General specifications Switching element function NO/NC programmable Rated operating distance 40 mm Installation non-flush Output polarity AS-Interface Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Slave type Standard slave AS-Interface specification V2.1 Required master specification greater or equal V2.1 Nominal ratin
General specifications Switching element function NO/NC programmable Rated operating distance 40 mm Installation non-flush Output polarity AS-Interface Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater or equal V2.1 Nominal ratings
General specifications Switching element function NPN NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.28 Reduction factor r 304 0.75 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis typ. 5 % Re
General specifications Switching element function PNP NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.31 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 5 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function PNP NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis typ. 5 % R
General specifications Switching element function PNP NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis typ. 5 % R
General specifications Switching element function PNP NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.31 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 50 Hz Hysteresis typ. 5 % Revers
General specifications Switching element function PNP NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.28 Reduction factor r 304 0.75 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis typ. 5 % Re
General specifications Switching element function NO contact Rated operating distance 40 mm Installation non-flush Assured operating distance 0 ... 32.4 mm ( -25 ... 60 °C (-13 ... 140 °F) 0 ... 30 mm ( 60 ... 70 °C (140 ... 158 °F) Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.75 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 5 ... 30 V DC Sw
General specifications Switching element function NO contact Rated operating distance 40 mm Installation non-flush Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.75 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 3.8 ... 30 V DC Switching frequency 0 ... 30 Hz Hysteresis typ. 5% Reverse polarity protec
General specifications Switching element function NC contact Rated operating distance 40 mm Installation non-flush Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.75 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 3.8 ... 30 V DC Switching frequency 0 ... 30 Hz Hysteresis typ. 5% Reverse polarity protec
General specifications Switching element function NPN NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.28 Reduction factor r 304 0.75 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis typ. 5 %
General specifications Switching element function NPN NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.3 Reduction factor r 304 0.81 Reduction factor r St37 1 Reduction factor r Brass 0.4 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 15
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.28 Reduction factor r 304 0.75 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.3 Reduction factor r 304 0.81 Reduction factor r St37 1 Reduction factor r Brass 0.4 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 15
General specifications Switching element function NPN NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.28 Reduction factor r 304 0.75 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis typ. 5 % Re
General specifications Switching element function PNP NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.28 Reduction factor r 304 0.75 Reduction factor r Brass 0.38 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 100 Hz Hysteresis typ. 5 % Re
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.73 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 5 Hz Hysteresis typ. 5 % R
General specifications Switching element function NPN NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.39 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 %
General specifications Switching element function NPN NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.3 Reduction factor r 304 0.81 Reduction factor r St37 1 Reduction factor r Brass 0.4 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 15
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.39 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.3 Reduction factor r 304 0.81 Reduction factor r St37 1 Reduction factor r Brass 0.4 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 15
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.39 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 250 Hz Hysteresis typ. 5 %
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.39 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 250 Hz Hysteresis typ. 5 % Re
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.39 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 %
General specifications Switching element function NO/NC programmable Rated operating distance 40 mm Installation non-flush Output polarity AS-Interface Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.85 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater or equal V2.1 Nominal ratings
General specifications Switching element function NPN NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.39 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Re
General specifications Switching element function NPN NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.3 Reduction factor r 304 0.81 Reduction factor r St37 1 Reduction factor r Brass 0.4 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 150 H
General specifications Switching element function NPN NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.31 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.39 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Rever