General specifications Switching element function PNP NC Rated operating distance 10 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5% Reverse polarity protection reverse pol
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5% Reverse polarity protection reverse pol
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5% Reverse polarity protection reverse pol
General specifications Switching element function PNP NO Rated operating distance 3 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 2.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP Dual NC Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % R
General specifications Switching element function PNP Dual NC Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % R
General specifications Switching element function Dual (NO) Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 6 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 0.2 % R
General specifications Switching element function Dual (NO) Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 6 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Rev
General specifications Switching element function Dual (NO) Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 6 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 0.2 % R
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.3 mm Reduction factor r Al 0.5 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection al
General specifications Switching element function ---- Rated operating distance 3 mm Installation flush mountable Output polarity switched high Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 %
General specifications Switching element function Dual (NO) Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 6 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. % Reverse
General specifications Switching element function PNP NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.2 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Revers
General specifications Switching element function PNP NC Rated operating distance 3 mm Installation flush mountable Output polarity switched high Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.2 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.2 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.2 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r 304 1 Reduction factor r St37 1.2 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection a
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.2 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 %
General specifications Switching element function AC/DC binary NO Rated operating distance 3 mm Installation flush mountable Output polarity AC/DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.38 Reduction factor r 304 1 Reduction factor r St37 1.04 Nominal ratings Operating voltage 20 ... 253 V AC/DC Switching frequency 25 Hz Hysteresis typ.
General specifications Switching element function AC/DC binary NO Rated operating distance 3 mm Installation flush mountable Output polarity AC/DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.38 Reduction factor r 304 1 Reduction factor r St37 1.04 Nominal ratings Operating voltage 20 ... 253 V AC/DC Switching frequency 25 Hz Hysteresis typ.
General specifications Switching element function Dual (NO) Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 6 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Rev
General specifications Switching element function PNP Dual NO Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 6 ... 60 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Re
General specifications Switching element function Dual (NO) Rated operating distance 3 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.1 Nominal ratings Operating voltage 6 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Rev