General specifications Switching element function AC NO/NC Rated operating distance 40 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 30.6 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Voltage drop less than or equal to
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation non-flush Output polarity Safety Function Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualifi
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation non-flush Output polarity Safety Function Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 100 Hz Current consumption Measuring plate not detected min.
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 1 ... 32.4 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r St37 0 Reduction factor r Brass 1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis 3 ... 10 % Reverse po
General specifications Switching element function NPN NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 100 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function NPN NO Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 100 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function NAMUR, NC Rated operating distance 50 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 100 Hz Current consumption Measuring plate not de
General specifications Switching element function NAMUR, NC Rated operating distance 50 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 100 Hz Current consumption Measuring plate not de
General specifications Switching element function NPN NO/NC Rated operating distance 6 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.8 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection r
General specifications Switching element function PNP NO/NC Rated operating distance 6 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.8 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection r
General specifications Switching element function NPN NO Rated operating distance 6 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.8 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection reve
General specifications Switching element function PNP NO Rated operating distance 6 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.8 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection reve
General specifications Switching element function PNP NO Rated operating distance 6 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.8 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection reve
General specifications Switching element function PNP NO Rated operating distance 6 mm Installation flush Output polarity switched high Assured operating distance 0 ... 4.8 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 500 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protecti
General specifications Switching element function NAMUR, NC Rated operating distance 6 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 4.8 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 5000 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity pr
General specifications Switching element function NAMUR, NC Rated operating distance 6 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 4.8 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 5000 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 60 mm Installation non-flush Output polarity switched high Assured operating distance 0 ... 48.6 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Adjustment aid LED, green/red Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 20 Hz Hysteresis 3 ... 15 t
General specifications Switching element function NAMUR, NO Rated operating distance 6 mm Installation flush Output polarity Safety Function Assured operating distance 0 ... 4.86 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 0 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 100 Hz Current consumption Measuring plate not dete
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity switched high Assured operating distance 0 ... 16.2 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis 3 ... 15 % Re
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity switched high Assured operating distance 0 ... 16.2 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis 3 ... 15 % Re
General specifications Switching element function PNP NO Rated operating distance 20 mm Installation flush Output polarity switched high Assured operating distance 0 ... 16.2 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis 3 ... 15 % Rever
General specifications Switching element function PNP NO Rated operating distance 20 mm Installation flush Output polarity switched high Assured operating distance 0 ... 16.2 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis 3 ... 15 % Rever
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity switched high Assured operating distance 0 ... 16.2 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis 3 ... 15 % Re
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush Output polarity switched high Assured operating distance 0 ... 16.2 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis 3 ... 15 % Re
General specifications Switching element function PNP NO Rated operating distance 20 mm Installation flush Output polarity switched high Assured operating distance 0 ... 16.2 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 100 Hz Hysteresis 3 ... 15 % Reverse
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation flush Output polarity switched high Assured operating distance 0 ... 40.5 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1 Hz Hysteresis typ. 3 % Revers
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity
General specifications Switching element function PNP NO Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1 Hz Hysteresis typ. 3 % Reverse polarity pro
General specifications Switching element function PNP NO Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity pr
General specifications Switching element function PNP NO/NC Rated operating distance 35 mm Installation non-flush Output polarity switched high Assured operating distance 0 ... 28.35 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r 304 1 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis 3 ... 15 %