MAIN CHARACTERISTICS product or component type LR FILTER CELL range compatibility ALTIVAR 312 product specific application OUTPUT FILTER product compatibility ATV312HD11N4 maximum length of motor cable 100 m shielded cable cable 0.5...4 kHz thermal losses 220 W [In] rated current 33 A COMPLEMETARY CHARACTERISTICS product weight 12.5 KG
MAIN CHARACTERISTICS range of product ALTIVAR product or component type LINE CHOKES product compatibility ATV61HU40M3 - LINE CHOKE - 1 PER DRIVE number of phases SINGLE PHASE range compatibility ALTIVAR 61 device application REDUCTION OF CURRENT HARMONICS value of inductance 2 MH [In] rated current 25 A thermal losses 45 W electrical connection TERMINAL 16 MM AWG 4 1.2...1.4 N.M COMPLEMETARY CHARACTERISTICS power supply fre
MAIN CHARACTERISTICS range of product ALTIVAR product or component type LINE CHOKES product compatibility ATV61HU55M3 - LINE CHOKE - 1 PER DRIVE number of phases SINGLE PHASE range compatibility ALTIVAR 61 device application REDUCTION OF CURRENT HARMONICS value of inductance 1 MH [In] rated current 45 A thermal losses 50 W electrical connection TERMINAL 6 MM AWG 8 0.8...1 N.M COMPLEMETARY CHARACTERISTICS power supply freque
MAIN CHARACTERISTICS range of product ALTIVAR accessory / separate part designation FAN KIT accessory / separate part destination VARIABLE SPEED DRIVE COMPLEMETARY CHARACTERISTICS
MAIN CHARACTERISTICS accessory / separate part category REPLACEMENT PART accessory / separate part type POTENTIOMETER COMPLEMETARY CHARACTERISTICS potentiometer characteristic CNT ROTATIONAL OPERATION internal conversion resistor 22 KOHM
MAIN CHARACTERISTICS range of product ALTIVAR product or component type EMC INPUT FILTER range compatibility ALTIVAR 68 product compatibility ATV68 AT 110 KW 400...500 V product specific application RADIO ITFR INPUT FILTER [In] rated current 300 A thermal losses 40 W network number of phases THREE PHASE COMPLEMETARY CHARACTERISTICS maximum earth leakage current 100 MA AT 400 V 50 HZ TN power supply voltage 400...500 V tolera
MAIN CHARACTERISTICS product or component type DV DT FILTER range compatibility ALTIVAR 68 product specific application OUTPUT FILTER [In] rated current 170 A product compatibility VARIABLE SPEED DRIVE ATV68 WALL MOUNT MOTOR 75 KW 380...480 V 3 PHASES nedded quantity 1 electrical connection copper bar M10 COMPLEMETARY CHARACTERISTICS motor cable length
MAIN CHARACTERISTICS product or component type DV DT FILTER range compatibility ALTIVAR 68 product specific application OUTPUT FILTER [In] rated current 300 A product compatibility VARIABLE SPEED DRIVE ATV68 WALL MOUNT MOTOR 75 KW 380...480 V 3 PHASES nedded quantity 1 electrical connection copper bar M10 COMPLEMETARY CHARACTERISTICS motor cable length
MAIN CHARACTERISTICS range of product ALTIVAR 68 accessory / separate part category MONITORING ACCESSORY accessory / separate part type TERMINAL accessory / separate part destination VARIABLE SPEED DRIVE range compatibility ALTIVAR 68 COMPLEMETARY CHARACTERISTICS kit composition MOUNTING KIT
MAIN CHARACTERISTICS range of product ALTIVAR accessory / separate part designation FAN KIT accessory / separate part category ENCLOSURE ACCESSORY accessory / separate part destination VARIABLE SPEED DRIVE COMPLEMETARY CHARACTERISTICS
MAIN CHARACTERISTICS product or component type RESISTANCE BRAKING UNIT ATV61 range compatibility ALTIVAR 61 maximum braking power 420 KW product compatibility ATV61HC25N4 thermal losses 550 W activation threshold 785 V DC + - 1 PT permanent braking power 200 KW AT 400 V AT CONSTANT POWER AND AT ENGAGE THRESHOLD protection type INTEGRATED THERMAL PROTECTION BY THERMAL PROBE minimum resistor value to associate 1.05 OHM COMPLEMETA
MAIN CHARACTERISTICS product or component type RESISTANCE BRAKING UNIT ATV61 range compatibility ALTIVAR 61 maximum braking power 750 KW product compatibility ATV61HC40N4 thermal losses 750 W activation threshold 785 V DC + - 1 PT permanent braking power 400 KW AT 400 V AT CONSTANT POWER AND AT ENGAGE THRESHOLD protection type INTEGRATED THERMAL PROTECTION BY THERMAL PROBE minimum resistor value to associate 0.7 OHM COMPLEMETAR
MAIN CHARACTERISTICS product or component type RESISTANCE BRAKING UNIT ATV61 range compatibility ALTIVAR 61 maximum braking power 450 KW product compatibility ATV61HC25Y thermal losses 650 W activation threshold 1075 V DC + - 1 PT permanent braking power 300 KW AT 690 V AT CONSTANT POWER AND AT ENGAGE THRESHOLD protection type INTEGRATED THERMAL PROTECTION BY THERMAL PROBE minimum resistor value to associate 2 OHM COMPLEMETARY
MAIN CHARACTERISTICS product or component type RESISTANCE BRAKING UNIT ATV61 range compatibility ALTIVAR 61 maximum braking power 900 KW product compatibility ATV61HC50Y thermal losses 1150 W activation threshold 1075 V DC + - 1 PT permanent braking power 400 KW AT 690 V AT CONSTANT POWER AND AT ENGAGE THRESHOLD protection type INTEGRATED THERMAL PROTECTION BY THERMAL PROBE minimum resistor value to associate 1 OHM COMPLEMETARY
MAIN CHARACTERISTICS product or component type RESISTANCE BRAKING UNIT range compatibility ALTIVAR PROCESS ATV900 maximum braking power 160 KW product compatibility VARIABLE SPEED DRIVE ATV930 WITHOUT BRAKING CHOPPER 110 KW 380...480 V thermal losses 400 W activation threshold 780 V DC + - 1 PT permanent braking power 100 KW AT CONSTANT POWER AND AT ENGAGE THRESHOLD protection type INTEGRATED THERMAL PROTECTION BY THERMAL PROBE m
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 11 A AC permanent braking power 7 KW maximum braking power 7 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 20 A AT 660 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT efficienc
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 20 A AC permanent braking power 13 KW maximum braking power 13 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 30 A AT 690 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT efficie
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 32 A AC permanent braking power 11 KW maximum braking power 22 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 50 A AT 690 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT efficie
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 48 A AC permanent braking power 21.5 KW maximum braking power 33 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 80 A AT 690 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT effic
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 65 A AC permanent braking power 26 KW maximum braking power 45 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 100 A AT 690 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT effici
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 102 A AC permanent braking power 32 KW maximum braking power 70 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 160 A AT 660 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT effic
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 130 A AC permanent braking power 38 KW maximum braking power 90 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 200 A AT 660 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT effic
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 195 A AC permanent braking power 38 KW maximum braking power 135 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 315 A AT 660 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT effi
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 231 A AC permanent braking power 86 KW maximum braking power 160 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 350 A AT 660 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT effi
MAIN CHARACTERISTICS product or component type NETWORK BRAKING UNIT range compatibility ALTIVAR 71 [Us] rated supply voltage 400 V maximum current Irms 289 A AC permanent braking power 120 KW maximum braking power 200 KW COMPLEMETARY CHARACTERISTICS supply circuit type AC associated fuse rating 400 A AT 1000 V supply voltage limits 380...415 V network frequency 40...60 HZ +- 10 overload protection 1.2 X MAXIMUM CURRENT ef