General specifications Switching element function AC/DC NO/NC Rated operating distance 30 mm Installation non-flush Output polarity AC/DC Assured operating distance 0 ... 24.3 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 90 mm x 90 mm x 1 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.1 Reduction factor r 304 0.5 Reduction factor r Brass 0.2 Nominal ratings
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.31 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 5 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % R
General specifications Switching element function NO/NC programmable Rated operating distance 30 mm Installation non-flush Output polarity AS-Interface Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Reduction factor r Brass 0.38 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater
General specifications Switching element function PNP NO Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function NPN NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % R
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % R
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.3 Reduction factor r 304 0.81 Reduction factor r Brass 0.42 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Re
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse p
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse p
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % R
General specifications Switching element function NPN NO Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function NPN NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function PNP NO Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function PNP NO Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function PNP NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function DC NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function PNP NO Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function NAMUR, NC Rated operating distance 30 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.42 Reduction factor r 304 0.79 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 150 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % R
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % R
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % R
General specifications Switching element function NPN NO Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function PNP NO Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function PNP NO Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function NAMUR, NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reverse polarity protection yes Short-circuit
General specifications Switching element function NAMUR, NC Rated operating distance 30 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reverse polarity protection yes Short-circuit
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci