General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse polarity protection reverse pol
General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse polarity protection reverse pol
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse polarity protection reverse pol
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse polarity protection reverse pol
General specifications Switching element function AC NC Rated operating distance 8 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 7.5 % Reverse polarity protection reverse polari
General specifications Switching element function AC NO Rated operating distance 8 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 7.5 % Reverse polarity protection reverse polari
General specifications Switching element function AC NO Rated operating distance 8 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 6.5 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 7.5 % Voltage drop less than or equal to 8 V
General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5%
General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5%
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5%
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5%
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 600 Hz Hysteresis typ. 10 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 2 V Operating current 0 ... 200 mA No-load su
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 600 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 2 V Operating current 0 ... 200 mA No-load sup
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 2000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 2 V Operating current 0 ... 200 mA No-load su
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 600 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 2 V Operating current 0 ... 200 mA No-load sup
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 2000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 2 V Operating current 0 ... 200 mA No-load su
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.22 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.5 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.22 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.5 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.22 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.5 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NAMUR, NC Rated operating distance 1.5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.19 Reduction factor r 304 0.65 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarit