General specifications: Switching element function AC NO Rated operating distance 15 mm Installation quasi flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.43 Reduction factor r Cu 0.41 Reduction factor r 304 0.82 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 25 Hz Hysteresis typ. 5 % Short-circuit protection no Voltag
General specifications Switching element function AC NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.82 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Short-circuit protection no Voltage drop
General specifications Switching element function AC NO Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.82 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Short-circuit protection no Voltage drop
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 11.4 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching freque
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NPN NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NPN NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection yes Short-circ
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 11.4 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching freque
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-circ
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NC contact Rated operating distance 15 mm Installation flush Output polarity AC/DC NC contact Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection yes Short-circuit pr
General specifications Switching element function NC contact Rated operating distance 15 mm Installation flush Output polarity AC/DC NC contact Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection yes Short-circuit pr
General specifications Switching element function AC/DC NO Rated operating distance 15 mm Installation flush Output polarity AC/DC NO contact Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection reverse polarity tolera
General specifications Switching element function AC/DC NO Rated operating distance 15 mm Installation flush Output polarity AC/DC NO contact Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection reverse polarity tolera