General specifications Switching element function DC NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 150 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse pol
General specifications Switching element function NPN NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pro
General specifications Switching element function NPN NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pro
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pro
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 10 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 7.6 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity pr
General specifications Switching element function PNP NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function AC NC Rated operating distance 10 mm Installation flush Output polarity AC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.81 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function AC NO Rated operating distance 10 mm Installation flush Output polarity AC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.81 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function AC NO Rated operating distance 10 mm Installation flush Output polarity AC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.81 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Voltage drop < 5 V (I L > 50 mA)- < 8 V (I
General specifications Switching element function DC NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function NPN NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function NPN NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 7.6 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching freq
General specifications Switching element function AC NC Rated operating distance 15 mm Installation quasi flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.43 Reduction factor r Cu 0.41 Reduction factor r 304 0.82 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 25 Hz Hysteresis typ. 5 % Short-circuit protection no Voltag
General specifications: Switching element function AC NO Rated operating distance 15 mm Installation quasi flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.43 Reduction factor r Cu 0.41 Reduction factor r 304 0.82 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 25 Hz Hysteresis typ. 5 % Short-circuit protection no Voltag
General specifications Switching element function AC NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.82 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Short-circuit protection no Voltage drop
General specifications Switching element function AC NO Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.82 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Short-circuit protection no Voltage drop
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity