General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse pol
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse pol
General specifications Switching element function NAMUR, NC Rated operating distance 50 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions A 40 mm B 150 mm F 240 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching fre
General specifications Switching element function NAMUR, NC Rated operating distance 50 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions A 40 mm B 150 mm F 240 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching fre
General specifications Switching element function NAMUR, NC Rated operating distance 50 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions A 40 mm B 150 mm F 240 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching fre
General specifications Switching element function AC NO/NC Rated operating distance 50 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 3 % Short-circuit protection no Voltage
General specifications Switching element function AC NO/NC Rated operating distance 50 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage AC 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 3 % Voltage drop less than or equal to 5
General specifications Switching element function DC NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection rev
General specifications Switching element function DC NO/NC Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection rev
General specifications Switching element function NO contact Rated operating distance 50 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection rev
General specifications Switching element function DC NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 750 Hz Hysteresis typ. 3 % Reverse polarity protection conducting
General specifications Switching element function DC NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 750 Hz Reverse polarity protection conducting Short-circuit protecti
General specifications Switching element function DC NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 750 Hz Hysteresis typ. 3 % Reverse polarity protection conducting
General specifications Switching element function DC NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching fr
General specifications Switching element function DC NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.49 Reduction factor r 304 0.74 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 750 Hz Hysteresis typ. 3 % Reverse polarity protection conducting
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity p
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function NAMUR, NC Rated operating distance 8 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity
General specifications Switching element function DC NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.5 mm Reduction factor r Al 0.44 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function DC NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.5 mm Reduction factor r Al 0.44 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function DC NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.5 mm Reduction factor r Al 0.44 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function DC NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.5 mm Reduction factor r Al 0.44 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function DC NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.5 mm Reduction factor r Al 0.44 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection rever
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection rever
General specifications Switching element function NO/NC programmable Rated operating distance 8 mm Installation non-flush Output polarity AS-Interface Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.42 Reduction factor r Cu 0.4 Reduction factor r 304 0.72 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater or equal V2.1 Nominal ratings
General specifications Switching element function NPN NO Rated operating distance 12 mm Installation quasi flush Output polarity DC Assured operating distance 0 ... 9.72 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 36 mm x 36 mm x 1 mm Reduction factor r Al 0.26 Reduction factor r Cu 0.2 Reduction factor r 304 0.63 Reduction factor r Brass 0.33 Nominal ratings In