PEPPERL+FUCHS - Cylindrical inductive proximity sensor

Image
Part Number
Description
General specifications Switching element function NPN NO/NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarit
General specifications Switching element function NPN NO/NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarit
General specifications Switching element function PNP NO/NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarit
General specifications Switching element function PNP NO/NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarit
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Reduction factor r Brass 0.49 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polari
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Reduction factor r Brass 0.49 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse po
General specifications Switching element function NPN NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Reduction factor r Brass 0.49 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5 % Reverse p
General specifications Switching element function NPN NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Reduction factor r Brass 0.49 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5 % Reverse p
General specifications Switching element function PNP NO contact Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Reduction factor r Brass 0.49 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reve
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO contact Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 3.04 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching f
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity p
General specifications Switching element function NO contact Rated operating distance 4 mm Installation flush Output polarity AC/DC NO contact Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection yes Short-circuit protec
PPRL_no_foto.jpg
General specifications Switching element function AC/DC NO Rated operating distance 4 mm Installation flush Output polarity AC/DC NO contact Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection reverse polarity toleran
General specifications Switching element function AC NC Rated operating distance 5 mm Installation flush Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.15 Reduction factor r 304 0.62 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 25 Hz Hysteresis typ. 5 % Voltage drop less than or equal to 8 V Momentary current (20 ms, 0
General specifications Switching element function AC NO Rated operating distance 5 mm Installation flush Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.15 Reduction factor r 304 0.62 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 25 Hz Hysteresis typ. 5 % Voltage drop less than or equal to 8 V Momentary current (20 ms, 0
General specifications Switching element function NPN NO Rated operating distance 5 mm Installation flush Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.7 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Sh
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.7 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse p
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 18 mm x 18 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.15 Reduction factor r 304 0.62 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-circ
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 3.8 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.2 Reduction factor r Cu 0.15 Reduction factor r 304 0.62 Nominal ratings Operating voltage 10 ... 30 V Switching frequenc
General specifications Switching element function NPN normally closed Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-circu
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.7 Reduction factor r St37 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse po
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-circu
General specifications Switching element function DC NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.31 Reduction factor r 304 0.72 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 500 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse p
General specifications Switching element function DC NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.31 Reduction factor r 304 0.72 Nominal ratings Operating voltage 5 ... 60 V DC Switching frequency 0 ... 500 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection revers