IFM Electronic - Process sensors

Image
Part Number
Description
Link M12 Connector Technical code LR0000BSEN34AKSKG/US Level of protection IP 68- IP 69K Voltage category DC SKU UP6ZPYJ4SBAFC2 Temperature of surroundings -40...80 В°C Period of inactivity I1/I2 30 / 10 mm Degree of protection III Outputs, total ammount 2 Type of process connection 3/4" NPT Average temperature -20...100 В°C Communication int. IO-Link Working voltage, DC 18...30 V
Operating voltage: 18...30 V DC Display: Display unit: 3 x LED green , Switching status: 2 x LED yellow , Level: 4-digit alphanumeric display , Programming: 4-digit alphanumeric display Application: liquids Connection: M12 connector (according to EN 61076-2-101) Electrical design: DC PNP/NPN Probe length L: 150...2000 mm SKU 3MEY93228N04WH Output function: OUT1: normally open / closed programmable / IO-Link, OUT2: no
SKU L3JZ8DUU2XXPRU Electrical scheme PNP/NPN Link M12 Connector Communication int. IO-Link Period of inactivity I1/I2 30 / 10 mm Code LR2759 Degree of protection III Level of protection IP 68- IP 69K Technical code LR0000B-EA01AKSKG/US Working voltage, DC 18...30 V Type of process connection G 1 Aseptoflex Vario Active spectrum A L-40 mm Temperature of surroundings -40...80 В°C Lengt
Output function: normally open / closed programmable, 4...20 mA or 0...10 V Probe length L: 100...1600 mm Electrical design: DC PNP Medium temperature: 0...80 (90 < 1 h) °C Active range A: L-40 (L-60) mm Materials (wetted parts): stainless steel (303S22), probe connection: stainless steel 316L / 1.4435, PTFE, FKM, sealing: Tesnit Housing materials: stainless steel (304S15), FKM, PBT, PC, PEI, TPE / V, PTFE Shortcode:
Application: Hydrous coolants, water, media similar to water Shortcode: LR0000B-BN34AMPKG/US Electrical design: DC PNP Current rating: 200 mA Product Name: LR3300 Operating voltage: 18...30 V DC Housing materials: stainless steel (304S15), FPM (Viton), PBT, PC, PEI, TPE / V, PTFE Materials (wetted parts): stainless steel (303S22), probe connection: stainless steel 316L / 1.4435, PTFE, FPM (Viton) Output function:
Current rating: 200 mA Protection: IP 67 Ambient temperature: 0...60 °C Materials (wetted parts): stainless steel (303S22), probe connection: stainless steel 316L / 1.4435, PTFE, FKM, sealing: Tesnit Display: Display unit: 3 x LED green , Switching status: 2 x LED yellow , Level: 4-digit alphanumeric display , Programming: 4-digit alphanumeric display Housing materials: stainless steel (304S15), FKM, PBT, PC, PEI, TPE / V,
Operating voltage: 18...30 V DC Active range A: L-40 mm Housing materials: stainless steel (304S15), FPM (Viton), PBT, PC, PEI, TPE / V, PTFE Ambient temperature: 0...60 °C Probe length L: 100...1600 mm Product Name: LR7300 Current rating: 200 mA Materials (wetted parts): stainless steel (303S22), probe connection: stainless steel 316L / 1.4435, PTFE, FPM (Viton) Connection: M12 connector (according to EN 61076
Operating voltage: 18...30 V DC Application: Hydrous coolants, oils, oil-based media, water, media similar to water Protection: IP 67 Electrical design: DC PNP Medium temperature: 0...80 (90 < 1 h) °C Active range A: L-40 (L-60) mm Materials (wetted parts): stainless steel (303S22), probe connection: stainless steel 316L / 1.4435, PTFE, FKM, sealing: Tesnit Shortcode: LR0000B-BR34ASPKG/US Output function: 4 x no
Application: Hydrous coolants, oils, oil-based media, water, media similar to water Housing materials: stainless steel 316L / 1.4404, stainless steel (304S15), FKM, PBT-GF 20, PC, PEI, TPV SKU 5KHHMTEWS0YS20 Probe length L: 100...1600 mm Display: Display unit: 3 x LED green , Switching status: 4 x LED yellow , Level: 4-digit alphanumeric display , Programming: 4-digit alphanumeric display Output function: 3 x NO / NC program
Application: Hydrous coolants, water, media similar to water Current rating: 200 mA Connection: M12 connector (according to EN 61076-2-101) Ambient temperature: 0...60 °C Probe length L: 100...1600 mm Product Name: LR8300 Protection: IP 67 Materials (wetted parts): stainless steel (303S22), probe connection: stainless steel 316L / 1.4435, PTFE, FPM (Viton) Output function: 4 x normally open / closed programmabl
Ambient temperature: 0...60 °C Connection: M12 connector (according to EN 61076-2-101) Active range A: L-40 (L-60) mm Protection: IP 68 / IP 69K Materials (wetted parts): 303 / 1.4305 (V2A), probe connection: 1.4435 (V4A / 316L), PTFE, FKM, sealing: NBR-PPTA 20 Shortcode: LR0000--BR34A1DKG/US Product Name: LR9020 Operating voltage: 18...30 V DC Application: Hydrous coolants, oils, oil-based media, water, media
Voltage category DC Code LT3022 Average temperature 0...70 В°C Outputs, total ammount 2 Output of analog voltage ...10, invertible V Temperature of surroundings 0...60 В°C SKU CL80MR9KPOTWQA Active spectrum A 195 mm Level of protection IP 67 Working voltage, DC 18...30 V Period of inactivity I1/I2 53 / 16 mm Materials of wetted parts PP Output of analog current 4...20, invertible mA
Period of inactivity I1/I2 60 / 22 mm SKU 95KY2TBEW4UO9T Materials of wetted parts PP Technical code LT0472B-B-00KLPKG/US Average temperature 0...70 В°C Active spectrum A 390 mm Degree of protection III Code LT3023 Output of analog voltage ...10, invertible V Voltage category DC Temperature of surroundings 0...60 В°C Output of analog current 4...20, invertible mA Working voltage, DC 18...30 V
Communication int. IO-Link Code LT3024 Degree of protection III Electrical scheme PNP/NPN Length of Probe, L 728 mm SKU JK0UOHGDM5MIIP Technical code LT0728B-B-00KLPKG/US Temperature of surroundings 0...60 В°C Output of analog voltage ...10, invertible V Active spectrum A 585 mm Link M12 Connector Output of analog current 4...20, invertible mA Level of protection IP 67 Outputs, total a
Electrical design: DC PNP Connection: M12 connector (according to EN 61076-2-101) Display: Display unit: 4 x LED green (cm, inch, °C, °F) , Switching status: 4 x LED yellow , Measured values: 4-digit alphanumeric display , Programming: 4-digit alphanumeric display Protection: IP 67 Operating voltage: 18...30 V DC Shortcode: LT0264B-B-00KSPKG/US Housing materials: FKM, NBR, PBT, PC, PP, TPE / V, stainless steel Mater
Probe length L: 472 mm Operating voltage: 18...30 V DC Housing materials: FKM, NBR, PBT, PC, PP, TPE / V, stainless steel SKU DMUUU3WF9OXNNH Shortcode: LT0472B-B-00KSPKG/US Output function: 2 x normally open / closed programmable (level), 2 x normally open / closed programmable (temperature) Current rating: 200 mA Materials (wetted parts): PP (polypropylene) Electrical design: DC PNP Ambient temperature: 0...6
Product Name: LT8024 Probe length L: 728 mm Application: oils Output function: 2 x normally open / closed programmable (level), 2 x normally open / closed programmable (temperature) Materials (wetted parts): PP (polypropylene) Protection: IP 67 Active range A: 585 mm Ambient temperature: 0...60 °C SKU THGTKRNVOW35DI Current rating: 200 mA Operating voltage: 18...30 V DC Electrical design: DC PNP
Description: LK0264B-B-00KQPKG/US Series: efe160, RG4
Description: LT0264B-B-00KSPKG/US Series: efe160, RG4
Description: LK0264B-B-00KVPKG/US Series: efe160, RG4
Description: LT0472B-B-00KSPKG/US Series: efe160, RGN
Description: LK0472B-B-00KVPKG/US Series: efe160, RG4
Description: LT0472B-B-00KKPKG/US /V Series: efe160, RG4
Description: LR0000B-BR34ASPKG/US Series: efe160, RG4
Description: LMACE-A12E-QSKG-2/US Series: efe160, RG4
Description: LMCCE-A12E-QSKG-2/US Series: efe160, RG4
Description: LMACE-A12E-QSKG-0/US Series: efe160, RG4
Temperature of surroundings -20...85 В°C Communication int. IO-Link Voltage category DC Applying Liquids Link M12 Connector Level of protection IP 68- IP 69K Type of process connection G 1/2 external thread Degree of protection III Electrical scheme PNP/NPN Working voltage, DC 18...30 V Type of output signal switching signal- IO-Link SKU EOZKJ0PC72AF75 Average temperature -20...100 В°C
Description: LR0000--BR34A1DKG/US Series: efe160, RG4
Description: LR0240B-BR34ASPKG/US Series: efe160, RG4
Menu
Mail Us
enquiry@onstocktrading.com