General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Installation conditions A 10 mm Nominal voltage 8 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 15 typ. 5
General specifications Switching element function AC/DC NO/NC Rated operating distance 40 mm Installation non-flush Output polarity AC/DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 20 ... 253 V Operating voltage DC 20 ... 300 V Switching frequency 0 ... 25 Hz Hysteresis typ. 3
General specifications Switching element function AC/DC NO/NC Rated operating distance 40 mm Installation non-flush Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage DC 20 ... 300 V Operating voltage AC 20 ... 253 V Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Short-circuit prot
General specifications Switching element function AC NO/NC Rated operating distance 40 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 3 % Short-circuit protection no Voltage
General specifications Switching element function AC NO/NC Rated operating distance 40 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 3 % Short-circuit protection no Voltage
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reverse polarity protection
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse pol
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse pol
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse pol
General specifications Switching element function NAMUR, NC Rated operating distance 50 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions A 40 mm B 150 mm F 240 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching fre
General specifications Switching element function NAMUR, NC Rated operating distance 50 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions A 40 mm B 150 mm F 240 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching fre
General specifications Switching element function NAMUR, NC Rated operating distance 50 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions A 40 mm B 150 mm F 240 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching fre
General specifications Switching element function AC NO/NC Rated operating distance 50 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 3 % Short-circuit protection no Voltage
General specifications Switching element function AC NO/NC Rated operating distance 50 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage AC 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 3 % Voltage drop less than or equal to 5
General specifications Switching element function DC NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection rev
General specifications Switching element function DC NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection rev
General specifications Switching element function NO contact Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection rev
General specifications Switching element function DC NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 750 Hz Hysteresis typ. 3 % Reverse polarity protection conducting
General specifications Switching element function DC NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 750 Hz Reverse polarity protection conducting Short-circuit protecti
General specifications Switching element function DC NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 750 Hz Hysteresis typ. 3 % Reverse polarity protection conducting
General specifications Switching element function DC NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching fr
General specifications Switching element function DC NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 750 Hz Hysteresis typ. 3 % Reverse polarity protection conducting
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity p
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity
General specifications Switching element function DC NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.5 mm Reduction factor r Al 0.44 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function DC NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.5 mm Reduction factor r Al 0.44 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse