General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse pola
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 2000 Hz Reverse polarity protection reverse polarity protected Short-cir
General specifications Switching element function NPN NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function NPN NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.2 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Operating vo
General specifications Switching element function NPN NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.2 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Operating vo
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Operating vo
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.45 Nominal ratings Operating vol
General specifications Switching element function PNP NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Reduction factor r Brass 0.45 Nominal ratings Operating vo
General specifications Switching element function NPN NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.2 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Operating vo
General specifications Switching element function PNP NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Reduction factor r Brass 0.45 Nominal ratings Operating vo
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Operating vol
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Reduction factor r Brass 0.45 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Revers
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Reduction factor r Brass 0.45 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Revers
General specifications Switching element function AC/DC NO Rated operating distance 2 mm Installation flush Output polarity AC/DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 253 V AC/DC Switching frequency 0 ... 25 Hz Hysteresis typ. 5% Reverse polarity protection reverse p
General specifications Switching element function NPN NO/NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 4.75 ... 30 V DC Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 4.75 ... 30 V DC Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function PNP normally closed Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.15 Reduction factor r 304 0.7 Nominal ratings Operating voltage 4.75 ... 30 V DC Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection r
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 3000 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function NPN NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.63 Reduction factor r Brass 0.31 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 5 % Revers
General specifications Switching element function NPN normally closed Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.63 Reduction factor r Brass 0.31 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 5
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.63 Reduction factor r Brass 0.31 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 5 % Revers
General specifications Switching element function PNP normally closed Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.63 Reduction factor r Brass 0.31 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 5 %
General specifications Switching element function NPN NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function NPN NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function NPN NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-ci