General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 3 V Operating current 0 ..
General specifications Switching element function PNP NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection rev
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 250 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 3000 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polari
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation non-flush Output polarity Selective Assured operating distance 0 ... 12.15 mm Reduction factor r Al 1/0 Reduction factor r Cu 1/0 Reduction factor r St37 0/1 Reduction factor r Brass 1/0 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 100 Hz Reverse polarity protec
General specifications Switching element function PNP NO contact Frequency range 0.1 ... 1 Hz , adjustable Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 15 ... 60 V DC Reverse polarity protection reverse polarity prote
General specifications Switching element function PNP NO contact Frequency range 1 ... 10 Hz , adjustable Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 15 ... 60 V DC Reverse polarity protection reverse polarity protec
General specifications Switching element function PNP NO contact Frequency range 10 ... 100 Hz , adjustable Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 15 ... 60 V DC Reverse polarity protection reverse polarity prot
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 150 Hz Current consumption Measuring plate not detected min. 3 mA Mea
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than or e
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Voltage drop less than or equal to 7
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than or equal
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Operating voltage AC 20 ... 253 V 1) Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than o
General specifications Switching element function AC NO Rated operating distance 15 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than or
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Voltage drop less than or equal t
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.36 Reduction factor r 304 0.73 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection yes
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.36 Reduction factor r 304 0.73 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection yes
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.36 Reduction factor r 304 0.73 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection yes
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection rev
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity Safety Function Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 150 Hz Current consumption Measuring plate
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity Safety Function Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 150 Hz Current consumption Measuring plate
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 1000 Hz Hysteresis 0.01 ... 0.1 mm Suitable for 2:1 techn
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 1000 Hz Hysteresis typ. % Suitable for 2:1 technology ye
General specifications Switching element function NAMUR, NC Rated operating distance 20 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 150 Hz Current consumption Measuring plate not de
General specifications Switching element function AC NO/NC Rated operating distance 20 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than o
General specifications Switching element function AC NO/NC Rated operating distance 20 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Voltage drop less than or equal to
General specifications Switching element function AC NO/NC Rated operating distance 20 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than or equa
General specifications Switching element function NAMUR, NC Rated operating distance 20 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 150 Hz Current consumption Measuring plate not de
General specifications Switching element function AC NO/NC Rated operating distance 20 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Voltage drop less than or equal to
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation non-flush Output polarity DC Assured operating distance 1 ... 16.2 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r St37 0 Reduction factor r Brass 1 (Minimum distance: 2 mm) Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis