISTICS range of product TESYS B product or component type CONTACTOR device short name LC1BM contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 3P pole contact composition 3 NO [Ie] rated operational current 1250 A
MAIN CHARACTERISTICS range of product TESYS B range TESYS product or component type CONTACTOR device short name LC1BM contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 3P pole contact composition 3 NO [Ie] rated operational current 1250 A
MAIN CHARACTERISTICS range of product TESYS B range TESYS product or component type CONTACTOR device short name LC1BM contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 3P pole contact composition 3 NO [Ie] rated operational current 1250 A
MAIN CHARACTERISTICS range of product TESYS B range TESYS product or component type CONTACTOR device short name LC1BM contactor application MOTOR-HEATING-LIGHTING utilisation category AC-1 control circuit type AC coil type STANDARD poles description 3P pole contact composition 3 NO [Ie] rated operational current 1250 A