Danfoss Drives - VLT FC102 HVAC

Image
Part Number
Description
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® HVAC Drive SERIES (102) HVAC Advanced version POWER RATING (N132) 132 KW / 200 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E20) IP20 / Chassis RFI FILTER (H4) RFI class A1 (C2) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS OPTION
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® HVAC Drive SERIES (102) HVAC Advanced version POWER RATING (N132) 132 KW / 200 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E20) IP20 / Chassis RFI FILTER (H2) RFI Class A2 (C3) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS OPTION
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® HVAC Drive SERIES (102) HVAC Advanced version POWER RATING (N110) 110 KW / 150 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E54) IP54 / Type 12 RFI FILTER (H2) RFI Class A2 (C3) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS OPTION
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® HVAC Drive SERIES (102) HVAC Advanced version POWER RATING (N110) 110 KW / 150 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E54) IP54 / Type 12 RFI FILTER (H2) RFI Class A2 (C3) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS OPTION
Product Details 134N2910 VLT HVAC Drive FC 102 Danfoss VLT HVAC Drive FC-102 Drive is dedicated to ventilation, heating, and refrigeration applications. With a wide range of powerful standard and optional features, the Drive provides the lowest overall cost of ownership. Characteristic Value Product Group (FC-) VLT HVAC Drive FC- Series 102 Power Rating (N200) 200 KW / 300 HP Phase (T) Three phase
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (MCD) Soft Starter MCD SERIES (202) 202 Series POWER RATING (055) 55 kW 100A:4-6: 594 PHASE (T) Three phase MAINS VOLTAGE (6) 200-575 VAC CONTROL SUPPLY VOLTAGE (CV1) 24 VAC/VDC FRAME SIZE (B) B-Frame TYPECODE MCD202055T6CV1 PRODUCT CATALOG NO VIEW ORIGINAL PRODUCT MATRIX (STD) Standard Drive VENDOR REGION Cannot Determine R
Code No. 175U3345 Name MCE101A72R0P680RE54CAW EAN 5710107613434 Net Weight 3.900 KG Gross Weight 3.900 KG
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® AQUA Drive SERIES (202) Advanced version POWER RATING (P55K) 55 KW / 75 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E55) IP55 / Type 12 RFI FILTER (H1) RFI Class A1/B (C1) BRAKE - SAFE STOP (U) Brake chopper + Safe stop LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS OPT
Product Details  –  131B6963  VLT HVAC Drive FC 102 Danfoss VLT HVAC Drive FC-102 Drive is dedicated to ventilation, heating, and refrigeration applications. With a wide range of powerful standard and optional features, the Drive provides the lowest overall cost of ownership. Characteristic Value Product View (Switch) Global (Standard) Product Group (FC-) VLT HVAC Drive FC- Series 102 P
Code No. 130B7335 Name MCC101A4K5T7E00B EAN 5710107949199 Net Weight 7.500 KG Gross Weight 8.320 KG
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® HVAC Drive SERIES (102) HVAC Advanced version POWER RATING (N132) 132 KW / 200 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E54) IP54 / Type 12 RFI FILTER (H4) RFI class A1 (C2) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS OPTION
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® HVAC Drive SERIES (102) HVAC Advanced version POWER RATING (N200) 200 KW / 300 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E54) IP54 / Type 12 RFI FILTER (H4) RFI class A1 (C2) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS OPTION
Product Details  –  134F7184  VLT HVAC Drive FC 102 Danfoss VLT HVAC Drive FC-102 Drive is dedicated to ventilation, heating, and refrigeration applications. With a wide range of powerful standard and optional features, the Drive provides the lowest overall cost of ownership. Characteristic Value Product View (Switch) Global (Standard) Product Group (FC-) VLT HVAC Drive FC- Series 102 P
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® HVAC Drive SERIES (102) HVAC Advanced version POWER RATING (P200) 200 KW / 300 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E54) IP54 / Type 12 RFI FILTER LHD - AAF006 filter + A2 RFI BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS O
Code No. 175U3451 Name MCE101A80R0P570RE65TAW EAN 5710107612833 Net Weight 4.000 KG Gross Weight 4.000 KG
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® AutomationDrive SERIES (302) AutomationDrive Advanced POWER RATING (P3K0) 3.0 KW / 4.0 HP PHASE (T) Three phase MAINS VOLTAGE (5) 380 - 500 VAC ENCLOSURE (E55) IP55 / Type 12 RFI FILTER (H1) RFI Class A1/B (C1) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (X) Not coated PCB
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® HVAC Drive SERIES (102) HVAC Advanced version POWER RATING (P45K) 45 KW / 60 HP PHASE (T) Three phase MAINS VOLTAGE (7) 525 - 690 VAC * POSSIBLE RATING ISSUE Possible Rating Issue: ENCLOSURE (E5D) IP54/Type 12 -D1 frame RFI FILTER (H6) RFI filter for Maritime BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical L
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® AQUA Drive SERIES (202) Advanced version POWER RATING (N132) 132 KW / 200 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E54) IP54 / Type 12 RFI FILTER (H2) RFI Class A2 (C3) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS OPTION (X)
Code No. 130B1414 Name Mounting Kit f. C Option , 60mm, B3 EAN 5710107610495 Net Weight 1.300 KG Gross Weight 1.300 KG
Code No. 130B4598 Name Weather shield f. outdoor instl A4 to B2 EAN 5710107608508 Net Weight 2.450 KG Gross Weight 2.450 KG
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® HVAC Drive SERIES (102) HVAC Advanced version POWER RATING (P500) 500 KW / 650 HP PHASE (T) Three phase MAINS VOLTAGE (4) 380 - 480 VAC ENCLOSURE (E54) IP54 / Type 12 RFI FILTER (H2) RFI Class A2 (C3) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel COATING PCB (C) Coated PCB MAINS OPTION
CHARACTERISTIC VALUE PRODUCT VIEW (SWITCH) Global (Standard) PRODUCT GROUP (FC-) VLT® AQUA Drive SERIES (202) Advanced version POWER RATING (N200) 200 KW / 300 HP PHASE (T) Three phase MAINS VOLTAGE (7) 525 - 690 VAC * POSSIBLE RATING ISSUE Possible Rating Issue: ENCLOSURE (E21) IP21 / Type 1 RFI FILTER (H2) RFI Class A2 (C3) BRAKE - SAFE STOP (X) No brake chopper LCP (G) Graphical Loc. Cont. Panel
Code No. 175U3332 Name MCE101A3R50P2K20E54CAW EAN 5710107613564 Net Weight 4.000 KG Gross Weight 4.000 KG
Menu
Mail Us
enquiry@onstocktrading.com