PEPPERL+FUCHS - Rectangular inductive proximity sensor

Image
Part Number
Description
General specifications Switching element function NO/NC programmable Rated operating distance 20 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater or
General specifications Switching element function NPN NO Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function PNP NO Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 5 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function PNP NO Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function PNP NO Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function PNP NO Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 50 Hz Hysteresis typ. 5 % Reverse p
General specifications Switching element function PNP NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function NO contact Rated operating distance 20 mm Installation flush Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 5 ... 30 V DC Switching frequency 0 ... 30 Hz Reverse polarity protection reverse polarity tolera
General specifications Switching element function NO contact Rated operating distance 20 mm Installation flush Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 3.8 ... 30 V DC Switching frequency 0 ... 30 Hz Reverse polarity protection reverse polarity prot
General specifications Switching element function NC contact Rated operating distance 20 mm Installation flush Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 3.8 ... 30 V DC Switching frequency 0 ... 30 Hz Reverse polarity protection reverse polarity prot
General specifications Switching element function NPN NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Re
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Re
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Re
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.32 Reduction factor r 304 0.77 Reduction factor r St37 1 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 200
General specifications Switching element function NPN NO Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function PNP NO Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function PNP NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Rever
PPRL_NBB20-L3M-US-C3-V12.jpg
PPRL_NBB20-L3M-US-V12.jpg
PPRL_NBB20-L3M-US-V93.jpg
General specifications Switching element function NPN NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Re
General specifications Switching element function NPN NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.32 Reduction factor r 304 0.77 Reduction factor r St37 1 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 200
General specifications Switching element function NPN NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Re
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.32 Reduction factor r 304 0.77 Reduction factor r St37 1 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 200
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Reverse polarity protection reverse p
General specifications Switching element function NO/NC programmable Rated operating distance 20 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.85 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater or equal V2.1 Nominal ratings Op
General specifications Switching element function NPN NO Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Rever