manufacter SKU MHGP 100 - HDmag Resistance IEC 60068-2-6 Vibration 30 g, 55-2000 Hz IEC 60068-2-27 Shock 300 g, 2 ms Bandwidth 400 kHz (-3 dB) Emitted interference EN 61000-6-3 Voltage supply 4.5...30 VDC Sensor head FPGA signal processing Consumption w/o load ≤160 mA Size (flange) ø99,9 mm Axial tolerance ±3 mm (wheel/head) Interference immunity EN 61000-6-2 MHGP 100 - HDmag output signals A+, B+, R+, A-, B-, R- Operating temperature -20...+85 °C Reference signal Zero pulse, width 90° Radial tolerance 0.1...2.2 mm (wheel/head) Sinewave cycles per turn 64...8192 Phase shift 90° ±10° Phase shift 90° ±5° Sensing method Magnetic Operating speed ≤8000 rpm Output stages SinCos 1 Vpp Reference signal Zero pulse, width 90° Shaft type ø16...80 mm (through hollow shaft) Consumption w/o load ≤160 mA Protection DIN EN 60529 IP 67 (head) IP 68 (wheel) MHGP 100 - HDmag output signals A+, B+, R+, A-, B-, R- Scan ratio 40...60 % Sensing method Magnetic Pulses per revolution 64...131072 Approval CE DC offset ≤20 mV Output frequency ≤2 MHz Difference of SinCos amplitude ≤20 mV Output stages HTL TTL/RS422 Accuracy of magnetic measure ±300 ' Harmonics typ. -40 dB Voltage supply 4.5...30 VDC Connection Flange connector M23, 12-pin