Specification: Part Number 6047589 Storage and transport temperature: -40 °C ... 85 °C Vibration resistance according to IEC 60751: 3 g Wetted parts: stainless steel 1.4435 (316L), Ra ≤ 0.8 µm Response time: Response time t50: ≤ 3.3 s response time t90: ≤ 9.7 s Output signal: Pt100, 4-wire Transmitter accuracy: ≤ ± 0.2 % of span Accuracy of sensor element: Class A according to IEC 60751 Electrical safety: Dielectric strength: 500 V AC Protection class: III Transmitter linearity: ≤ ± 0.1 % of span Measuring range: -50 °C ... 150 °C Insertion length/diameter of probe: 100 mm / 6 mm Protection class III: + Pressure resistance: max. 16 bar Electrical connection/enclosure rating : Round connector M12 x 1, 4-pin / IP 68 and IP 69K Process connection: Tri-clamp 1'', 1 ½'' Shock resistance: According to IEC 60751 Measuring current: 0.3 mA ... 1 mA Sensor element: Pt100 Relative humidity: ≤ 95 % Housing material: Stainless steel 1.4571 (316Ti) Ambient temperature: -40 °C ... 85 °C